Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT

China Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier
Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT supplier

Large Image :  Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-CN2RXT / 1756CN2RXT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1775.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description


1756-CN2RXT technical data PDF download ControlLogix-XT 1756-CN2RXT / 1756CN2RXT ControlNet Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-CN2RXT (also written 1756CN2RXT) is the ControlNet-XT module: two ControlNet BNC ports at 5 Mbps in a redundant configuration, conformal coated and rated -25…+70 °C, chassis mounted and one slot wide. It is the module chosen when the ControlNet trunk runs through an enclosure that is not heated or that carries corrosive atmosphere.

Table 25 publishes 131 connections supported in total, 1300 mA at 5.1 V DC (1.3 A), redundant configuration, isolation 30 V continuous basic insulation between ControlNet A/B and the backplane, A to B, USB to ControlNet A/B and USB to backplane, type tested at 500 V AC for 60 s. The port pair connects to 1786-RG6 quad-shield RG6 coaxial cable, wiring category 1 on the ControlNet ports and 3 on the USB port, temperature code T4, with a 12 Mbps USB port for local programming.

1756-CN2ControlNet bridge, 1 BNC port, 128 Logix connectionsIN STOCK
1756-CN2RRedundant ControlNet bridge, 2 BNC ports, 128 Logix connectionsIN STOCK
1756-CN2RXTRedundant ControlNet bridge, -25...70 C, conformal coatedIN STOCK
1756-CNBControlNet bridge, 1 BNC port, 40...48 Logix connectionsIN STOCK
1756-CNBRRedundant ControlNet bridge, 2 BNC ports, 40...48 connectionsIN STOCK

 Application
 ControlNet
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-CN2RXT
 Communication
 ControlNet
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 2 ControlNet BNC (5 Mbps, redundant)
 Mounting
 Chassis
 Number Of Channels
 2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix system user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-CN2RXT product photograph product photograph 1756-CN2RXT module product photograph 1756-CN2RXT module, second view product photograph

Where the module sits in a typical system

The module belongs to panels that see cold starts and contamination: an outdoor skid, an unheated MCC room, a plant with sulphur or salt in the air. The -25…+70 °C range is what the XT rating adds over the standard CN2R, and the conformal coating is what carries the corrosive-atmosphere qualification.

The rating is a property of the assembly. 1756-TD003 states the XT chassis and XT supply are part of the specification, so pairing this module with a standard chassis leaves the system at the standard temperature.

Commissioning in five steps

  1. Set the node address on the module before it joins the segment — the ControlNet address is the module's identity on the wire, and two modules at the same address will not both come online.
  2. Use 1786-RG6 quad-shield coax with the published connectors and terminators; control the trunk length and the number of taps against the ControlNet planning rules, not by eye.
  3. Insert the module in any 1756 chassis slot; the published chassis are 1756-A4, A7, A10, A13 and A17 (1756-TD003 Table 22).
  4. Add the module to the I/O configuration in Studio 5000 and schedule the network — an unscheduled ControlNet segment carries no I/O regardless of the wiring.
  5. Read the indicators at power-up: a module that shows no network activity on a scheduled, terminated segment is an addressing or cabling fault before it is a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 OK Flashing green Power-up self-test in progress; wait for the solid state.
 OK Off No chassis power at the slot, or the module failed its self-test.
 ControlNet A / B Green solid The port is on the network and exchanging scheduled data.
 ControlNet A / B Flashing green Connected but not scheduled, or not the keeper for that trunk.
 ControlNet A / B Flashing red Duplicate node address or a configuration mismatch on that port.
 ControlNet A / B Off No activity on that port: trunk unterminated, cable open, or the port unused.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix System User Manual) and 1756-IN050.

Replacing a ControlNet segment

ControlNet is a legacy network; Rockwell publishes the migration as CNET-RM001. There is no published ControlNet-XT successor for this catalogue number.

In an existing XT panel the spare is another CN2RXT, because the standard CN2R would drop the assembly to 0…60 °C. Moving the segment to EtherNet/IP means an XT EtherNet/IP module such as the EN2TRXT for the same environment, with that module's connection figures replacing the 131 supported here.

Which ControlLogix ControlNet module to specify

  • 1756-CN2 — one BNC port, 128 Logix connections, 1.1 A at 5.1 V DC, 3 mA at 24 V DC. The standard bridge for a single ControlNet segment.
  • 1756-CN2R — two BNC ports for a redundant trunk, same 128 Logix connections, 1.3 A at 5.1 V DC. Three connections are reserved for redundant control.
  • 1756-CN2RXT — the redundant module in the XT range, -25…+70 °C, 1.3 A at 5.1 V DC, wired to 1786-RG6 quad-shield coax.
  • 1756-CNB — one BNC port, 40…48 Logix connections, 970 mA at 5.1 V DC. The smaller bridge for a short segment.
  • 1756-CNBR — two BNC ports, 40…48 Logix connections, 970 mA at 5.1 V DC. Redundancy at the lower connection count.
  • 1756-EN2T / EN2TR — not ControlNet parts: the EtherNet/IP equivalent when the network itself is being replaced.

FAQ — ControlLogix-XT 1756-CN2RXT / 1756CN2RXT ControlNet Module

What makes the 1756-CN2RXT different from the 1756-CN2R?

The environment. Both are redundant two-port ControlNet modules at 5 Mbps with 1300 mA at 5.1 V DC; the XT version is conformal coated and rated -25…+70 °C for use in unheated or corrosive enclosures (1756-TD003 Tables 22 and 25).

What temperature range does it publish?

-25…+70 °C (-13…+158 °F) operating, which is the extended range listed for this module in the ControlNet selection table — the standard CN2 and CN2R publish 0…60 °C (Table 22). The range belongs to the whole XT assembly, chassis and supply included.

How much current does the XT module draw?

1300 mA at 5.1 V DC (1.3 A) per Table 25 — the same figure as the standard redundant CN2R, so a substitution inside an existing XT panel does not change the supply calculation.

How many connections can it carry?

131 connections supported in total in the redundant configuration (Table 25), the same total as the CN2R, with 5 Mbps on the ControlNet trunk and up to 99 nodes on the network.

What cable and wiring category does it use?

1786-RG6 quad-shield RG6 coaxial cable, wiring category 1 on the ControlNet ports and 3 on the USB port (Table 25). The USB port runs at 12 Mbps and is for temporary local programming.

What isolation and certification does it carry?

30 V continuous basic insulation between ControlNet A/B and the backplane, A to B, USB to ControlNet A/B and USB to backplane, type tested at 500 V AC for 60 s (Table 25); T4 temperature code. Certifications per Table 6: c-UL-us UL E65584 and Class I Division 2 UL E194810, CSA LR54689C and LR69960C, CE to 2014/30/EU, RCM, ATEX II 3 G Ex ec IIC T4 Gc, UKEX UL22UKEX2604X, UKCA, IECEx UL 22.0063X, FM Class I Division 2, KC, ODVA and CCC 2020122309111998.

Which chassis must it be paired with?

The XT chassis carry the extended range; the module does not create it alone. Fit it in a standard 1756-A7 or A10 and the assembly is limited to that chassis rating, so the XT chassis and XT supply are specified together with the module.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-UM001 (ControlLogix System User Manual) and CNET-RM001 (ControlNet to EtherNet/IP Migration Reference Manual) and the manufacturer's product page for 1756-CN2RXT. Values re-checked 15 November 2026.