logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-PAXT / 1756PAXT

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-PAXT / 1756PAXT

China Allen Bradley PLC 1756-PAXT / 1756PAXT supplier
Allen Bradley PLC 1756-PAXT / 1756PAXT supplier Allen Bradley PLC 1756-PAXT / 1756PAXT supplier Allen Bradley PLC 1756-PAXT / 1756PAXT supplier Allen Bradley PLC 1756-PAXT / 1756PAXT supplier Allen Bradley PLC 1756-PAXT / 1756PAXT supplier Allen Bradley PLC 1756-PAXT / 1756PAXT supplier

Large Image :  Allen Bradley PLC 1756-PAXT / 1756PAXT

Product Details:

Place of Origin: Made in MEXICO
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-PAXT / 1756PAXT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $738.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-PAXT technical data PDF download 1756-PAXT ControlLogix-XT AC Power Supply | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-PAXT (also written 1756PAXT) is the AC power supply of the ControlLogix-XT family: a single, chassis-mounted supply rated 42 W at 5.1 V DC from -25…+70 °C, for a chassis that has to run outside the 0…60 °C envelope of the standard ControlLogix hardware. Rockwell publishes it as an 85-265 V AC supply with 120/240 V AC nominal input and a 47…63 Hz input frequency range (1756-TD005, 1756-IN619).

The output is the number that decides the design: 42 W maximum, 8 A at 5.1 V DC, 4 A at 3.3 V DC, 1.75 A at 24 V DC and 1.5 A at 1.2 V DC. That is roughly half the 75 W of a standard 1756-PA75, which is the trade-off the XT rating buys — the same chassis and the same module set, but a smaller power envelope and an extended temperature window.

Electrical and mechanical data: 85…265 V AC input range, 82 VA / 64 W maximum input power, 20 A maximum inrush, 250 V continuous reinforced insulation from the power input to the backplane, type tested at 3260 V DC for 60 s, 0.95 kg, and the same 14.0 x 7.8 x 14.5 cm footprint as the standard supply. The published chassis pairing is the XT list — 1756-A4LXT/B, 1756-A5XT/B, 1756-A7LXT/B and 1756-A7XT/B — not the standard A4…A17 chassis.

1756-PA75RAC redundant supply, 120/240 V AC, 13 A at 5.1 V DC, 75 WIN STOCK
1756-PB75RDC redundant supply, 24 V DC, 13 A at 5.1 V DC, 75 WIN STOCK
1756-PAXTXT AC supply, 8 A at 5.1 V DC, 42 W at -25 to +70 CIN STOCK
1756-PBXTXT DC supply, 10 A at 5.1 V DC, 52 W at -25 to +70 CIN STOCK
1756-PAXTRXT AC redundant supply, 42 W, 0-60 C in a non-XT chassisIN STOCK
1756-PA75Non-redundant AC supply, single, 13 A at 5.1 V DC, 75 WIN STOCK

 Application
 Chassis Power
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-PAXT
 Communication
 —
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Backplane, via 1756-PSCA2
 Mounting
 Remote, cable-connected
 Number Of Channels
 —
 Standard
 CE, UL, RCM, EAC, Morocco DOC
 Sub Brand
 ControlLogix
 Type
 Redundant Power Supply
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN620 (redundant power supply instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-PAXT XT power supply product photograph 1756-PAXT supply front product photograph 1756-PAXT terminals product photograph

Where the module sits in a typical system

The part is specified for the edge of the envelope: an outdoor cabinet, a skid in a cold climate, a wash-down area with a heated enclosure, or a machine that starts at -20 °C and runs at 60 °C inside the panel. In those cases the whole chassis is XT hardware, and the supply is the last item on the list that still has to match.

The power budget is the engineering decision. Because 42 W is the ceiling, XT panels are usually built with fewer comms modules and a lean module set, and the supply choice is settled before the module list rather than after it. Splitting a large XT cell across two chassis is the usual answer when the 42 W does not cover the design.

There is no redundant version in this exact class: the XT redundant supplies are the 1756-PAXTR and 1756-PBXTR pair, which are rated 42 W and 52 W at 0…60 °C in a non-XT chassis. If the application needs both redundancy and the XT window, confirm the chassis and supply combination against the published tables rather than assuming the two features stack.

Commissioning in five steps

  1. Mount the two supplies remotely and land both on the 1756-PSCA2 chassis adapter: the adapter is a passive device and simply funnels power from one or two supplies into the single backplane power connector.
  2. Use the published cable — 1756-CPR2, 1756-CPR2D or 1756-CPR2U — and never connect or disconnect it while either backplane power source is energised: an arc at the connector is an explosion hazard in a classified area and wears the contacts.
  3. Wire the mains side with 2.5 mm² (14 AWG) 90 °C copper at 1.2 mm insulation maximum, tighten to 0.565 N·m (5 lb·in), and protect every ungrounded supply with a 15 A time-delay fuse.
  4. Keep annunciator wiring to 10 m (32.8 ft) maximum if you use the annunciator contacts, and note the wire categories: category 1 on the power ports and category 3 on the 1756-CPR2 connections.
  5. Commission by load: with both supplies healthy the pair shares the chassis current, so confirm the sharing before you rely on it. A single healthy supply must carry the entire chassis load — that is the design promise, not a margin.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 Budget 42 W, not 75 W Add the 5.1 V, 3.3 V, 24 V and 1.2 V draws of every module and keep the total under 42 W at 70 °C. A module set that fits a 1756-PA75 will not necessarily fit here.
 Check 3 Input branch 85…265 V AC, 47…63 Hz, 20 A maximum inrush. Size the branch protection and the transformer for the inrush, not for the 64 W steady input.
 Check 4 Terminals and torque 2.5 mm² (14 AWG) 90 °C copper, 1.2 mm maximum insulation, 0.565 N·m (5 lb·in) torque, one conductor per terminal.
 Check 5 Hazardous-area documentation Rockwell's product page for 1756-PAXT lists an ATEX declaration of conformity, and 1756-TD005 prints the XT protection type II 3 G Ex ec IIC T4 Gc for the XT supplies. No IECEx entry appears for this catalogue number, so a Zone 2 claim is quoted from the certificate on the unit, not from the family name.
 Check 6 Derating at the top of the range 42 W is stated at -25…+70 °C. Verify the enclosure actually reaches the mounted ambient you are claiming — an XT supply does not extend the rating of the modules around it.

