logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT

China Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT supplier
Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT supplier Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT supplier Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT supplier Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT supplier Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT supplier Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT supplier Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT supplier

Large Image :  Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-EN2TXT / 1756EN2TXT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $2205.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK;
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description


1756-EN2TXT technical data PDF download ControlLogix 1756-EN2TXT / 1756EN2TXT EtherNet/IP Module (XT)

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-EN2TXT (also written 1756EN2TXT) is the extended-environment version of the ControlLogix EtherNet/IP bridge: two RJ45 Category 5 ports at 10/100 Mbps, 256 Logix connections, 128 TCP connections, one slot wide. It runs the same EtherNet/IP stack as the 1756-EN2T; what changes is the conformal coating, the -25…+70 °C range and the G3/CX corrosion rating, and those are carried by the XT chassis it is installed in (1756-TD003 Table 7).

Current draw is 1 A at 5.1 V DC, dissipating 5.1 W and 17.4 BTU/hr — 200 mA less than the two-port standard model, which matters when an XT panel is sized around a small 1756-PAXT supply. Isolation is 30 V continuous basic insulation, compliant and tested to IEC/UL 61010-1; Table 7 publishes no type-test voltage for the XT family. The front USB port runs at 12 Mbps, the temperature code is T4 and the module is open-style.

1756-EN2FCLX HI CAP EIP MOD - FBRIN STOCK
1756-EN2TControlLogix Hi Capacity ENET/IPIN STOCK
1756-EN2TR2-PORT CLX HI-CAP ENET/IP MODULE - TPIN STOCK
1756-EN2TRXTCLX ENET/IP Module - 2TP -X EnvtIN STOCK
1756-EN2TSCEtherNet/IP Hi Prof Sngl Port VPN BridgeIN STOCK
1756-EN2TXTCLX ENET/IP MODULE - TP, X-ENVTIN STOCK
1756-EN3TRControlLogix Ethernet Motion ModuleIN STOCK
1756-ENBTControlLogix Communication ModuleIN STOCK
1756-EWEBControlLogix Web Server ModuleIN STOCK
1756-EXTControlLogix Backplane ExtenderIN STOCK
1756-HIST1GHistorian ME 1 Gig in ControlLogix RackIN STOCK
1756-HIST2GHistorian ME 2 Gig in ControlLogix RackIN STOCK
1756-HSCControlLogix High-Speed Counter ModuleIN STOCK
1756-HYD02ControlLogix Analog Combination ModuleIN STOCK

 Application
 EtherNet/IP
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-EN2TXT
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 2 Copper RJ45 (10/100 Mbps, Category 5)
 Mounting
 Chassis
 Number Of Channels
 2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-EN2TXT sealed carton product photograph 1756-EN2TXT cartons product photograph 1756-EN2TXT carton labels product photograph

Where the module sits in a typical system

The module is for panels that are not heated: an outdoor skid, a wash-down area, a plant where hydrogen sulphide or salt mist is present. The -25 °C start and the coating are the reason to pay for the XT part, and they only exist as long as the whole assembly is XT — module, chassis and supply.

On the network it does the ordinary bridge job: I/O, drives, HMI and programming traffic share the 128 TCP and 256 Logix connections, and the two ports can run a device-level ring or two separate segments.

Commissioning in five steps

  1. Set the IP address before the module is inserted — BOOTP/DHCP server, or a static address written in Studio 5000 and sent on download. Duplicate-IP detection is active at all revisions (1756-TD003 Table 2).
  2. Insert the module in any 1756 chassis slot; standard supplies 1756-PA72/PA75/PB72/PB75/PC75/PH75, redundant supplies 1756-PA75R/PB75R/PSCA2.
  3. Cable the published port type — copper twisted pair to the category listed for the module, fibre to multimode LC where the module is a fibre unit — and stay inside the channel limit.
  4. Add the module to the I/O configuration in Studio 5000. The generic Ethernet module entry is enough for messaging; an EDS or Add-on Profile is needed for ring supervision or integrated motion.
  5. Power up and read the indicators. A dark network indicator with a dark link pair is an addressing or cabling fault, not a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 OK Flashing green Power-up self-test in progress; wait for the solid state.
 OK Off No chassis power at the slot, or the module failed its self-test.
 NET Green solid CIP connections established to at least one device.
 NET Flashing green IP address present, no CIP connection — check the connection entry in Studio 5000.
 NET Off No IP address; the module is not on the network yet.
 LINK 1 / LINK 2 Green solid Port linked at 10 or 100 Mbps.
 LINK 1 / LINK 2 Off No link on that port: cable, connector or partner port.

