logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OB16E / 1756OB16E

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OB16E / 1756OB16E

China Allen Bradley PLC 1756-OB16E / 1756OB16E supplier
Allen Bradley PLC 1756-OB16E / 1756OB16E supplier Allen Bradley PLC 1756-OB16E / 1756OB16E supplier Allen Bradley PLC 1756-OB16E / 1756OB16E supplier Allen Bradley PLC 1756-OB16E / 1756OB16E supplier Allen Bradley PLC 1756-OB16E / 1756OB16E supplier

Large Image :  Allen Bradley PLC 1756-OB16E / 1756OB16E

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OB16E / 1756OB16E

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $299.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-OB16E technical data PDF download 1756-OB16E ControlLogix 16 Point Electronically Fused DC Output | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OB16E (also written 1756OB16E) is the 16-point DC output module: 10...31.2 V DC, 1 A per point with 2 A inrush, backplane 250 mA at 5.1 V DC and 2 mA at 24 V DC, isolation 250 V continuous basic outputs-to-backplane and 125 V basic output-to-output, maximum module current 8 A at 60 °C (1756-IN062).

One amp per point with a 2 A inrush ceiling is the honest shape of this module. It drives lamps, small solenoids and relay coils comfortably; a contactor whose inrush exceeds 2 A needs a different output, and the OB16I at 2 A pilot duty is the next step up.

The isolation is split: 250 V to the backplane, but only 125 V between outputs. Two separate 24 V supplies can be used, and they must share a reference within that 125 V window — the OB16I publishes 250 V for the same arrangement.

Its temperature code is T4 rather than the T4A carried by most of the DC output table, and its backplane draw at 5.1 V DC is 250 mA, which is modest for sixteen channels and leaves room for input cards in the same chassis.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OB16E
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OB16E module product photograph 1756-OB16E label product photograph 1756-OB16E terminal side product photograph

Where the module sits in a typical system

The OB16E is the economical 16-point card for a panel full of indicator lamps, small solenoid valves and interposing relay coils, where 1 A per point is the real load and inrush stays under 2 A.

Its 250 mA backplane draw makes it the lighter choice when a chassis already carries several input modules and the 5.1 V budget is tight.

Where a point must drive a contactor at 2 A continuous, the OB16I or the OB16D is the module that publishes that rating; the OB16E does not.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 125 V output-to-output Half the barrier of the OB16I. Mixed supplies are allowed within that window, not beyond it.
 Check 3 8 A module maximum At 60 °C. Eight points at 1 A fills the module; the rest must be left off or moved to another card.
 Check 4 Inrush 2 A A contactor coil that pulls more than 2 A at pick-up will not be driven reliably by this output.
 Check 5 T4 temperature code 135 °C maximum surface temperature — a less restrictive code than the T4A modules.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For 2 A per point, 1756-OB16I publishes 24 V DC at 2 A pilot duty with 250 V output-to-output isolation.

For diagnostics with electronic fusing, 1756-OB16D publishes 2 A at 30 °C and 1 A at 60 °C across 19.2...30 V DC.

For 8 points with 250 V output-to-output isolation, 1756-OB8EI is the short version of this module.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OB16E ControlLogix 16 Point Electronically Fused DC Output | Rockwell

What is the 1756-OB16E?

A 16-point DC output module, 10...31.2 V DC, 1 A per point with 2 A inrush, backplane 250 mA at 5.1 V DC.

What is the maximum current per point?

1 A continuous, with a 2 A inrush allowance.

What is the module maximum?

8 A at 60 °C.

How is it isolated?

250 V continuous basic outputs-to-backplane and 125 V basic output-to-output.

Can I use two separate 24 V supplies?

Within the 125 V output-to-output barrier. For 250 V between outputs, use the OB16I.

Does it fuse each output electronically?

No — the electronically fused, load-diagnostic module is the OB16D. This is the standard 1 A card.

What is its temperature code?

T4, with 60 °C maximum surrounding air.

Which document quotes these figures?

1756-IN062, the ControlLogix DC digital I/O installation instructions.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB16E. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)