logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OA8 / 1756OA8

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OA8 / 1756OA8

China Allen Bradley PLC 1756-OA8 / 1756OA8 supplier
Allen Bradley PLC 1756-OA8 / 1756OA8 supplier Allen Bradley PLC 1756-OA8 / 1756OA8 supplier Allen Bradley PLC 1756-OA8 / 1756OA8 supplier Allen Bradley PLC 1756-OA8 / 1756OA8 supplier Allen Bradley PLC 1756-OA8 / 1756OA8 supplier

Large Image :  Allen Bradley PLC 1756-OA8 / 1756OA8

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OA8 / 1756OA8

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $308.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-OA8 technical data PDF download 1756-OA8 ControlLogix 8 Point AC Output Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OA8 (also written 1756OA8) is the 8-point AC triac output module: 120/240 V AC at 50/60 Hz, 2 A pilot duty, backplane 200 mA at 5.1 V DC and 2 mA at 24 V DC, isolation 125 V continuous basic outputs-to-backplane with no isolation between individual outputs, and unfused at module level — the published fusing table lists the OA8D and OA8E as electronically fused per point, the OA16 as mechanically fused per group, and all other modules as not protected, which includes the OA8.

That point matters commercially as much as technically. The OA8 requires a fused interface module or external fusing for output protection, and the cost of one is part of the comparison against the OA8D and OA8E, which carry electronic fusing per point.

Motor-starter capability at 120 V AC/60 Hz is generous for eight points: 8 starters of size 0...1, size 2 and size 3, 8 of size 4 at 30 °C and 6 at 60 °C, and 5 of size 5 at 30 °C and 4 at 60 °C — the same size 4 and 5 capability as the OA16I, on eight points instead of sixteen.

The module belongs to the AC output family with the same published output features: scheduled outputs synchronised within 16.7 seconds to the Coordinated System Time, per-point fault state and program state, and electronic module keying.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OA8
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 8
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OA8 module product photograph 1756-OA8 terminal side product photograph 1756-OA8 module view product photograph

Where the module sits in a typical system

Eight AC outputs in one slot suits small machine sections: a valve bank, a set of contactor coils, or an indicator panel where sixteen points would be half-empty.

Because it reaches size 4 and 5 starters at reduced counts, it also serves as a compact high-capability output where only a few large starters are present.

Its lack of on-module fusing makes the interface decision part of the design: a fused IFM protects the outputs, and the OA8D or OA8E carry that protection inside the module.

Commissioning in five steps

  1. Confirm the load current against the module's per-point rating at the actual cabinet temperature, not at 30 °C. Above 30 °C the OA16I point current derates linearly at about 0.033 A per °C.
  2. Check inrush, not just running current. A contactor or motor starter that draws 1,225 VA inrush per line presents far more than its sealed current, and the module's surge rating is the number that has to cover it.
  3. Decide the fusing arrangement before wiring: the OA16 is mechanically fused per group at 3.15 A, the OA8 family is either electronically fused per point or unprotected, and a fused interface module is recommended where the module itself is unprotected.
  4. Set the fault state and program state per point in the module configuration, so a communication failure drives the outputs to the state the machine needs.
  5. For diagnostic modules, respect the minimum load current — the 1756-OA8D needs at least 10 mA in the on state or its diagnostics cannot sense the load.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 Eight points, size 4 and 5 capable 8 size 4 starters at 30 °C, 6 at 60 °C; 5 size 5 at 30 °C, 4 at 60 °C.
 Check 3 125 V isolation only Outputs-to-backplane is 125 V basic on this module, against 250 V on the OA16 and OA16I. That difference matters at 240 V AC.
 Check 4 Cost comparison Add the external fuse or fused interface module to the OA8 price before comparing it with the OA8D, which fuses per point.
 Check 5 Fault state configuration Per-point fault and program states are set in the project; default off.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a AC output module of an earlier generation

The diagnostic 8-point module is 1756-OA8D, electronically fused per point with a 10 mA minimum load requirement.

The electronically fused 8-point module is 1756-OA8E.

The 16-point group-fused module is 1756-OA16, and the 16-point isolated module is 1756-OA16I.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OA16 — 16 triac outputs, 120/240 V AC at 0.5 A pilot duty, mechanically fused per group at 3.15 A, 1500 A interruption current.
  • 1756-OA16I — 16 isolated triac outputs, 2 A per point at 30 °C derating to 1 A at 60 °C, 5 A per module, 20 A surge.
  • 1756-OA8 — 8 triac outputs with the widest motor-starter table of the family, up to size 5 at reduced ambient.
  • 1756-OA8D — 8 diagnostic outputs, electronically fused per point, 10 mA minimum load.
  • 1756-OA8E — 8 outputs, electronically fused per point.
  • 1756-OW16I — 16 isolated relay contacts, 10...265 V, for loads an AC output will not switch.

FAQ — 1756-OA8 ControlLogix 8 Point AC Output Module | Rockwell

What is the 1756-OA8?

An 8-point AC triac output module, 120/240 V AC at 2 A pilot duty, backplane 200 mA at 5.1 V DC, unfused at module level.

Is it fused?

No. Rockwell's fusing table lists only the OA8D and OA8E as electronically fused per point and the OA16 as mechanically fused per group; the OA8 is not protected, and a fused interface module is recommended.

How many size 5 starters can it drive?

5 at 30 °C and 4 at 60 °C at 120 V AC/60 Hz.

How many size 0...3 starters?

8 starters of each size from 0 to 3 at 120 V AC/60 Hz.

What output voltage range?

120/240 V AC at 50/60 Hz, rated 2 A pilot duty per point.

What is the backplane current?

200 mA at 5.1 V DC and 2 mA at 24 V DC.

How does it differ from the OA8D?

The OA8D is the diagnostic version, electronically fused per point, and requires a minimum load of 10 mA to sense its outputs.

Does it have scheduled outputs?

Yes — the AC output family synchronises scheduled outputs within 16.7 seconds to the Coordinated System Time.

What documents cover it?

1756-IN064 for installation and 1756-UM058 for the module manual and the starter tables.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OA8. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)