Installation checks per Rockwell publication 1756-IN620, which covers adapter mounting, cable seating, load sharing, fusing and the chassis compatibility table and 1756-IN050.

Replacing a 1756-ENBT

The 1756-PAXT is the AC XT supply; its DC counterpart is the 1756-PBXT at 52 W and 10 A at 5.1 V DC. Swapping from AC to DC changes the input terminals, the branch protection and the inrush figure (20 A against 30 A), so it is a wiring change as well as a part change.

For a redundant XT arrangement the published parts are 1756-PAXTR and 1756-PBXTR with the 1756-PSCA2XT adapter and 1756-CPR2 cables. Keep that in mind when a single 1756-PAXT is replaced: the redundancy is a different bill of materials, not an option on this supply.

A failed supply is a chassis-level stop, because there is no second supply in this configuration. That is the reason the redundant family exists, and the reason a single-supply XT panel should carry a spare supply rather than a spare module.

Which ControlLogix-XT power supply to specify

  • 1756-PA75R — AC redundant supply, 120/240 V AC nominal, 5.1 V DC at 13 A, 75 W maximum, pairs into chassis A4/B…A17/B.
  • 1756-PB75R — DC redundant supply, 24 V DC nominal (18 V minimum at the input), 5.1 V DC at 13 A, 75 W maximum, pairs into chassis A4/C…A17/C.
  • 1756-PAXTR / 1756-PBXTR — the XT redundant pair; rated 0…60 °C only when mounted in a non-XT chassis.
  • 1756-PSCA2 / 1756-PSCA2XT — the passive chassis adapter the supplies feed; one per chassis, two supply cables land on it.
  • 1756-CPR2 — the 0.91 m (3 ft) redundant supply cable; also offered as 1756-CPR2D and 1756-CPR2U.
  • 1756-PA75 / 1756-PB75 — the non-redundant single supplies; same 75 W class, no second supply and no adapter.

FAQ — 1756-PAXT ControlLogix-XT AC Power Supply | Rockwell

What is the temperature rating of the 1756-PAXT?

42 W maximum output at -25…+70 °C (-13…+158 °F), against 0…60 °C for the standard ControlLogix supplies. The extended window is the reason the XT part exists (1756-TD005).

How much 5.1 V current is available?

8 A at 5.1 V DC, with 4 A at 3.3 V DC, 1.75 A at 24 V DC and 1.5 A at 1.2 V DC, for a 42 W maximum output. A standard 1756-PA75 offers 13 A at 5.1 V DC and 75 W, so the XT rating costs roughly half the power envelope.

Which chassis does it fit?

The XT chassis list: 1756-A4LXT/B, 1756-A5XT/B, 1756-A7LXT/B and 1756-A7XT/B. It is not listed for the standard A4…A17 chassis family (1756-IN619).

What are the input ratings?

85…265 V AC range, 120/240 V AC nominal, 47…63 Hz, 82 VA and 64 W maximum input power, 20 A maximum inrush current.

Does it carry ATEX or IECEx approval?

Rockwell lists an ATEX declaration of conformity for 1756-PAXT; no IECEx entry is listed for this catalogue number. 1756-TD005 prints the protection type II 3 G Ex ec IIC T4 Gc with certificate UL 22 ATEX 2819X for the XT supplies, so a Zone 2 installation should quote the certificate on the unit rather than assume the whole family shares it.

Which certifications does it hold?

CE to 2014/30/EU EMC and 2014/35/EU LVD (EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2 clause 11), UKCA, Australian RCM, EAC, American Bureau of Shipping, ATEX declaration of conformity, and UL/c-UL-us safety certification; the 1756-TD005 XT tables also list China CCC for the family.

What is the isolation rating?

250 V continuous, reinforced insulation type, power input to backplane, type tested at 3260 V DC for 60 s.

What are the physical details?

0.95 kg, 14.0 x 7.8 x 14.5 cm (H x W x D) — the same footprint as the standard supplies — with 2.5 mm² (14 AWG) 90 °C copper terminals at 0.565 N·m torque and open-style enclosure.

What is the redundant alternative if I need both XT and redundancy?

The published XT redundant supplies are 1756-PAXTR (42 W, 8 A at 5.1 V DC) and 1756-PBXTR (52 W, 10 A at 5.1 V DC), and both are rated 0…60 °C only when used in a non-XT chassis. The chassis and supply combination has to be checked against the tables, not assumed.


Data sources. Technical values on this page come from Rockwell publications 1756-IN620 (ControlLogix Redundant Power Supply, installation instructions), 1756-IN619 (ControlLogix Power Supply installation instructions) and 1756-TD005 (ControlLogix power supply technical data) and the manufacturer's product page for 1756-PAXT. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)