Allen Bradley PLC 1756-CNB / 1756CNB

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-CNB / 1756CNB

China Allen Bradley PLC 1756-CNB / 1756CNB supplier
Allen Bradley PLC 1756-CNB / 1756CNB supplier Allen Bradley PLC 1756-CNB / 1756CNB supplier Allen Bradley PLC 1756-CNB / 1756CNB supplier Allen Bradley PLC 1756-CNB / 1756CNB supplier Allen Bradley PLC 1756-CNB / 1756CNB supplier

Large Image :  Allen Bradley PLC 1756-CNB / 1756CNB

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-CNB / 1756CNB

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $828.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-CNB technical data PDF download ControlLogix 1756-CNB / 1756CNB ControlNet Bridge Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-CNB (also written 1756CNB) is the smaller ControlNet bridge for the ControlLogix 1756 platform: one ControlNet BNC port at 5 Mbps, 40…48 Logix communication connections, chassis mounted and one slot wide. It is the module for a short ControlNet segment where the full 128-connection budget of the CN2 is not needed.

Table 22 publishes 40…48 Logix communication connections with 64 connections supported in total and 99 nodes on the network. Current draw is 970 mA at 5.1 V DC, dissipating 5.1 W and 17.4 BTU/hr at approximately 0.26 kg. Isolation is 30 V continuous basic insulation type tested at 500 V AC for 60 s. Operating temperature is 0…60 °C, temperature code T4, open-style, one slot wide. There is no USB port on this module — local programming goes through the controller or the network.

1756-CN2 ControlNet bridge, 1 BNC port, 128 Logix connections IN STOCK
1756-CN2R Redundant ControlNet bridge, 2 BNC ports, 128 Logix connections IN STOCK
1756-CN2RXT Redundant ControlNet bridge, -25...70 C, conformal coated IN STOCK
1756-CNB ControlNet bridge, 1 BNC port, 40...48 Logix connections IN STOCK
1756-CNBR Redundant ControlNet bridge, 2 BNC ports, 40...48 connections IN STOCK

 Application
 ControlNet
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-CNB
 Communication
 ControlNet
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1 ControlNet BNC (5 Mbps)
 Mounting
 Chassis
 Number Of Channels
 1
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix system user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-CNB product photograph product photograph 1756-CNB module product photograph 1756-CNB module, second view product photograph

Where the module sits in a typical system

The module fits the small segment: a cell with two or three I/O racks and a drive, where a 128-connection bridge would be capacity nobody uses. At 970 mA it is also the lightest ControlNet bridge in the range, which matters in a chassis that is already close to its supply rating.

Its 40…48 Logix connections are the constraint to watch. Each rack and drive connection counts, and a segment that grows past the published figure needs the CN2 or CN2R rather than a second CNB in the same chassis.

Commissioning in five steps

  1. Set the node address on the module before it joins the segment — the ControlNet address is the module's identity on the wire, and two modules at the same address will not both come online.
  2. Use 1786-RG6 quad-shield coax with the published connectors and terminators; control the trunk length and the number of taps against the ControlNet planning rules, not by eye.
  3. Insert the module in any 1756 chassis slot; the published chassis are 1756-A4, A7, A10, A13 and A17 (1756-TD003 Table 22).
  4. Add the module to the I/O configuration in Studio 5000 and schedule the network — an unscheduled ControlNet segment carries no I/O regardless of the wiring.
  5. Read the indicators at power-up: a module that shows no network activity on a scheduled, terminated segment is an addressing or cabling fault before it is a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 OK  Flashing green  Power-up self-test in progress; wait for the solid state.
 OK  Off  No chassis power at the slot, or the module failed its self-test.
 ControlNet  Green solid  Module is on the network and exchanging scheduled data.
 ControlNet  Flashing green  Connected but not scheduled, or not the keeper for the segment.
 ControlNet  Flashing red  Duplicate node address or a configuration mismatch.
 ControlNet  Off  No activity: trunk unterminated, cable open, or address not set.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix System User Manual) and 1756-IN050.

