Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OV32E / 1756OV32E

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $368.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description


1756-OV32E technical data PDF download 1756-OV32E ControlLogix 32 Point Sinking DC Output | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OV32E (also written 1756OV32E) is the 32-point sinking DC output module: 10...30 V DC, 350 mA per point at 60 °C and 500 mA at 50 °C, pilot duty (DC-13/SS), group current 5 A at 60 °C and 8 A at 50 °C, backplane 390 mA at 5.1 V DC and 2 mA at 24 V DC (1756-IN062).

The published limit here is per group, not per module: 5 A at 60 °C and 8 A at 50 °C. With 32 points split into groups, each group's total is the number that binds, and the per-point figure of 350 to 500 mA is only usable while the group sum holds.

390 mA at 5.1 V DC is the highest backplane draw in the family, higher even than the 350 mA of the OB16I. Thirty-two sinking outputs cost more on the chassis rail than any 16-point card.

It is the dense sinking card: 32 switched returns in one slot, at DC-13/SS pilot duty, for panels whose field devices are fed +24 V and expect their return to be made by the controller.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OV32E
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 32
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OV32E module product photograph 1756-OV32E label product photograph 1756-OV32E terminal side product photograph

Where the module sits in a typical system

The OV32E suits large 24 V DC output lists that expect a switched return: banks of valve islands, drive input blocks with common-cathode wiring, and third-party I/O that sinks its inputs.

Design to the group ceiling. Thirty-two points at 350 mA would be 11 A in total, which no group arrangement delivers — the published 5 A and 8 A figures decide how many points can run together.

Where 1 A per point is needed on sixteen channels, the OV16E offers more current per point at half the density and a lighter 5.1 V draw.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 350 to 500 mA per point The per-point figure falls with temperature, and only inside the group sum.
 Check 3 390 mA backplane The highest 5.1 V draw in the DC output family.
 Check 4 Sinking polarity Return-switching: verify the field supply shares a reference with the module's return.
 Check 5 32 points in one slot Density is the argument for this card; wiring two groups of sixteen keeps the returns simple.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For 16 sinking points at 1 A, 1756-OV16E publishes 1 A pilot duty with an 8 A output maximum.

For 32 sourcing points at 500 mA, 1756-OB32 has the same density with the opposite polarity.

For 16 sourcing points at 1 A with 2 A inrush, 1756-OB16E is the standard card.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OV32E ControlLogix 32 Point Sinking DC Output | Rockwell

What is the 1756-OV32E?

A 32-point sinking DC output module, 10...30 V DC, 350 mA per point at 60 °C and 500 mA at 50 °C.

What is the current limit?

5 A per group at 60 °C and 8 A per group at 50 °C — published per group, not per module.

What is the backplane current?

390 mA at 5.1 V DC and 2 mA at 24 V DC, the highest in the DC output family.

What does sinking mean?

It switches the return path; the field device is fed +24 V and the module makes its return.

How is it isolated?

250 V basic outputs-to-backplane and 250 V basic between output groups, with none between individual outputs.

What is the pilot duty rating?

DC-13/SS.

What is its temperature code?

T4 under the North American classification.

Which document publishes these figures?

1756-IN062, the ControlLogix DC digital I/O installation instructions.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OV32E. Values re-checked 15 November 2026.