Product Details:
Payment & Shipping Terms:
|
The 1756-A4LXT (also written 1756A4LXT) is the four-slot ControlLogix-XT chassis: the smallest backplane in the extreme-temperature family, conformally coated for ISA G3 environments, and rated for -25…+60 °C surrounding air.
Published figures are 4 slots, 10 A chassis and 6 A per slot at 5.1 V DC, 2 A / 2 A at 24 V DC, 4 A / 4 A at 3.3 V DC, 1.5 A at 1.2 V DC, 3.7 W maximum chassis dissipation, a minimum cabinet of 50.8 x 50.8 x 20.3 cm, and 0.75 kg approximate weight (1756-TD006). Horizontal mounting only, open-style, panel located.
1756-A4LXT/B |
4 slots, 50.8 x 50.8 x 20.3 cm, -25…+60 °C, 10 A at 5.1 V DC |
In stock |
1756-A5XT/B |
5 slots, 50.8 x 76.2 x 20.3 cm, -25…+70 °C, 10 A at 5.1 V DC |
In stock |
1756-A7LXT/B |
7 slots, 50.8 x 60.9 x 20.3 cm, -25…+60 °C, 10 A at 5.1 V DC |
In stock |
1756-A7XT/B |
7 slots, 50.8 x 60.9 x 20.3 cm, -25…+70 °C, 10 A at 5.1 V DC |
In stock |
1756-A7XT/C |
7 slots, -25…+70 °C, 15 A at 5.1 V DC, Series C |
In stock |
1756-A10XT/C |
10 slots, 50.8 x 85.75 x 20.3 cm, -25…+70 °C, 15 A at 5.1 V DC |
In stock |
Application |
Chassis / backplane |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-A4LXT |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
Open chassis, conformally coated (XT) |
Interface |
1756-A4LXT |
Mounting |
Horizontal only, panel located |
Number Of Channels |
1756-A4LXT |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Chassis |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN005 (chassis installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Four slots is the size of a remote or satellite panel: a controller, a communication module and two I/O modules, or three I/O modules without a controller where the rack is an I/O drop. In an XT installation that usually means an unheated outdoor enclosure or a cold-store annex where the main rack cannot reach.
The 5.1 V budget is the design constraint, not the slot count. Ten amps total with six per slot is generous for four modules, but the XT power supplies that fit this chassis publish 42 W (1756-PAXT) or 52 W (1756-PBXT) output, so the supply and the module sum have to be checked together.
A chassis has no indicators; its limits are the numbers that decide whether the rack can carry the modules planned for it. Every row below is quoted from the chassis specification 1756-TD006.
| Indicator | State | Meaning and first action |
| Backplane current at 5.1 V DC | 10 A / 6 A | Chassis total / per-slot maximum. Sum the 5.1 V current of every module against this figure before the layout is fixed. |
| Backplane current at 24 V DC | 2 A / 2 A | Chassis total / per-slot maximum, for modules that take their 24 V from the backplane. |
| Backplane current at 3.3 V DC | 4 A / 4 A | Chassis total / per-slot maximum, common to the whole XT family. |
| Backplane current at 1.2 V DC | 1.5 A / – | Chassis total, with no per-slot limit published. |
| Power dissipation | See the specification table | The chassis itself dissipates 3.7 W to 5.0 W depending on size; it adds to the enclosure thermal load. |
| Operating temperature | -25…+60 °C (-13…+140 °F) | The surrounding-air rating of this chassis. Every module in the rack has to share it or the assembly drops to the lower figure. |
| Mounting | Horizontal only | Panel mount, minimum cabinet depth 20.3 cm; the XT chassis is conformally coated for ISA G3 environments. |
| Earth grounding | 8 AWG functional / 14 AWG protective | Copper wire rated 90 °C or greater; the coating does not replace the earth connection. |
Slot counts, backplane current, enclosure sizes and environmental ratings per Rockwell publication 1756-TD006F-EN-E (1756 ControlLogix Chassis Specifications) and 1756-IN050.
Where the panel no longer needs the extreme range, the standard 1756-A4 chassis covers the same four slots at 0…60 °C in a smaller temperature envelope; where the slot count grows, the 1756-A5XT and 1756-A7LXT add slots in the same XT family.
The XT chassis is conformally coated; a standard chassis is not. Replacing one with the other changes the environmental qualification of the whole assembly, not only the price.
How many slots does the 1756-A4LXT have?
Four slots, with 10 A chassis and 6 A per slot at 5.1 V DC (1756-TD006).
What temperature is it rated for?
-25…+60 °C surrounding air, against -25…+70 °C on the 1756-A5XT and 1756-A7XT; storage -40…+85 °C, 5…95% RH noncondensing.
What backplane current is available?
10 A at 5.1 V DC (6 A per slot), 2 A at 24 V DC (2 A per slot), 4 A at 3.3 V DC (4 A per slot) and 1.5 A at 1.2 V DC.
How much does the chassis itself dissipate?
3.7 W maximum, the lowest in the XT family; the A7LXT publishes 4.1 W, the A5XT and A7XT/B 4.4 W, the A7XT/C 4.5 W and the A10XT/C 5.0 W.
What cabinet size is needed?
Minimum 50.8 x 50.8 x 20.3 cm (20 x 20 x 8 in.), horizontal mounting only, panel located.
What is the chassis weight?
0.75 kg (1.7 lb) approximately, the same as the standard 1756-A4.
What grounding wire is specified?
8.3 mm² (8 AWG) copper rated 90 °C or greater for functional earth, 2.1 mm² (14 AWG) for protective earth.
Which certifications does it carry?
UL Listed (E65584), UL Class I Division 2 (E194810), FM Approved, CE to EN 61326-1 / 61000-6-2 / 61000-6-4 / 61131-2, RCM, ATEX Ex nA IIC T5 Gc X, IECEx, KC and EAC, when marked.
Data sources. Technical values on this page come from Rockwell publications 1756-TD006 (1756 ControlLogix Chassis Specifications) and 1756-IN005 (ControlLogix chassis installation instructions) and the manufacturer's product page for 1756-A4LXT. Values re-checked 16 November 2026.