The 1756-PBR2 (also written 1756PBR2) is the DC member of the ControlLogix redundant power supply bundle pair: a 19-32 V DC redundant power supply assembly with the connection cables included, catalogued as a bundle rather than as separate supplies.
The assembled output is the redundant pair rating — 13 A at 5.1 V DC, 4 A at 3.3 V DC, 1.5 A at 1.2 V DC and 2.8 A at 24 V DC — with the redundant configuration flag published as true. The 1756-PSCA2 adapter that ships in the assembly passes up to 15 A at 5.1 V DC to the backplane, so the adapter sets the rack ceiling rather than the supplies.
The input window is the reason this part exists next to the AC bundle: 19-32 V DC, which covers a 24 V DC plant rail with its normal tolerance band. 1756-TD005 quotes the low end of the redundant DC supply as 18 V while the product data states 19 V DC, so a marginal 24 V rail is worth checking against the lower figure before the build is fixed.
Published attributes: active lifecycle, country of origin Mexico, UPC 612598313723, one year standard warranty, connection cables included, 2-dimensional drawings available in PDF and DWG/DXF. Documentation is 1756-TD005 and 1756-SG001; the certification entry recorded is China CCC as of 2026-08-11.
| 1756-PA75R | AC redundant supply, 120/240 V AC, 13 A at 5.1 V DC, 75 W | IN STOCK |
| 1756-PB75R | DC redundant supply, 24 V DC, 13 A at 5.1 V DC, 75 W | IN STOCK |
| 1756-PAXT | XT AC supply, 8 A at 5.1 V DC, 42 W at -25 to +70 C | IN STOCK |
| 1756-PBXT | XT DC supply, 10 A at 5.1 V DC, 52 W at -25 to +70 C | IN STOCK |
| 1756-PAXTR | XT AC redundant supply, 42 W, 0-60 C in a non-XT chassis | IN STOCK |
| 1756-PA75 | Non-redundant AC supply, single, 13 A at 5.1 V DC, 75 W | IN STOCK |
Application | Chassis Power |
Brand Name | Rockwell (Rockwell) |
Cat Num | 1756-PBR2 |
Communication | — |
Display | — |
Enclosure | None (open-style) |
Interface | Backplane, via 1756-PSCA2 |
Mounting | Remote, cable-connected |
Number Of Channels | — |
Standard | CE, UL, RCM, EAC, Morocco DOC |
Sub Brand | ControlLogix |
Type | Redundant Power Supply |
UNSPSC | — |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN620 (redundant power supply instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The DC bundle suits plants that already distribute 24 V DC — process skids with a DC bus, telecom and substation rooms, battery-backed panels — where an AC feed would mean adding a transformer or a separate UPS branch for the control rack.
Both supplies sit on the same DC source unless the design deliberately separates them. Two supplies on one 24 V rail protect against a supply failure, not against the rail itself, which is the honest scope of this redundancy.
The assembly is the fastest path to a validated redundant rack: one part number, cables included, and the adapter that the chassis needs. For a project with a commissioning date, that removes three procurement lines from the critical path.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | 24 V rail quality | 19 V DC low limit against 18 V in TD005. Inrush of the supplies plus the rest of the DC distribution can pull the rail below the limit at start-up — measure it, do not assume it. |
| Check 3 | Cables in the box | Connection cables are listed as included. Verify the shipped contents, because the adapter has nothing to connect without them. |
| Check 4 | Chassis series | Published against 1756-A4/C, A7/C, A10/C, A13/C and A17/C — the /C series for the DC redundant supply (1756-IN620). A /B chassis pairs with the AC supply instead. |
| Check 5 | Backplane ceiling | 15 A at 5.1 V DC through the adapter, against 13 A from the supply pair. The rack load budget is capped by the adapter, not by the supplies. |
| Check 6 | Enclosure and heat | Supplies mount remotely, keeping their heat out of the chassis. Cable length (0.91 m standard) and the 12.7 cm bend radius drive the enclosure layout. |
Installation checks per Rockwell publication 1756-IN620, which covers adapter mounting, cable seating, load sharing, fusing and the chassis compatibility table and 1756-IN050.
The AC counterpart is 1756-PAR2: same bundle structure, 85-265 V AC input, same 13 A at 5.1 V DC pair rating, published against the 1756-A4/B…A17/B chassis.
Components remain individually orderable: 1756-PB75R for a single supply, 1756-PSCA2 for the adapter and 1756-CPR2 (0.91 m) for the cable. The XT redundant DC part is 1756-PBXTR with the 1756-PSCA2XT adapter, rated 0…60 °C in a non-XT chassis.
Do not substitute a standard 1756-PB75 supply for one member of the pair. The redundant supplies share current through the adapter and are characterised as a redundant pair; mixing a non-redundant supply in breaks the arrangement the assembly was certified as.
What is the 1756-PBR2?
A ControlLogix Power Supply Bundle — the 19-32 V DC redundant power supply assembly — with the connection cables included, catalogued as one item rather than as two supplies plus an adapter and cables.
What output does the assembly provide?
13 A at 5.1 V DC, 4 A at 3.3 V DC, 1.5 A at 1.2 V DC and 2.8 A at 24 V DC for the pair, with the 1756-PSCA2 adapter passing up to 15 A at 5.1 V DC to the backplane.
What input voltage is required?
19-32 V DC per the published product data; 1756-TD005 states the low end of the redundant DC supply as 18 V, so a marginal rail should be assessed against the lower figure.
Which chassis does it fit?
1756-A4/C, A7/C, A10/C, A13/C and A17/C — the /C series chassis published for the DC redundant supply in 1756-IN620.
Does redundancy cover the adapter and cables?
No. The redundant system is designed to account for operational anomalies in the power supply only, with the chassis adapter and cables explicitly excluded.
Are the cables really included?
Rockwell lists connection cables as included for this catalogue number. Confirm the physical contents at goods-in, because an assembly without its cables cannot be installed.
What happens on a single supply failure?
The second supply carries the full chassis load without interruption. The fault is only visible on the annunciator contacts, wired by the user up to 10 m (32.8 ft).
Can both supplies be on the same 24 V source?
Yes, and that is common. It protects against supply failure but not against loss of the 24 V rail itself, so the source needs its own resilience if the process depends on it.
Where can I get drawings and data?
2-dimensional drawings are published in PDF and DWG/DXF, technical data in 1756-TD005, and selection guidance in 1756-SG001. UPC 612598313723, country of origin Mexico.
Data sources. Technical values on this page come from Rockwell publications 1756-IN620 (ControlLogix Redundant Power Supply, installation instructions), 1756-IN619 (ControlLogix Power Supply installation instructions) and 1756-TD005 (ControlLogix power supply technical data) and the manufacturer's product page for 1756-PBR2. Values re-checked 15 November 2026.