logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-PBR2 / 1756PBR2

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-PBR2 / 1756PBR2

China Allen Bradley PLC 1756-PBR2 / 1756PBR2 supplier
Allen Bradley PLC 1756-PBR2 / 1756PBR2 supplier Allen Bradley PLC 1756-PBR2 / 1756PBR2 supplier Allen Bradley PLC 1756-PBR2 / 1756PBR2 supplier Allen Bradley PLC 1756-PBR2 / 1756PBR2 supplier Allen Bradley PLC 1756-PBR2 / 1756PBR2 supplier

Large Image :  Allen Bradley PLC 1756-PBR2 / 1756PBR2

Product Details:

Place of Origin: Made in MEXICO
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-PBR2 / 1756PBR2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1508.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description


1756-PBR2 technical data PDF download 1756-PBR2 ControlLogix DC Redundant Power Supply Bundle | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-PBR2 (also written 1756PBR2) is the DC member of the ControlLogix redundant power supply bundle pair: a 19-32 V DC redundant power supply assembly with the connection cables included, catalogued as a bundle rather than as separate supplies.

The assembled output is the redundant pair rating — 13 A at 5.1 V DC, 4 A at 3.3 V DC, 1.5 A at 1.2 V DC and 2.8 A at 24 V DC — with the redundant configuration flag published as true. The 1756-PSCA2 adapter that ships in the assembly passes up to 15 A at 5.1 V DC to the backplane, so the adapter sets the rack ceiling rather than the supplies.

The input window is the reason this part exists next to the AC bundle: 19-32 V DC, which covers a 24 V DC plant rail with its normal tolerance band. 1756-TD005 quotes the low end of the redundant DC supply as 18 V while the product data states 19 V DC, so a marginal 24 V rail is worth checking against the lower figure before the build is fixed.

Published attributes: active lifecycle, country of origin Mexico, UPC 612598313723, one year standard warranty, connection cables included, 2-dimensional drawings available in PDF and DWG/DXF. Documentation is 1756-TD005 and 1756-SG001; the certification entry recorded is China CCC as of 2026-08-11.

1756-PA75RAC redundant supply, 120/240 V AC, 13 A at 5.1 V DC, 75 WIN STOCK
1756-PB75RDC redundant supply, 24 V DC, 13 A at 5.1 V DC, 75 WIN STOCK
1756-PAXTXT AC supply, 8 A at 5.1 V DC, 42 W at -25 to +70 CIN STOCK
1756-PBXTXT DC supply, 10 A at 5.1 V DC, 52 W at -25 to +70 CIN STOCK
1756-PAXTRXT AC redundant supply, 42 W, 0-60 C in a non-XT chassisIN STOCK
1756-PA75Non-redundant AC supply, single, 13 A at 5.1 V DC, 75 WIN STOCK

 Application
 Chassis Power
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-PBR2
 Communication
 —
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Backplane, via 1756-PSCA2
 Mounting
 Remote, cable-connected
 Number Of Channels
 —
 Standard
 CE, UL, RCM, EAC, Morocco DOC
 Sub Brand
 ControlLogix
 Type
 Redundant Power Supply
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN620 (redundant power supply instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-PBR2 redundant DC supply bundle product photograph 1756-PBR2 supply pair product photograph 1756-PBR2 assembly detail product photograph

Where the module sits in a typical system

The DC bundle suits plants that already distribute 24 V DC — process skids with a DC bus, telecom and substation rooms, battery-backed panels — where an AC feed would mean adding a transformer or a separate UPS branch for the control rack.

Both supplies sit on the same DC source unless the design deliberately separates them. Two supplies on one 24 V rail protect against a supply failure, not against the rail itself, which is the honest scope of this redundancy.

The assembly is the fastest path to a validated redundant rack: one part number, cables included, and the adapter that the chassis needs. For a project with a commissioning date, that removes three procurement lines from the critical path.

Commissioning in five steps

  1. Mount the two supplies remotely and land both on the 1756-PSCA2 chassis adapter: the adapter is a passive device and simply funnels power from one or two supplies into the single backplane power connector.
  2. Use the published cable — 1756-CPR2, 1756-CPR2D or 1756-CPR2U — and never connect or disconnect it while either backplane power source is energised: an arc at the connector is an explosion hazard in a classified area and wears the contacts.
  3. Wire the mains side with 2.5 mm² (14 AWG) 90 °C copper at 1.2 mm insulation maximum, tighten to 0.565 N·m (5 lb·in), and protect every ungrounded supply with a 15 A time-delay fuse.
  4. Keep annunciator wiring to 10 m (32.8 ft) maximum if you use the annunciator contacts, and note the wire categories: category 1 on the power ports and category 3 on the 1756-CPR2 connections.
  5. Commission by load: with both supplies healthy the pair shares the chassis current, so confirm the sharing before you rely on it. A single healthy supply must carry the entire chassis load — that is the design promise, not a margin.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 24 V rail quality 19 V DC low limit against 18 V in TD005. Inrush of the supplies plus the rest of the DC distribution can pull the rail below the limit at start-up — measure it, do not assume it.
 Check 3 Cables in the box Connection cables are listed as included. Verify the shipped contents, because the adapter has nothing to connect without them.
 Check 4 Chassis series Published against 1756-A4/C, A7/C, A10/C, A13/C and A17/C — the /C series for the DC redundant supply (1756-IN620). A /B chassis pairs with the AC supply instead.
 Check 5 Backplane ceiling 15 A at 5.1 V DC through the adapter, against 13 A from the supply pair. The rack load budget is capped by the adapter, not by the supplies.
 Check 6 Enclosure and heat Supplies mount remotely, keeping their heat out of the chassis. Cable length (0.91 m standard) and the 12.7 cm bend radius drive the enclosure layout.

