logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-L63S / 1756L63S

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-L63S / 1756L63S

China Allen Bradley PLC 1756-L63S / 1756L63S supplier
Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier Allen Bradley PLC 1756-L63S / 1756L63S supplier

Large Image :  Allen Bradley PLC 1756-L63S / 1756L63S

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-L63S / 1756L63S

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $7158.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-L63S technical data PDF download GuardLogix 1756-L63S / 1756L63S 8 MB Safety Controller

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-L63S (also written 1756L63S) is the largest GuardLogix 5560 controller: 8 MB of user memory and 3.75 MB of safety memory, used as a pair with the 1756-LSP safety partner in the slot immediately to its right. Together the pair reaches SIL CL 3 / PL e / Category 4, with the safety and standard logic in one project and one tag database (1756-TD001I Tables 14 and 18).

Current draw is 1200 mA at 5.1 V DC and 14 mA at 24 V DC per module, 3.5 W and 11.9 BTU/hr; isolation is 30 V continuous basic insulation from the RS-232 port to the system, type tested at 720 V DC for 60 s. Digital I/O is limited to 128,000 points and analogue to 4,000. Controller redundancy is not supported on any GuardLogix controller.

1756-L61SGuardLogix 5560 safety controller, 2 MB user / 1 MB safetyIN STOCK
1756-L62SGuardLogix 5560 safety controller, 4 MB user / 1 MB safetyIN STOCK
1756-L63SGuardLogix 5560 safety controller, 8 MB user / 3.75 MB safetyIN STOCK
1756-L61ControlLogix 5560 standard controller, 2 MBIN STOCK
1756-L63ControlLogix 5560 standard controller, 8 MBIN STOCK
1756-L65ControlLogix 5560 standard controller, 32 MBIN STOCK

 Application
 Safety Control (SIL 3 / PL e)
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-L63S
 Communication
 Backplane (EtherNet/IP, ControlNet, DeviceNet)
 Display
 Indicators (OK, RUN, I/O, FORCE, BATTERY, RS-232)
 Enclosure
 None (open-style)
 Interface
 1 RS-232 serial port
 Mounting
 Chassis
 Number Of Channels
 1
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Safety Controller
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-RM093 (GuardLogix safety reference manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-L63S GuardLogix controller product photograph 1756-L63S controller product photograph 1756-L63S controller label product photograph

Where the module sits in a typical system

3.75 MB of safety memory is the reason this part exists: a multi-station line where the safety program covers several zones of guarding, muting and safe-speed logic and no longer fits the 1 MB the smaller pairs offer, while the 8 MB standard side carries the cell's own sequencing and recipe data.

The pair is the safety unit — two slots, primary plus partner — and the networks are EtherNet/IP, ControlNet and DeviceNet for both standard and safety traffic. Because redundancy is not supported, availability has to come from the machine design rather than from a second controller.

Commissioning in five steps

  1. Install the primary controller and the 1756-LSP safety partner as a pair: the partner goes in the slot immediately to the right of the primary, and the pair occupies two slots. A single controller in a chassis does not run the safety task.
  2. The safety partner is configured automatically — no IP address, no project of its own. The safety logic is in the primary controller's project, in a safety task that is set to its integrity level.
  3. Budget the chassis against 1200 mA at 5.1 V DC plus 14 mA at 24 V DC for each of the two modules, and check that the supply is one from the published list: 1756-PA72, PA75, PB72 or PB75.
  4. Read the safety status before validating: the project reports a safety-task signature and a partner status, and a missing or mismatched partner is a configuration fault, not a field-device fault.
  5. Lock and protect the safety memory only after the safety task has been functionally tested; once locked, the safety logic cannot be edited and the SIL 3 claim applies.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 OK Red Major fault or self-test failure; check the safety task status before any restart.
 RUN Green solid Program running, standard and safety tasks executing.
 RUN Red Major fault latched; the program is stopped.
 I/O Green solid All configured I/O modules are communicating.
 I/O Flashing green One or more configured modules are not responding.
 FORCE Amber Forces enabled in the standard task — a live wiring check is not valid while this is lit.
 BATTERY Red Battery low or missing; the project in RAM is not protected across a power cycle.
 Partner status Per project The safety partner is reported in the project: a missing or mismatched partner stops the safety task from validating.
 RS-232 Green flashing Serial activity on the programming port.

