logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-A4LXT / 1756A4LXT

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-A4LXT / 1756A4LXT

China Allen Bradley PLC 1756-A4LXT / 1756A4LXT supplier
Allen Bradley PLC 1756-A4LXT / 1756A4LXT supplier Allen Bradley PLC 1756-A4LXT / 1756A4LXT supplier Allen Bradley PLC 1756-A4LXT / 1756A4LXT supplier Allen Bradley PLC 1756-A4LXT / 1756A4LXT supplier Allen Bradley PLC 1756-A4LXT / 1756A4LXT supplier

Large Image :  Allen Bradley PLC 1756-A4LXT / 1756A4LXT

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-A4LXT / 1756A4LXT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $245.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-A4LXT technical data PDF download ControlLogix-XT 1756-A4LXT / 1756A4LXT 4-Slot Chassis

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-A4LXT (also written 1756A4LXT) is the four-slot ControlLogix-XT chassis: the smallest backplane in the extreme-temperature family, conformally coated for ISA G3 environments, and rated for -25…+60 °C surrounding air.

Published figures are 4 slots, 10 A chassis and 6 A per slot at 5.1 V DC, 2 A / 2 A at 24 V DC, 4 A / 4 A at 3.3 V DC, 1.5 A at 1.2 V DC, 3.7 W maximum chassis dissipation, a minimum cabinet of 50.8 x 50.8 x 20.3 cm, and 0.75 kg approximate weight (1756-TD006). Horizontal mounting only, open-style, panel located.

1756-A4LXT/B
4 slots, 50.8 x 50.8 x 20.3 cm, -25…+60 °C, 10 A at 5.1 V DC
In stock
1756-A5XT/B
5 slots, 50.8 x 76.2 x 20.3 cm, -25…+70 °C, 10 A at 5.1 V DC
In stock
1756-A7LXT/B
7 slots, 50.8 x 60.9 x 20.3 cm, -25…+60 °C, 10 A at 5.1 V DC
In stock
1756-A7XT/B
7 slots, 50.8 x 60.9 x 20.3 cm, -25…+70 °C, 10 A at 5.1 V DC
In stock
1756-A7XT/C
7 slots, -25…+70 °C, 15 A at 5.1 V DC, Series C
In stock
1756-A10XT/C
10 slots, 50.8 x 85.75 x 20.3 cm, -25…+70 °C, 15 A at 5.1 V DC
In stock

 Application
 Chassis / backplane
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-A4LXT
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 Open chassis, conformally coated (XT)
 Interface
 1756-A4LXT
 Mounting
 Horizontal only, panel located
 Number Of Channels
 1756-A4LXT
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Chassis
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN005 (chassis installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-A4LXT chassis product photograph 1756-A4LXT chassis, second view product photograph 1756-A4LXT chassis, third view product photograph

Where this chassis sits in a typical system

Four slots is the size of a remote or satellite panel: a controller, a communication module and two I/O modules, or three I/O modules without a controller where the rack is an I/O drop. In an XT installation that usually means an unheated outdoor enclosure or a cold-store annex where the main rack cannot reach.

The 5.1 V budget is the design constraint, not the slot count. Ten amps total with six per slot is generous for four modules, but the XT power supplies that fit this chassis publish 42 W (1756-PAXT) or 52 W (1756-PBXT) output, so the supply and the module sum have to be checked together.

Commissioning in four steps

  1. Mount horizontally only. The XT chassis is a back-panel part; it is not rated for vertical mounting, and the minimum cabinet depth of 20.3 cm applies to every size in the family.
  2. Size the cabinet before the modules: the published minimum enclosure runs from 50.8 x 50.8 x 20.3 cm on the 1756-A4LXT to 50.8 x 85.75 x 20.3 cm on the 1756-A10XT, and the XT power supply sits on the left of the chassis.
  3. Budget the backplane per rail, not per rack: the 1756-A4LXT, A7LXT, A5XT and A7XT/B publish 10 A chassis / 6 A per slot at 5.1 V DC and 2 A at 24 V DC, while the A7XT/C and A10XT/C publish 15 A / 6 A and 2.8 A / 2.8 A.
  4. Ground the chassis with the published wire sizes: 8.3 mm² (8 AWG) copper for functional earth and 2.1 mm² (14 AWG) for protective earth, both rated 90 °C or greater. The XT chassis is conformally coated for ISA G3 environments, and the coating does not replace the earth connection.

Limits: slots, backplane current and temperature

A chassis has no indicators; its limits are the numbers that decide whether the rack can carry the modules planned for it. Every row below is quoted from the chassis specification 1756-TD006.

