logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IB16D / 1756IB16D

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IB16D / 1756IB16D

China Allen Bradley PLC 1756-IB16D / 1756IB16D supplier
Allen Bradley PLC 1756-IB16D / 1756IB16D supplier Allen Bradley PLC 1756-IB16D / 1756IB16D supplier Allen Bradley PLC 1756-IB16D / 1756IB16D supplier Allen Bradley PLC 1756-IB16D / 1756IB16D supplier Allen Bradley PLC 1756-IB16D / 1756IB16D supplier

Large Image :  Allen Bradley PLC 1756-IB16D / 1756IB16D

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IB16D / 1756IB16D

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $363.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IB16D technical data PDF download 1756-IB16D ControlLogix 16 Point Diagnostic DC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IB16D (also written 1756IB16D) is the diagnostic version of the 16-point DC input module: operating range 10...30 V DC, maximum input current 13 mA, backplane load 150 mA at 5.1 V DC and 3 mA at 24 V DC (1756-IN062).

The difference from the 1756-IB16 is not a refinement — it is a change of purpose. The D variant carries channel diagnostics, which is why its input window is 10...30 V DC rather than 10...31.2 V DC, its input current is 13 mA rather than 10 mA and its backplane draw is 150 mA rather than 100 mA. Diagnostics are paid for in all three figures.

Isolation is 250 V continuous basic insulation from inputs to backplane and between input groups, with no isolation between the individual inputs of a group — one step below the reinforced rating of the IB16, and the reason a plant standard has to pick one or the other rather than alternate.

Published record: active lifecycle, estimated lead time 5 days, one year warranty. Technical data 1756-TD002, user manual 1756-UM058, installation instructions 1756-IN062. Confirm the UPC against the product label at dispatch if a customs document requires it.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IB16D
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IB16D diagnostic input product photograph 1756-IB16D terminal side product photograph 1756-IB16D module view product photograph

Where the module sits in a typical system

The module is chosen where a stuck-at input has to be distinguished from a field device that is simply off — typically safety-adjacent circuits, interlock monitoring and machines where a false input causes scrap rather than a stop.

Diagnostics are not free, and the published figures show the cost: a narrower input range, higher input current and 50 % more backplane load than the non-diagnostic module.

In a panel that mixes both, keep them on separate field circuits. Mixing IB16 and IB16D on one machine means two voltage windows and two current burdens in the same documentation set.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  13 mA per point  Higher input current than the IB16's 10 mA. On a loop-powered device near its limit, that difference matters.
 Check 3  150 mA backplane  50 % more than the IB16 per module. In a chassis full of input modules this is the line that decides the supply.
 Check 4  Basic, not reinforced  250 V basic inputs-to-backplane. Where a reinforced rating is specified, the IB16 is the correct module.
 Check 5  Diagnostics need configuration  Channel diagnostics report through the project. A module installed without the diagnostic configuration in Logix Designer behaves like an ordinary input and reports nothing.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The non-diagnostic equivalent is 1756-IB16: 10...31.2 V DC, 10 mA, 100 mA backplane, reinforced isolation.

The individually isolated option is 1756-IB16I, with isolation input-to-input at 135 mA backplane.

For time-stamped sequence-of-events capture, 1756-IB16ISOE accepts 10...55 V DC at 5.1 mA and draws 320 mA at 5.1 V DC.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IB16D ControlLogix 16 Point Diagnostic DC Input | Rockwell

What is the 1756-IB16D?

A 16-point diagnostic sinking DC input module, 10...30 V DC, 13 mA maximum input current.

How is it different from the 1756-IB16?

It adds channel diagnostics, and its published figures differ: 10...30 V DC instead of 10...31.2 V DC, 13 mA instead of 10 mA, 150 mA backplane instead of 100 mA.

What is the backplane current?

150 mA at 5.1 V DC and 3 mA at 24 V DC.

What isolation does it provide?

250 V continuous basic insulation inputs-to-backplane and between input groups, with no isolation between individual inputs in a group.

Why does diagnostics cost backplane current?

The diagnostic circuitry draws from the backplane in addition to the input path, which is why the published figure is higher than the plain module.

Does it need configuration?

Yes — the diagnostics are configured in the Logix Designer project; without that the module reports nothing.

Can I use a 31 V field supply?

No. The IB16D range ends at 30 V DC, while the IB16 ends at 31.2 V DC.

What documents cover it?

1756-TD002 for technical data, 1756-UM058 for the user manual and 1756-IN062 for installation.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IB16D. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)