Allen Bradley PLC 1756-EN3TR / 1756EN3TR

China Allen Bradley PLC 1756-EN3TR / 1756EN3TR supplier
Allen Bradley PLC 1756-EN3TR / 1756EN3TR supplier Allen Bradley PLC 1756-EN3TR / 1756EN3TR supplier Allen Bradley PLC 1756-EN3TR / 1756EN3TR supplier Allen Bradley PLC 1756-EN3TR / 1756EN3TR supplier Allen Bradley PLC 1756-EN3TR / 1756EN3TR supplier Allen Bradley PLC 1756-EN3TR / 1756EN3TR supplier Allen Bradley PLC 1756-EN3TR / 1756EN3TR supplier

Large Image :  Allen Bradley PLC 1756-EN3TR / 1756EN3TR

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-EN3TR / 1756EN3TR

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $2135.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-EN3TR technical data PDF download ControlLogix 1756-EN3TR / 1756EN3TR EtherNet/IP Motion Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-EN3TR (also written 1756EN3TR) is the motion-capable EtherNet/IP communication module for the ControlLogix 1756 platform: two RJ45 ports rated Category 5E at 10/100 Mbps, chassis mounted and one slot wide. It carries the same port pair and the same connection counts as the 1756-EN2TR; the published difference is the axis count — up to 128 integrated-motion axes on the EtherNet/IP network against eight on the EN2TR (1756-TD003 Table 3).

Connections are 128 TCP/IP, 256 CIP and 128 + 128 CIP unconnected messages (Table 1). Current draw is 1.2 A at 5.1 V DC and 3 mA at 24 V DC, dissipating 6.12 W and 20.9 BTU/hr; isolation is 30 V continuous basic insulation, type tested at 860 V AC for 60 s (Table 4). The firmware column starts at 3.6 or later, which means Studio 5000 / RSLogix 5000 18.02.00, RSLinx 2.56 and a packet rate of 25,000 packets/s (Table 3).

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 EtherNet/IP
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-EN3TR
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 2 Copper RJ45 (10/100 Mbps, Category 5E)
 Mounting
 Chassis
 Number Of Channels
 2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-EN3TR sealed carton product photograph 1756-EN3TR cartons product photograph 1756-EN3TR carton labels product photograph

Where the module sits in a typical system

In a motion cell the module is the slot the servo drives hang from: the controller sends position and velocity over EtherNet/IP through this one module, and the port pair can be wired as a DLR ring so a single cable break does not stop the axis group.

The 128-axis ceiling is what makes this a different specification rather than an upgrade: a machine running more than eight axes on the network cannot be served by the EN2TR, and a cell that also carries HMI, SCADA and programming traffic shares the same 128 TCP connections between them.

Commissioning in five steps

  1. Set the IP address before the module is inserted — BOOTP/DHCP server, or a static address written in Studio 5000 and sent on download. Duplicate-IP detection is active at all revisions (1756-TD003 Table 2).
  2. Insert the module in any 1756 chassis slot; standard supplies 1756-PA72/PA75/PB72/PB75/PC75/PH75, redundant supplies 1756-PA75R/PB75R/PSCA2.
  3. Cable the published port type — copper twisted pair to the category listed for the module, fibre to multimode LC where the module is a fibre unit — and stay inside the channel limit.
  4. Add the module to the I/O configuration in Studio 5000. The generic Ethernet module entry is enough for messaging; an EDS or Add-on Profile is needed for ring supervision or integrated motion.
  5. Power up and read the indicators. A dark network indicator with a dark link pair is an addressing or cabling fault, not a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 OK  Flashing green  Power-up self-test in progress; wait for the solid state.
 OK  Off  No chassis power at the slot, or the module failed its self-test.
 NET  Green solid  CIP connections established to at least one device.
 NET  Flashing green  IP address present, no CIP connection — check the connection entry and the axis group in Studio 5000.
 NET  Off  No IP address; the module is not on the network yet.
 LINK 1 / LINK 2  Green solid  Port linked at 10 or 100 Mbps.
 LINK 1 / LINK 2  Off  No link on that port: cable, connector or partner port.

Indicator behaviour per Rockwell publication 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and 1756-IN050.

Replacing a 1756-ENBT

The 1756-ENBT was discontinued by Rockwell on 1 November 2021 and the published replacement is the 1756-EN2T. Where the ENBT slot drives a motion application above eight axes, the substitute has to be the EN3TR — the EN2T and EN2TR publish an eight-axis limit (Table 3), this module publishes 128.