 Indicator  State  Meaning and first action
 Backplane current at 5.1 V DC  10 A / 6 A  Chassis total / per-slot maximum. Sum the 5.1 V current of every module against this figure before the layout is fixed.
 Backplane current at 24 V DC  2 A / 2 A  Chassis total / per-slot maximum, for modules that take their 24 V from the backplane.
 Backplane current at 3.3 V DC  4 A / 4 A  Chassis total / per-slot maximum, common to the whole XT family.
 Backplane current at 1.2 V DC  1.5 A / –  Chassis total, with no per-slot limit published.
 Power dissipation  See the specification table  The chassis itself dissipates 3.7 W to 5.0 W depending on size; it adds to the enclosure thermal load.
 Operating temperature  -25…+60 °C (-13…+140 °F)  The surrounding-air rating of this chassis. Every module in the rack has to share it or the assembly drops to the lower figure.
 Mounting  Horizontal only  Panel mount, minimum cabinet depth 20.3 cm; the XT chassis is conformally coated for ISA G3 environments.
 Earth grounding  8 AWG functional / 14 AWG protective  Copper wire rated 90 °C or greater; the coating does not replace the earth connection.

Slot counts, backplane current, enclosure sizes and environmental ratings per Rockwell publication 1756-TD006F-EN-E (1756 ControlLogix Chassis Specifications) and 1756-IN050.

Replacing a chassis inside an existing XT rack

Where the panel no longer needs the extreme range, the standard 1756-A4 chassis covers the same four slots at 0…60 °C in a smaller temperature envelope; where the slot count grows, the 1756-A5XT and 1756-A7LXT add slots in the same XT family.

The XT chassis is conformally coated; a standard chassis is not. Replacing one with the other changes the environmental qualification of the whole assembly, not only the price.

Which ControlLogix-XT chassis to specify

  • 1756-A4LXT — 4 slots, 10 A at 5.1 V DC backplane budget, -25…+60 °C. The smallest XT rack, for a remote panel with a controller and a few modules.
  • 1756-A5XT — 5 slots, -25…+70 °C. The odd slot count that fits a controller, a communication module and three I/O modules without leaving an empty slot.
  • 1756-A7LXT — 7 slots, 10 A at 5.1 V DC, -25…+60 °C.
  • 1756-A7XT — 7 slots, -25…+70 °C, 10 A at 5.1 V DC in Series B and 15 A in Series C.
  • 1756-A10XT — 10 slots, -25…+70 °C, 15 A at 5.1 V DC, Series C only.

FAQ — ControlLogix-XT 1756-A4LXT / 1756A4LXT 4-Slot Chassis

How many slots does the 1756-A4LXT have?

Four slots, with 10 A chassis and 6 A per slot at 5.1 V DC (1756-TD006).

What temperature is it rated for?

-25…+60 °C surrounding air, against -25…+70 °C on the 1756-A5XT and 1756-A7XT; storage -40…+85 °C, 5…95% RH noncondensing.

What backplane current is available?

10 A at 5.1 V DC (6 A per slot), 2 A at 24 V DC (2 A per slot), 4 A at 3.3 V DC (4 A per slot) and 1.5 A at 1.2 V DC.

How much does the chassis itself dissipate?

3.7 W maximum, the lowest in the XT family; the A7LXT publishes 4.1 W, the A5XT and A7XT/B 4.4 W, the A7XT/C 4.5 W and the A10XT/C 5.0 W.

What cabinet size is needed?

Minimum 50.8 x 50.8 x 20.3 cm (20 x 20 x 8 in.), horizontal mounting only, panel located.

What is the chassis weight?

0.75 kg (1.7 lb) approximately, the same as the standard 1756-A4.

What grounding wire is specified?

8.3 mm² (8 AWG) copper rated 90 °C or greater for functional earth, 2.1 mm² (14 AWG) for protective earth.

Which certifications does it carry?

UL Listed (E65584), UL Class I Division 2 (E194810), FM Approved, CE to EN 61326-1 / 61000-6-2 / 61000-6-4 / 61131-2, RCM, ATEX Ex nA IIC T5 Gc X, IECEx, KC and EAC, when marked.


Data sources. Technical values on this page come from Rockwell publications 1756-TD006 (1756 ControlLogix Chassis Specifications) and 1756-IN005 (ControlLogix chassis installation instructions) and the manufacturer's product page for 1756-A4LXT. Values re-checked 16 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956