Product Details:
Payment & Shipping Terms:
|
The 1756-M16SE (also written 1756M16SE) is the sixteen-drive SERCOS interface module — one slot, one fibre ring, sixteen axes in position, velocity or torque, with the drive diagnostics arriving on the same link.
Published figures: 16 drives maximum, 8 Mbps, 760 mA at 5.1 V DC and 2.5 mA at 24 V DC, 5.0 W, one slot in any 1756 chassis, 0…60 °C (1756-TD004). Sixteen drives is the largest ring in the family and the point at which the 2 ms cycle time becomes the design assumption: 0.5 ms up to 4 drives, 1 ms up to 8 and 2 ms up to 16 at 8 Mbps.
| 1756-M02AE | 2-axis analog servo module, incremental quadrature feedback | IN STOCK |
| 1756-M02AS | 2-axis analog servo module, SSI absolute feedback 8…31 bits | IN STOCK |
| 1756-HYD02 | 2-axis analog hydraulic servo module, LDT feedback | IN STOCK |
| 1756-M03SE | SERCOS module, 3 drives, position / velocity / torque | IN STOCK |
| 1756-M08SE | SERCOS module, 8 drives, position / velocity / torque | IN STOCK |
| 1756-M16SE | SERCOS module, 16 drives, position / velocity / torque | IN STOCK |
| 1756-M08SEG | SERCOS module, 8 Extended Pack Profile drives, position only | IN STOCK |
Application |
SERCOS interface motion |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-M16SE |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-M16SE |
Mounting |
Chassis |
Number Of Channels |
1756-M16SE |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Motion control module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Sixteen axes is a multi-station line: an indexer, several forming or filling stations, the transfer axes between them and the auxiliary axes that the mechanical design adds late. One module on one ring means one fibre pair to pull and one place to look when an axis drops out.
The limit to design against is the cycle time, not the drive count. Sixteen drives at 8 Mbps run at 2 ms in the published table; a line that needs 1 ms on all sixteen has to be split over two modules, because the ring is one serial loop and the cycle time is shared by every drive on it.
These are the published signal levels and limits of the module — the figures to measure against at the terminals and in the axis configuration, taken from 1756-TD004 rather than from a generic commissioning checklist.
| Indicator | State | Meaning and first action |
| SERCOS data rate | 8 Mbps | The rate the module runs at; the cycle time below is tied to it, not to the drive count alone. |
| Cycle time at 4 Mbps | 0.5 ms / 1 ms / 2 ms | 0.5 ms up to 2 drives, 1 ms up to 4 drives, 2 ms up to 8 drives. Kinetix 6000 drives allow the 0.5 ms figure. |
| Cycle time at 8 Mbps | 0.5 ms / 1 ms / 2 ms | 0.5 ms up to 4 drives, 1 ms up to 8 drives, 2 ms up to 16 drives. |
| Drive control modes | Position, velocity, and torque | The modes this module commands; a drive configured outside them will not run from this module. |
| Fibre link | Plastic or glass | 2090-SCEPxx-0 non-jacketed CPE, 2090-SCVPxx-0 PVC jacket, 2090-SCNPxx-0 nylon jacket for plastic; 2090-SCVGxx-0 PVC jacket for glass. |
| Supported drives | 2093 / 2094 / 2099 / 2098 | Kinetix 2000, Kinetix 6000, Kinetix 7000 and Ultra3000 SERCOS drives are the drives named in the specification. |
| Slot load | 760 mA at 5.1 V DC | Plus 2.5 mA at 24 V DC and 5.0 W dissipation; count it against the chassis supply before adding I/O. |
| Operating temperature | 0…60 °C | Storage -40…85 °C, 5…95% relative humidity noncondensing, 2 g vibration at 10…500 Hz, 30 g operating shock. |
Signal levels, loop rates, rates and terminal block data per Rockwell publication 1756-TD004B-EN-E (1756 ControlLogix Integrated Motion Modules Specifications) and 1756-IN050.
The M16SE is the top of the SERCOS family and the replacement for a rack that outgrew an M08SE. Same slot, same fibre, same drive list: the ring is re-addressed and the axis configuration is re-checked, the cabinet does not change.
Where the machine is new rather than converted, the axis count usually decides the module before anything else; the analog modules are chosen only when the drive cannot take a SERCOS interface.
What is the maximum number of drives on the 1756-M16SE?
16 drives on one SERCOS fibre ring (1756-TD004).
What cycle time applies with 16 drives?
2 ms at 8 Mbps is the published point for up to 16 drives; 1 ms covers up to 8 drives and 0.5 ms up to 4.
What is the data rate?
8 Mbps, the rate printed for the 1756-M08SE, M16SE and M08SEG, against 4 Mbps for the 1756-M03SE.
What does the module draw?
760 mA at 5.1 V DC and 2.5 mA at 24 V DC, 5.0 W dissipation, one slot in any 1756 chassis.
What control modes does it support?
Position, velocity and torque, the same as the M03SE and M08SE.
How long can the fibre run be?
The specification publishes the cable types, not a length: plastic 2090-SCEPxx-0 / SCVPxx-0 / SCNPxx-0, glass 2090-SCVGxx-0. The ring length is set by the cable ordered and the drive layout.
Which drives can be connected?
2093 Kinetix 2000, 2094 Kinetix 6000, 2099 Kinetix 7000 and 2098 Ultra3000 SERCOS drives.
What certifications does it carry?
UL Listed industrial control equipment (UL file E65584), UL Listed for Class I Division 2 Groups A, B, C, D (E194810), CE to EN 61326-1 / EN 61000-6-2 / EN 61131-2 / EN 61000-6-4 and C-Tick to AS/NZS CISPR 11, when marked.
Data sources. Technical values on this page come from Rockwell publications 1756-TD004 (1756 ControlLogix Integrated Motion Modules Specifications). A single specification document covers the SERCOS and analog motion families, so the numbers on this page can be checked line by line in the manufacturer's table. and the manufacturer's product page for 1756-M16SE. Values re-checked 16 November 2026.