Installation checks per Rockwell publication 1756-IN620, which covers adapter mounting, cable seating, load sharing, fusing and the chassis compatibility table and 1756-IN050.

Replacing a 1756-ENBT

The AC counterpart is 1756-PAR2: same bundle structure, 85-265 V AC input, same 13 A at 5.1 V DC pair rating, published against the 1756-A4/B…A17/B chassis.

Components remain individually orderable: 1756-PB75R for a single supply, 1756-PSCA2 for the adapter and 1756-CPR2 (0.91 m) for the cable. The XT redundant DC part is 1756-PBXTR with the 1756-PSCA2XT adapter, rated 0…60 °C in a non-XT chassis.

Do not substitute a standard 1756-PB75 supply for one member of the pair. The redundant supplies share current through the adapter and are characterised as a redundant pair; mixing a non-redundant supply in breaks the arrangement the assembly was certified as.

Which ControlLogix redundant power supply to specify

  • 1756-PA75R — AC redundant supply, 120/240 V AC nominal, 5.1 V DC at 13 A, 75 W maximum, pairs into chassis A4/B…A17/B.
  • 1756-PB75R — DC redundant supply, 24 V DC nominal (18 V minimum at the input), 5.1 V DC at 13 A, 75 W maximum, pairs into chassis A4/C…A17/C.
  • 1756-PAXTR / 1756-PBXTR — the XT redundant pair; rated 0…60 °C only when mounted in a non-XT chassis.
  • 1756-PSCA2 / 1756-PSCA2XT — the passive chassis adapter the supplies feed; one per chassis, two supply cables land on it.
  • 1756-CPR2 — the 0.91 m (3 ft) redundant supply cable; also offered as 1756-CPR2D and 1756-CPR2U.
  • 1756-PA75 / 1756-PB75 — the non-redundant single supplies; same 75 W class, no second supply and no adapter.

FAQ — 1756-PBR2 ControlLogix DC Redundant Power Supply Bundle | Rockwell

What is the 1756-PBR2?

A ControlLogix Power Supply Bundle — the 19-32 V DC redundant power supply assembly — with the connection cables included, catalogued as one item rather than as two supplies plus an adapter and cables.

What output does the assembly provide?

13 A at 5.1 V DC, 4 A at 3.3 V DC, 1.5 A at 1.2 V DC and 2.8 A at 24 V DC for the pair, with the 1756-PSCA2 adapter passing up to 15 A at 5.1 V DC to the backplane.

What input voltage is required?

19-32 V DC per the published product data; 1756-TD005 states the low end of the redundant DC supply as 18 V, so a marginal rail should be assessed against the lower figure.

Which chassis does it fit?

1756-A4/C, A7/C, A10/C, A13/C and A17/C — the /C series chassis published for the DC redundant supply in 1756-IN620.

Does redundancy cover the adapter and cables?

No. The redundant system is designed to account for operational anomalies in the power supply only, with the chassis adapter and cables explicitly excluded.

Are the cables really included?

Rockwell lists connection cables as included for this catalogue number. Confirm the physical contents at goods-in, because an assembly without its cables cannot be installed.

What happens on a single supply failure?

The second supply carries the full chassis load without interruption. The fault is only visible on the annunciator contacts, wired by the user up to 10 m (32.8 ft).

Can both supplies be on the same 24 V source?

Yes, and that is common. It protects against supply failure but not against loss of the 24 V rail itself, so the source needs its own resilience if the process depends on it.

Where can I get drawings and data?

2-dimensional drawings are published in PDF and DWG/DXF, technical data in 1756-TD005, and selection guidance in 1756-SG001. UPC 612598313723, country of origin Mexico.


Data sources. Technical values on this page come from Rockwell publications 1756-IN620 (ControlLogix Redundant Power Supply, installation instructions), 1756-IN619 (ControlLogix Power Supply installation instructions) and 1756-TD005 (ControlLogix power supply technical data) and the manufacturer's product page for 1756-PBR2. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956