The 1756-DMF30K (also written 1756DMF30K) is the extended-protection version of the SF3000 drive module. Rockwell's selection guide defines the K designation as extended protection in harsh, corrosive environments; the module behind that designation is the drive-module design published for the 1756-DMF30.
The published specification is the family figure and does not shift with the coating: 1.35 A at 5.1 V DC and 3.0 mA at 24 V DC from the backplane, 6.96 W maximum power dissipation, 0…60 °C operating, drive comm at 62.5/125 µm glass / 820 nm / 10 Mbps and SynchLink at 200/230 µm hard-clad silica / 650 nm / 5 Mbps, each limited to 300 m with one splice or adapter and 1 m minimum.
1756-DMD30K |
Drive module, SD3000, extended protection (K) |
In stock |
1756-DMF30K |
Drive module, SF3000, extended protection (K) |
In stock |
1756-DMD30 |
Drive module, SD3000, standard protection |
In stock |
1756-DMF30 |
Drive module, SF3000, standard protection |
In stock |
1756-DMCF003 |
Drive comm fibre cable, 3 m |
In stock |
Application |
Drive control, extended protection (SF3000) |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-DMF30K |
Type |
Drive module |
Sub Brand |
ControlLogix |
Mounting |
1756 ControlLogix chassis |
Interface |
Fibre, drive comm and SynchLink |
Backplane Current |
1.35 A at 5.1 V DC, 3.0 mA at 24 V DC |
Power Dissipation |
6.96 W maximum, 23.7 BTU/hr thermal |
Operating Temperature |
0…60 °C (32…140 °F) |
Storage Temperature |
-40…85 °C (-40…185 °F) |
Relative Humidity |
5…95% non-condensing |
Shock |
30 g operating, 50 g non-operating (11 ms) |
Vibration |
2 g at 10…500 Hz, IEC 68-2-6 |
Certification |
UL Listed, SF Certified, Class I Div 2, FM, CE, N223 |
SynchLink Link |
200/230 µm HCS, 650 nm, 5 Mbps, 300 m max |
Drive Comm Link |
62.5/125 µm glass, 820 nm, 10 Mbps, 300 m max |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
SF3000 panels that need the K module are usually panels in processed-air environments: sulphur from rubber or pulp, chlorine from water treatment, salt from coastal sites. The coating is a barrier against those vapours, and it is specified at the same time as the enclosure purge, not instead of it.
The drive module is on the list because it is cabled directly to the PMI chassis inside the drive cabinet, which is the compartment where corrosive air concentrates. A standard module in that slot is the shortest-lived item in the bill of materials.
The consequence for commissioning is procedural: the coated module is handled the same way, seated the same way, and carries the same SF3000 interface panel and indicators, so nothing in the wiring changes. Only the ordering rule changes.
The K suffix changes the protection, not the specification sheet. Every electrical, fibre and environmental figure below is the published drive-module value, quoted from the installation instructions.
| Indicator | State | Meaning and first action |
| OK | Flashing green | Inhibited I/O connection; no action. |
| OK | Red | Non-recoverable fault; remove the module from service. |
| OK | Off | Module is powered down. |
| DRIVE FAULT | Red | Module is faulted; read the fault status parameters. |
| LINK SYNC | Flashing red | Two CST time masters detected; leave exactly one on the SynchLink. |
| OS OK | Off | Checksum failure; reflash the module. |
| DRIVE COMM OK | Off | DPS communication is inactive or unsynchronised; verify the cable connections. |
| LINK COMM | Off | Configured but not receiving valid SynchLink data; verify cabling, or enable the module transmitter. |
| Interface panel | SF3000 | The module carries an SF3000 interface label; the drive system behind the PMI chassis must match it. |
K-suffix meaning per Rockwell 1756-SG001; electrical, fibre and environmental figures per Rockwell 1756-IN577-EN-P and 1756-IN050.
Replace with the K part number and check the connector plating while the module is out; the usual failure mode in a corrosive cabinet is connector corrosion under the coating boundary, not a failed component.
A standard 1756-DMF30 will run in the socket, and it will also become the next fault. In a cabinet that justified the K suffix, the standard module should be treated as an emergency measure with a dated replacement plan.
If the SF3000 system is being replaced, a PowerFlex drive with an EtherNet/IP interface removes the drive module and its fibre from the cabinet, which is the cleanest exit from a corrosive-environment problem.
What does the K suffix mean on the 1756-DMF30K?
Extended protection in harsh, corrosive environments, as defined in Rockwell 1756-SG001.
Is it electrically identical to the 1756-DMF30?
Yes. The published figures are the same; the difference is the protection applied to the assembly.
What are its backplane ratings?
1.35 A at 5.1 V DC and 3.0 mA at 24 V DC, with 6.96 W maximum power dissipation and 23.7 BTU/hr thermal.
What fibre does it use?
Drive comm on 62.5/125 µm glass at 820 nm and 10 Mbps; SynchLink on 200/230 µm HCS at 650 nm and 5 Mbps.
What run length is allowed?
1 m minimum and 300 m maximum on either link, with no more than one splice or adapter.
Does the coating change the temperature range?
No. 0…60 °C operating and -40…85 °C storage remain the published limits.
Which drive system does it pair with?
The SF3000; the SD3000 uses the 1756-DMD30K.
Which certifications apply?
The drive-module certifications: UL Listed, SF Certified, Class I Division 2 (certified and FM approved), CE and N223.
Data sources. Technical values on this page come from Rockwell publications 1756-SG001 (ControlLogix System Selection Guide - K and XT catalog numbers carry extended protection in harsh, corrosive environments); 1756-IN577 (ControlLogix Drive Module installation instructions) and the manufacturer's product page for 1756-DMF30K. Values re-checked 16 November 2026.