The 1756-DMF30 (also written 1756DMF30) is the ControlLogix drive module for the SF3000 one-axis drive system. It occupies a ControlLogix chassis slot and links the controller to an individual PMI chassis and to SynchLink devices over fibre.
Its published specification is identical to the 1756-DMD30: 1.35 A at 5.1 V DC plus 3.0 mA at 24 V DC, 6.96 W maximum dissipation, 0…60 °C operating, drive comm at 62.5/125 µm glass / 820 nm / 10 Mbps and SynchLink at 200/230 µm hard-clad silica / 650 nm / 5 Mbps, both capped at 300 m with no more than one splice or adapter. What differs is the drive system behind the PMI chassis.
1756-DMD30 |
Drive module, SD3000 system, 1.35 A at 5.1 V DC |
In stock |
1756-DMF30 |
Drive module, SF3000 system, 1.35 A at 5.1 V DC |
In stock |
1756-DMCF003 |
Drive comm fibre cable, 3 m, pre-configured |
In stock |
1756-DMAF |
Adapter for existing UDC/PMI fibre cables |
In stock |
1756-SYNCH |
SynchLink module, the fibre network companion |
In stock |
Application |
Drive control and synchronisation (SF3000) |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-DMF30 |
Type |
Drive module |
Sub Brand |
ControlLogix |
Mounting |
1756 ControlLogix chassis |
Interface |
Fibre, drive comm and SynchLink |
Backplane Current |
1.35 A at 5.1 V DC, 3.0 mA at 24 V DC |
Power Dissipation |
6.96 W maximum, 23.7 BTU/hr thermal |
Operating Temperature |
0…60 °C (32…140 °F) |
Storage Temperature |
-40…85 °C (-40…185 °F) |
Relative Humidity |
5…95% non-condensing |
Shock |
30 g operating, 50 g non-operating (11 ms) |
Vibration |
2 g at 10…500 Hz, IEC 68-2-6 |
Certification |
UL Listed, SF Certified, Class I Div 2, FM, CE, N223 |
SynchLink Link |
200/230 µm HCS, 650 nm, 5 Mbps, 300 m max |
Drive Comm Link |
62.5/125 µm glass, 820 nm, 10 Mbps, 300 m max |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The SF3000 uses the same ControlLogix drive-module architecture as the SD3000, which is why the two catalogue numbers share one specification sheet. The module knows the difference, though: a DMF30 in place of a DMD30 does not synchronise.
For a panel already running SF3000 drives, this is the piece that ties the drive loop back to the controller, and the engineering effort sits in the fibre topology — cable type, length, star versus daisy chain.
The power figure is the one that bites on retrofits. 1.35 A at 5.1 V DC is a real load on a chassis that was sized for I/O, and retrofits are exactly where the budget was inherited rather than recalculated.
The module carries the OK LED plus six indicators per interface panel, and every row below is quoted from the drive module installation instructions.
| Indicator | State | Meaning and first action |
| OK | Flashing green | Inhibited I/O connection; no action. |
| OK | Red | Non-recoverable fault; remove the module from service. |
| OK | Off | Module is powered down. |
| DRIVE FAULT | Red | Module is faulted; read the fault status parameters. |
| LINK SYNC | Flashing red | Two CST time masters detected; leave exactly one on the SynchLink. |
| OS OK | Off | Checksum failure; reflash the module. |
| DRIVE COMM OK | Off | DPS communication is inactive or unsynchronised; verify the cable connections. |
| LINK COMM | Off | Configured but not receiving valid SynchLink data; verify cabling, or enable the module transmitter. |
| Interface panel | SF3000 | The module carries an SF3000 interface label; the drive system behind the PMI chassis must match it. |
Power, fibre, environmental, certification and indicator figures per Rockwell publication 1756-IN577-EN-P and 1756-IN050.
As with the DMD30 there is no catalogue successor: the drive system is the constraint, and a failed module is answered with a tested spare or with a drive-system migration.
A migration to a PowerFlex drive with an EtherNet/IP interface removes the drive module and the SynchLink network from the chassis, changing the power budget, the fibre drawing and the controller configuration at once.
Keep the pairing straight. Electrically the DMF30 and DMD30 are interchangeable on paper and incompatible in a panel, because each belongs to a different drive system.
What is the 1756-DMF30?
The ControlLogix drive module for the SF3000 one-axis drive system.
Is it electrically different from the DMD30?
No — the published figures are the same; the drive system it serves is different.
What is its backplane draw?
1.35 A at 5.1 V DC and 3.0 mA at 24 V DC, 6.96 W maximum.
What fibre does it use?
Drive comm on 62.5/125 µm glass at 820 nm and 10 Mbps; SynchLink on 200/230 µm HCS at 650 nm and 5 Mbps.
What run lengths are allowed?
1 m minimum and 300 m maximum on either link, with no more than one splice or adapter.
What are the environmental limits?
0…60 °C operating, -40…85 °C storage, 5…95% relative humidity non-condensing, 30 g shock.
Which certifications apply?
UL Listed, SF Certified, Class I Division 2 (certified and FM approved), CE and N223.
Which drive system does it pair with?
The SF3000; the SD3000 uses the 1756-DMD30.
Data sources. Technical values on this page come from Rockwell publications 1756-IN577 (ControlLogix Drive Module, catalog numbers 1756-DMD30 and 1756-DMF30, installation instructions) and the manufacturer's product page for 1756-DMF30. Values re-checked 16 November 2026.