Indicator behaviour per Rockwell publication 1756-UM020 (GuardLogix Controllers User Manual) and 1756-IN050.

Replacing a 1756-ENBT

The 5560 family is discontinued; the successor pairs are 1756-L73S + 1756-L7SP in the GuardLogix 5570 range, or the 5580 safety controllers. The pair, not the primary alone, is what gets replaced, because the partner part number changes with the family.

With 3.75 MB of safety memory in use, the migration is a genuine program re-work: safety routine organisation is re-checked against the new controller's memory, the safety signature is regenerated, and the validated functional test is repeated.

Which GuardLogix safety controller to specify

  • 1756-L61S + 1756-LSP — 2 MB user memory, 1 MB safety memory. Smallest GuardLogix 5560 pair.
  • 1756-L62S + 1756-LSP — 4 MB user memory, 1 MB safety memory.
  • 1756-L63S + 1756-LSP — 8 MB user memory, 3.75 MB safety memory. The largest 5560 safety pair; the one most SIL 3 cells were built around.
  • 1756-LSP — the safety partner; it is not a spare of the primary controller and cannot be used on its own.
  • 1756-L7xS + 1756-L7SP — the GuardLogix 5570 pairs, 2 to 8 MB user and 1.5 to 4 MB safety memory.

FAQ — GuardLogix 1756-L63S / 1756L63S 8 MB Safety Controller

How much safety memory does the 1756-L63S have?

3.75 MB of safety memory against 1 MB on the 1756-L61S and L62S, with 8 MB of user memory for the standard side and 478 KB of I/O memory (1756-TD001I Table 18). This is the largest safety memory published for the GuardLogix 5560 range.

What rating does the pair achieve?

SIL CL 3 per IEC 61508/EN 62061 and Category 4 / PL e per EN ISO 13849-1 when used as described in 1756-RM093; TÜV certifies the functional safety and UL certifies SIL CL 3 under file E256621 (Table 20).

Does the safety partner have its own memory?

It carries the same safety memory as its corresponding primary controller, and the table lists it as a dash for user memory — the 1756-LSP is a partner, not a controller in its own right, and cannot be used alone.

How is the pair installed in a chassis?

Primary controller plus 1756-LSP in the slot immediately to the right, two slots total, in any slot of a 1756-A4, A7, A10, A13 or A17 chassis. Moving the partner away from that position breaks the configuration.

What is the power budget?

1200 mA at 5.1 V DC and 14 mA at 24 V DC per module, 3.5 W and 11.9 BTU/hr per module (Table 18) — counted twice for a pair. Published supplies for the L6xS pair are 1756-PA72, PA75, PB72 and PB75.

Can the safety program be edited after validation?

Not while the safety memory is locked and protected. Locking follows the functional test; after that the safety logic cannot be modified and the SIL 3 claim holds. Before locking, online editing and forcing are allowed in the standard task.

What are the environmental limits and certifications?

Operating 0…60 °C, storage -40…85 °C, 5…95% RH non-condensing, 2 g vibration at 10…500 Hz, 30 g and 50 g shock, CISPR 11 Class A, ESD 6 kV contact and 8 kV air, radiated RF 10 V/m 80…2000 MHz and 3 V/m 2000…2700 MHz, EFT ±4 kV at 5 kHz and surge ±2 kV line-earth (Table 19). Certifications: c-UL-us UL E65584/E194810, CSA LR54689C/LR69960C, CE 2004/108/EC and 2006/42/EC, C-Tick/RCM, FM Class I Division 2 and KC (Table 20).

What is the difference from the standard 1756-L63?

The safety task, the safety memory and the second slot. The standard 1756-L63 is a single-slot controller with no safety rating, 8 MB of user memory and 0.32 kg; the L63S pair adds 3.75 MB of safety memory plus the partner module, and the safety certifications that follow from it.


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-RM093 (GuardLogix Controller Systems Safety Reference Manual) and the manufacturer's product page for 1756-L63S. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)