logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IH16I / 1756IH16I

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IH16I / 1756IH16I

China Allen Bradley PLC 1756-IH16I / 1756IH16I supplier
Allen Bradley PLC 1756-IH16I / 1756IH16I supplier Allen Bradley PLC 1756-IH16I / 1756IH16I supplier Allen Bradley PLC 1756-IH16I / 1756IH16I supplier Allen Bradley PLC 1756-IH16I / 1756IH16I supplier Allen Bradley PLC 1756-IH16I / 1756IH16I supplier

Large Image :  Allen Bradley PLC 1756-IH16I / 1756IH16I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IH16I / 1756IH16I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $365.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IH16I technical data PDF download 1756-IH16I ControlLogix 16 Point 90-146V DC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IH16I (also written 1756IH16I) is the isolated high-voltage DC input module: 90...146 V DC, 1 mA at 90 V and 3 mA at 146 V per input, backplane load 125 mA at 5.1 V DC and 3 mA at 24 V DC (1756-IN062).

The published rating is not a single number, and this is the module where that matters most. The same table states: 90...146 V DC with 12 channels on at 50 °C, 90...132 V DC with 14 channels on at 55 °C, 90...125 V DC with 16 channels on at 60 °C, and 90...146 V DC with 16 channels on at 30 °C. Both the top of the voltage range and the number of channels that may be on move with the ambient temperature.

In practice that means an enclosure running at 60 °C cannot present 140 V to all 16 inputs. A design that quotes '90...146 V DC, 16 points' and installs the panel in a hot cabinet is quoting the 30 °C row.

Isolation is 250 V continuous basic from inputs to backplane and 250 V basic input-to-input — the isolated variant, for 110 V DC control circuits where each channel may come from a different source.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IH16I
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IH16I module product photograph 1756-IH16I terminal side product photograph 1756-IH16I module view product photograph

Where the module sits in a typical system

The module is for 110 V DC control circuits — older DC auxiliaries, trip and close circuits, and plant where 110 V DC is the station battery voltage. It reads those signals directly into the ControlLogix rack.

Because every channel is isolated, it suits circuits fed from different sources: several battery sections, or equipment from different suppliers each with its own 110 V DC supply.

The derating table makes it a documentation item as much as a hardware item: the panel schedule has to state which row applies, and the cabinet temperature has to be measured, not assumed.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Channels on derates too  12 channels at 146 V/50 °C, 14 at 132 V/55 °C, 16 at 125 V/60 °C. Count how many inputs are actually energised continuously.
 Check 3  1 mA at 90 V, 3 mA at 146 V  The input current is voltage-dependent, so the field burden rises with the applied voltage.
 Check 4  Input-to-input isolation  250 V basic between inputs as well as to the backplane — the reason to choose this rather than a group-isolated module.
 Check 5  125 mA backplane  Modest compared with the ISOE variants, but still counted per module in a full chassis.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The group-isolated wide-window module is 1756-IB16ISOE: 10...55 V DC, 5.1 mA, 320 mA backplane.

The sequence-of-events high-voltage module is 1756-IH16ISOE: 90...140 V DC, 1.15...1.85 mA, 275 mA backplane.

For 30...60 V DC circuits the module is 1756-IC16, and for 24 V DC it is 1756-IB16.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IH16I ControlLogix 16 Point 90-146V DC Input | Rockwell

What is the 1756-IH16I?

A 16-point isolated high-voltage DC input module, 90...146 V DC, with input current of 1 mA at 90 V and 3 mA at 146 V.

Why does the specification list several voltage ranges?

The published table derates both voltage and channels-on with ambient temperature: 90...146 V DC at 30 °C, 90...146 V DC with 12 channels at 50 °C, 90...132 V DC with 14 channels at 55 °C and 90...125 V DC with 16 channels at 60 °C.

What is the backplane current?

125 mA at 5.1 V DC and 3 mA at 24 V DC.

What isolation does it provide?

250 V continuous basic inputs-to-backplane and 250 V basic input-to-input.

Can all 16 inputs be on at 60 °C with 146 V?

No. At 60 °C the published top of the range is 125 V DC for 16 channels on.

What is the input current per point?

1 mA at 90 V DC and 3 mA at 146 V DC.

Is there a harsh-environment version?

Yes — 1756-IH16IK, the conformal-coated variant in the same publication.

What documents cover it?

1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IH16I. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)