Allen Bradley PLC 1756-OA8D / 1756OA8D

China Allen Bradley PLC 1756-OA8D / 1756OA8D supplier
Allen Bradley PLC 1756-OA8D / 1756OA8D supplier Allen Bradley PLC 1756-OA8D / 1756OA8D supplier Allen Bradley PLC 1756-OA8D / 1756OA8D supplier Allen Bradley PLC 1756-OA8D / 1756OA8D supplier Allen Bradley PLC 1756-OA8D / 1756OA8D supplier Allen Bradley PLC 1756-OA8D / 1756OA8D supplier Allen Bradley PLC 1756-OA8D / 1756OA8D supplier

Large Image :  Allen Bradley PLC 1756-OA8D / 1756OA8D

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OA8D / 1756OA8D

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $665.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OA8D technical data PDF download 1756-OA8D / 1756OA8D Diagnostic AC Output, 120 V

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OA8D (also written 1756OA8D) is the diagnostic 8-point AC output module: 120 V AC 50/60 Hz, operating range 74…132 V AC at 47…63 Hz, diagnostic to point level, with electronic fusing per group of four points.

Current is 175 mA at 5.1 V and 250 mA at 24 V, total backplane power 6.89 W, dissipation 5.3 W at 60 °C (18.0 BTU/hr).

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 AC digital output module
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OA8D
 Outputs
 8 diagnostic, electronic fusing (4 points/group)
 Voltage Category
 120 V AC 50/60 Hz
 Operating Voltage Range
 74…132 V AC, 47…63 Hz
 Output Delay
 9.3 ms @ 60 Hz; 11 ms @ 50 Hz
 Backplane Current
 175 mA @ 5.1 V; 250 mA @ 24 V
 Backplane Power
 6.89 W
 Power Dissipation
 5.3 W @ 60 °C
 Thermal Dissipation
 18.0 BTU/hr
 Current per Point
 1 A @ 30 °C, linear derating to 0.5 A @ 60 °C
 Current per Module
 8 A @ 30 °C, linear derating to 4 A @ 60 °C
 Surge Current per Point
 8 A for 43 ms @ 30 °C; 5 A for 43 ms @ 60 °C
 Off-state Leakage
 3 mA per point, max
 On-state Voltage Drop
 2.5 V peak @ 0.5 A; 3 V peak @ 1 A
 Load Current, Min
 10 mA per point
 Slot Width
 1

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OA8D AC output module product photograph 1756-OA8D, second view product photograph 1756-OA8D, third view product photograph

Where the module sits on an AC output circuit

The derating is the single most important figure on this module: 1 A per point at 30 °C, falling to 0.5 A at 60 °C, by linear derating. A panel designed at 1 A per point and installed in a hot enclosure runs at twice the permitted current, which is a common cause of unexplained fusing trips.

Per-module current follows the same rule: 8 A at 30 °C, 4 A at 60 °C. Divide by sixteen points across two modules before deciding how many solenoid valves or contactor coils can share an output card.

Protection is grouped, not per point. Electronic fusing covers four points per group, so a short on one output takes the group of four down until the fault clears. That is a deliberate trade: fewer fuses, wider blast radius, and it changes how the panel is sectioned.

Off-state leakage is up to 3 mA per point, and the on-state drop is 2.5 V peak at 0.5 A or 3 V peak at 1 A. Both are large enough to hold a small relay or a neon indicator in the wrong state, which is why the module is not recommended as a direct replacement for dry-contact outputs.

Minimum load is 10 mA per point, and surge capability is 8 A for 43 ms per point at 30 °C, derated to 5 A at 60 °C. Contactor coils and small brake solenoids fit; a 4 W pilot device does not draw enough to trip reliably.

Output delay is 9.3 ms at 60 Hz and 11 ms at 50 Hz, so a 50 Hz installation is also a slightly slower installation. Timing-critical interlocks belong on a DC module, not here.

Commissioning in five checks

  1. Choose D or E by current, not by feature name. Both fuse electronically; D gives diagnostics, E gives 2 A per point at 60 °C.
  2. Read the derating curve as part of the load calculation: 1 A at 30 °C is 0.5 A at 60 °C on OA8D.
  3. Treat a group of four points as one electrical unit. A short on one point takes the group out until the fault clears.
  4. Allow for 3 mA of off-state leakage per point when the load is a small relay or an indicator.
  5. Fit a 20-position RTB and keep field wiring off the 120 V AC module until the chassis is grounded and the supply is isolated.

Fusing trips and what they mean

Diagnostics are point level, but protection is per group of four points: a short anywhere in the group takes the group down, which is why the group boundary matters as much as the point rating.

 Indicator  State  Meaning and first action
 Output heats up at 60 °C panel temperature  —  Current per point derates with temperature: 1 A at 30 °C becomes 0.5 A at 60 °C on the diagnostic module.
 Output stays on with no command  —  Off-state leakage is up to 3 mA per point, enough to hold a small relay or a neon indicator energised.
 Diagnostic does not report a short  —  The short-circuit trip needs a fault current above the published minimum; a soft short below it looks like a normal load.

Backplane current, dissipation, derating and isolation per Rockwell publication 1756-TD002-EN-E and 1756-IN050.

Replacing a 1756-OA8D

Replace with the same catalogue number and the same group structure; a non-diagnostic OA8 has no point-level diagnostics.

Recalculate permitted current for the actual panel temperature before swapping in a higher-rated module.

Check the off-state leakage against the field device; a small relay may see 3 mA as a command.

Which module to specify

  • 1756-OA8D — diagnostic, electronic fusing per group of four, 1 A at 30 °C derating to 0.5 A at 60 °C.
  • 1756-OA8E — electronic fusing with 2 A per point at 60 °C and a 20 A surge rating.
  • 1756-OA8 — the non-diagnostic 8-point module in the same family.
  • 1756-OA16I — 16 individually isolated points where channel separation matters.
  • 1756-OW16I — relay output where the load is dry-contact rather than AC.

FAQ — 1756-OA8D / 1756OA8D Diagnostic AC Output, 120 V

What is the 1756-OA8D?

A diagnostic 8-point AC output module with electronic fusing per group of four points.

What voltage does it switch?

120 V AC 50/60 Hz, operating range 74…132 V AC at 47…63 Hz.

What current can each point carry?

1 A at 30 °C, derated linearly to 0.5 A at 60 °C.

What is the maximum per module?

8 A at 30 °C, derating to 4 A at 60 °C.

How much backplane current does it draw?

175 mA at 5.1 V and 250 mA at 24 V; 6.89 W total backplane power.

What does it dissipate?

5.3 W at 60 °C, 18.0 BTU/hr.

How much off-state leakage is there?

Up to 3 mA per point.

What is the output delay?

9.3 ms off-to-on at 60 Hz, 11 ms at 50 Hz.

What minimum load does it need?

10 mA per point.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (ControlLogix I/O Modules Specifications) - the table for 1756-OA8D, including backplane current, dissipation and per-point derating and the manufacturer's product page for 1756-OA8D. Values re-checked 16 November 2026.