The draw rises from 700 mA to 1.2 A at 5.1 V DC, so 500 mA is re-added to the slot budget. The program side is the real work: an axis group is re-created against the new module, and the motion connections count against the same 128 CIP connections as everything else in the chassis.

Which ControlLogix EtherNet/IP module to specify

  • 1756-EN2T — single copper port, 128 TCP / 256 CIP, 1 A at 5.1 V. Star topology, lowest slot draw.
  • 1756-EN2TR — two copper ports, same connection counts, 1.2 A. DLR ring or linear chain.
  • 1756-EN2TRXT — the dual-port module in the XT range, -25…+70 °C, conformal coated.
  • 1756-EN2TP — two ports for parallel redundancy (PRP), no ring.
  • 1756-EN3TR — two ports with integrated motion up to 128 axes.
  • 1756-EN4TR — 512 TCP / 1000 I/O connections, 1 Gbps capable, CIP Security, redundant adapters.
  • 1756-EN2F — fibre port, 100 Mbps fixed, for links beyond copper distance or through high-EMI areas.

FAQ — ControlLogix 1756-EN3TR / 1756EN3TR EtherNet/IP Motion Module

What separates the 1756-EN3TR from the 1756-EN2TR?

The axis count, not the network. Both have two RJ45 Category 5E ports, 128 TCP/IP connections, 256 CIP connections and 1.2 A draw at 5.1 V DC (Tables 1 and 4). The EN3TR supports up to 128 integrated-motion axes on EtherNet/IP; the EN2T and EN2TR publish eight (Table 3).

Does the module require a ring topology?

No. The second port can run a device-level ring or a linear chain, or be left unused in a star. The ring is an option for cable-fault tolerance, not a condition for motion.

Which software version does it need?

Firmware 3.6 or later with Studio 5000 / RSLogix 5000 18.02.00 or later and RSLinx 2.56 or later, giving 25,000 packets/s at the published maximum (Table 3). There is no earlier firmware column for this module; an older project has to be brought up to that version first.

How many axes and connections can one module carry at the same time?

The published limits are 128 axes on the motion side and 128 TCP/IP connections on the messaging side, with 256 CIP connections shared across both. In practice the axis count, the I/O connections of the same cell and any HMI or programming sessions all draw from that same CIP budget.

What are the environmental limits and certifications?

Operating 0…60 °C in a Series C chassis, 0…50 °C in a Series B chassis; storage -40…85 °C; 5…95% RH non-condensing; 2 g vibration at 10…500 Hz; 30 g shock; CISPR 11 Class A; ESD 6 kV contact and 8 kV air; EFT ±3 kV at 5 kHz and surge ±2 kV line-earth on the Ethernet ports; T4; open-style (Tables 4 and 5). Certifications: c-UL-us UL E65584 and Class I Division 2 UL E194810, CE to 2014/30/EU, RCM, ATEX 2014/34/EU II 3 G Ex ec IIC T4 Gc under UL 22 ATEX 2818X, UKEX UL22UKEX2604X, UKCA, FM Class I Division 2, IECEx UL 22.0063X, KC, ODVA conformance and CCC 2020122309111998 (Table 6).

What is the backplane load of the motion module?

1.2 A at 5.1 V DC, 3 mA at 24 V DC, 6.12 W and 20.9 BTU/hr, with 30 V continuous basic isolation type tested at 860 V AC for 60 s (1756-TD003 Table 4). The figure is identical to the EN2TR, so swapping one for the other does not change the power budget.

Which chassis and power supplies accept it?

Any slot of 1756-A4, A7, A10, A13 or A17, with the 1756-PA72, PA75, PB72, PB75, PC75 or PH75 supply or the redundant PA75R, PB75R and PSCA2 pair (Table 4). One slot wide, open-style, T4 temperature code.

How does its firmware requirement differ from the EN2TR?

The EN2TR publishes two columns — firmware 2.x at 17.01.02 with RSLinx 2.55 and 10,000 packets/s, firmware 5.x at 18.02.00 with 2.56 and 25,000 packets/s. The EN3TR starts at 3.6 or later, 18.02.00 and 2.56, at 25,000 packets/s, and publishes 128 axes where the EN2TR publishes eight (Table 3).


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-EN3TR. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)