Replacing a ControlNet segment

ControlNet is a legacy network; Rockwell publishes the migration as CNET-RM001, the ControlNet to EtherNet/IP Migration Reference Manual, which moves the segment rather than exchanging one catalogue number for another.

Where a CNB is being replaced as a spare, the matching part is another CNB or a CNBR for redundancy. Where the segment itself is being retired, the EtherNet/IP budget of 128 TCP and 256 CIP connections on an EN2T is the new planning figure, and the 40…48 connections here no longer apply.

Which ControlLogix ControlNet module to specify

  • 1756-CN2 — one BNC port, 128 Logix connections, 1.1 A at 5.1 V DC, 3 mA at 24 V DC. The standard bridge for a single ControlNet segment.
  • 1756-CN2R — two BNC ports for a redundant trunk, same 128 Logix connections, 1.3 A at 5.1 V DC. Three connections are reserved for redundant control.
  • 1756-CN2RXT — the redundant module in the XT range, -25…+70 °C, 1.3 A at 5.1 V DC, wired to 1786-RG6 quad-shield coax.
  • 1756-CNB — one BNC port, 40…48 Logix connections, 970 mA at 5.1 V DC. The smaller bridge for a short segment.
  • 1756-CNBR — two BNC ports, 40…48 Logix connections, 970 mA at 5.1 V DC. Redundancy at the lower connection count.
  • 1756-EN2T / EN2TR — not ControlNet parts: the EtherNet/IP equivalent when the network itself is being replaced.

FAQ — ControlLogix 1756-CNB / 1756CNB ControlNet Bridge Module

How is the 1756-CNB different from the 1756-CN2?

The connection budget and the draw. The CNB publishes 40…48 Logix communication connections with 64 supported in total at 970 mA and 5.1 W; the CN2 publishes 128 Logix connections, 131 supported, at 1100 mA and 5.6 W (1756-TD003 Table 22). Both run ControlNet at 5 Mbps with up to 99 nodes.

What is the connection limit on this module?

40…48 Logix communication connections, with 64 connections supported in total (Table 22). Scheduled rack and drive connections on the segment come out of that figure, so the count is made when the network is scheduled.

Does it have a USB programming port?

No. Table 22 lists the USB port for the CN2 and CN2R only; the CNB and CNBR have no front USB port, so local programming is done through the controller or across the network.

What is its backplane load?

970 mA at 5.1 V DC, dissipating 5.1 W and 17.4 BTU/hr, one slot wide, approximately 0.26 kg (Table 22). It is the lowest draw of the four standard ControlNet bridges.

What are its environmental limits and certifications?

Operating 0…60 °C (Table 22); T4; open-style. Certifications per Table 6: c-UL-us UL E65584 and Class I Division 2 UL E194810, CSA LR54689C and LR69960C, CE to 2014/30/EU, RCM, ATEX II 3 G Ex ec IIC T4 Gc, UKEX UL22UKEX2604X, UKCA, IECEx UL 22.0063X, FM Class I Division 2, KC, ODVA and CCC 2020122309111998.

Which chassis accept it?

1756-A4, A7, A10, A13 or A17, in any slot (Table 22). Isolation to the network is 30 V continuous basic insulation, type tested at 500 V AC for 60 s.

Is the 1756-CNB still the right choice for a new line?

For a new installation the network decision is EtherNet/IP, not ControlNet — ControlNet is described as legacy and the migration route is CNET-RM001. The CNB remains the correct part where an existing ControlNet segment is being maintained or extended within its 40…48 connection budget.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-UM001 (ControlLogix System User Manual) and CNET-RM001 (ControlNet to EtherNet/IP Migration Reference Manual) and the manufacturer's product page for 1756-CNB. Values re-checked 15 November 2026.