Product Details:
Payment & Shipping Terms:
|
The 1756-OA8D (also written 1756OA8D) is the diagnostic 8-point AC output module: 120 V AC 50/60 Hz, operating range 74…132 V AC at 47…63 Hz, diagnostic to point level, with electronic fusing per group of four points.
Current is 175 mA at 5.1 V and 250 mA at 24 V, total backplane power 6.89 W, dissipation 5.3 W at 60 °C (18.0 BTU/hr).
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
AC digital output module |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-OA8D |
Outputs |
8 diagnostic, electronic fusing (4 points/group) |
Voltage Category |
120 V AC 50/60 Hz |
Operating Voltage Range |
74…132 V AC, 47…63 Hz |
Output Delay |
9.3 ms @ 60 Hz; 11 ms @ 50 Hz |
Backplane Current |
175 mA @ 5.1 V; 250 mA @ 24 V |
Backplane Power |
6.89 W |
Power Dissipation |
5.3 W @ 60 °C |
Thermal Dissipation |
18.0 BTU/hr |
Current per Point |
1 A @ 30 °C, linear derating to 0.5 A @ 60 °C |
Current per Module |
8 A @ 30 °C, linear derating to 4 A @ 60 °C |
Surge Current per Point |
8 A for 43 ms @ 30 °C; 5 A for 43 ms @ 60 °C |
Off-state Leakage |
3 mA per point, max |
On-state Voltage Drop |
2.5 V peak @ 0.5 A; 3 V peak @ 1 A |
Load Current, Min |
10 mA per point |
Slot Width |
1 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The derating is the single most important figure on this module: 1 A per point at 30 °C, falling to 0.5 A at 60 °C, by linear derating. A panel designed at 1 A per point and installed in a hot enclosure runs at twice the permitted current, which is a common cause of unexplained fusing trips.
Per-module current follows the same rule: 8 A at 30 °C, 4 A at 60 °C. Divide by sixteen points across two modules before deciding how many solenoid valves or contactor coils can share an output card.
Protection is grouped, not per point. Electronic fusing covers four points per group, so a short on one output takes the group of four down until the fault clears. That is a deliberate trade: fewer fuses, wider blast radius, and it changes how the panel is sectioned.
Off-state leakage is up to 3 mA per point, and the on-state drop is 2.5 V peak at 0.5 A or 3 V peak at 1 A. Both are large enough to hold a small relay or a neon indicator in the wrong state, which is why the module is not recommended as a direct replacement for dry-contact outputs.
Minimum load is 10 mA per point, and surge capability is 8 A for 43 ms per point at 30 °C, derated to 5 A at 60 °C. Contactor coils and small brake solenoids fit; a 4 W pilot device does not draw enough to trip reliably.
Output delay is 9.3 ms at 60 Hz and 11 ms at 50 Hz, so a 50 Hz installation is also a slightly slower installation. Timing-critical interlocks belong on a DC module, not here.
Diagnostics are point level, but protection is per group of four points: a short anywhere in the group takes the group down, which is why the group boundary matters as much as the point rating.
| Indicator | State | Meaning and first action |
| Output heats up at 60 °C panel temperature | — | Current per point derates with temperature: 1 A at 30 °C becomes 0.5 A at 60 °C on the diagnostic module. |
| Output stays on with no command | — | Off-state leakage is up to 3 mA per point, enough to hold a small relay or a neon indicator energised. |
| Diagnostic does not report a short | — | The short-circuit trip needs a fault current above the published minimum; a soft short below it looks like a normal load. |
Backplane current, dissipation, derating and isolation per Rockwell publication 1756-TD002-EN-E and 1756-IN050.
Replace with the same catalogue number and the same group structure; a non-diagnostic OA8 has no point-level diagnostics.
Recalculate permitted current for the actual panel temperature before swapping in a higher-rated module.
Check the off-state leakage against the field device; a small relay may see 3 mA as a command.
What is the 1756-OA8D?
A diagnostic 8-point AC output module with electronic fusing per group of four points.
What voltage does it switch?
120 V AC 50/60 Hz, operating range 74…132 V AC at 47…63 Hz.
What current can each point carry?
1 A at 30 °C, derated linearly to 0.5 A at 60 °C.
What is the maximum per module?
8 A at 30 °C, derating to 4 A at 60 °C.
How much backplane current does it draw?
175 mA at 5.1 V and 250 mA at 24 V; 6.89 W total backplane power.
What does it dissipate?
5.3 W at 60 °C, 18.0 BTU/hr.
How much off-state leakage is there?
Up to 3 mA per point.
What is the output delay?
9.3 ms off-to-on at 60 Hz, 11 ms at 50 Hz.
What minimum load does it need?
10 mA per point.
Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (ControlLogix I/O Modules Specifications) - the table for 1756-OA8D, including backplane current, dissipation and per-point derating and the manufacturer's product page for 1756-OA8D. Values re-checked 16 November 2026.