Indicator behaviour per Rockwell publication 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and 1756-IN050.

Replacing a 1756-ENBT

The 1756-ENBT reached End of Life on 1 November 2021 and the published replacement is the 1756-EN2T. In an XT panel the equivalent slot is this module: same connection capacity as the ENBT path in Table 7 at 128 TCP and 256 Logix, and 1 A draw against the ENBT's 700 mA.

The substitution does not end at the module. The XT chassis 1756-A7XT/C, A10XT/C, A7ZXT or A10ZXT and the PAXT, PBXT or PA75XT supply are part of the same assembly; fitting an XT module into a standard chassis gives back the standard 0…60 °C rating.

Which ControlLogix EtherNet/IP module to specify

  • 1756-EN2T — single copper port, 128 TCP / 256 CIP, 1 A at 5.1 V. Star topology, lowest slot draw.
  • 1756-EN2TR — two copper ports, same connection counts, 1.2 A. DLR ring or linear chain.
  • 1756-EN2TRXT — the dual-port module in the XT range, -25…+70 °C, conformal coated.
  • 1756-EN2TP — two ports for parallel redundancy (PRP), no ring.
  • 1756-EN3TR — two ports with integrated motion up to 128 axes.
  • 1756-EN4TR — 512 TCP / 1000 I/O connections, 1 Gbps capable, CIP Security, redundant adapters.
  • 1756-EN2F — fibre port, 100 Mbps fixed, for links beyond copper distance or through high-EMI areas.

FAQ — ControlLogix 1756-EN2TXT / 1756EN2TXT EtherNet/IP Module (XT)

What does the XT suffix add over the standard 1756-EN2T?

Conformal coating, a -25…+70 °C operating range and a G3/CX corrosion rating, all carried by the XT chassis and supply. The network side is unchanged: two RJ45 Category 5 ports at 10/100 Mbps, 128 TCP and 256 Logix connections (Table 7).

What is its current draw and thermal load?

1 A at 5.1 V DC, 5.1 W and 17.4 BTU/hr, one slot wide (Table 7). That is 200 mA below the standard two-port EN2TR, which buys headroom on a small XT power supply.

Which chassis and power supplies is it approved with?

1756-A7XT/C, A10XT/C, A7ZXT or A10ZXT with the PAXT, PBXT or PA75XT supply, or the redundant PAXTR and PBXTR pairing (Tables 7 and 8). The XT chassis is what makes the extended rating real.

Do the XT ratings still apply if I fit it in a standard chassis?

No. The -25…+70 °C range, the coating and the G3/CX rating are properties of the complete XT assembly. In a 1756-A7 or A10 chassis the module is limited by that chassis rating.

What environmental limits are published?

Operating -25…+70 °C; storage -40…85 °C; conformal coated; corrosion resistance G3/CX; 2 g vibration; 30 g shock; CISPR 11 Class A; ESD 6 kV contact and 8 kV air; radiated RF immunity tested to 6000 MHz; EFT ±3 kV and surge ±2 kV line-earth on the Ethernet ports (Tables 7 and 9).

Which certifications does the XT module carry?

c-UL-us, CE, RCM, ATEX to EN 60079-7, UKEX, UKCA, IECEx UL 22.0063X, KC, ODVA conformance, Morocco and CCC (Table 9). FM approval is not listed for the XT family.

How many connections can it carry?

128 TCP connections and 256 Logix connections (Table 7), the same figures as the standard EN2T and EN2TR. I/O, drives, HMI sessions and programming traffic all draw from that same budget.

Is this the module that replaces the 1756-ENBT in cold panels?

Yes for XT installations. The ENBT reached End of Life on 1 November 2021 with the 1756-EN2T as its published replacement; in an unheated or corrosive enclosure the equivalent slot is the EN2TXT, at 1 A draw instead of 700 mA.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-EN2TXT. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956