Product Details:
Payment & Shipping Terms:
|
The 1794-TB32 is the 32-point cage-clamp base: 32 I/O terminals, 8 common and 8 +V, rated to 31.2V DC and used with the 32-point digital cards and the 1794-IB16D.
The terminal count is the reason it exists — a 32-point module cannot be landed on a 16-terminal base, and the voltage limit is what keeps the base inside a DC-only application.
| 1794-TB2 | 16-terminal cage clamp base, 2-wire, up to 132V AC | IN STOCK |
| 1794-TB3 | 16-terminal cage clamp base, 3-wire devices | IN STOCK |
| 1794-TB3S | 16-terminal spring clamp base, 3-wire devices | IN STOCK |
| 1794-TB32 | 32-terminal cage clamp base for 32-point modules | IN STOCK |
| 1794-TB32S | 32-terminal spring clamp base for 32-point modules | IN STOCK |
| 1794-TB3T | temperature base with two cold junction compensation sets | IN STOCK |
| 1794-TB3TS | spring clamp temperature base with CJC sets | IN STOCK |
| 1794-TB3G | grounded screw clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TB3GS | grounded spring clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TBKD | cage clamp base with 16 knife disconnects | IN STOCK |
| 1794-TBN | NEMA-style screw clamp base, up to 264V AC/DC | IN STOCK |
| 1794-TBNF | fused NEMA-style base, eight 5 x 20 mm fuses | IN STOCK |
| 1794-TB37DS | 37-pin D-shell termination for digital and analog modules | IN STOCK |
| 1794-TB62DS | 62-pin D-shell termination for digital and analog modules | IN STOCK |
Application |
FLEX I/O terminal base for 32-point modules, 1794 backplane |
Cat Num |
1794-TB32 |
Brand Name |
Rockwell |
Termination |
Cage clamp, 32 I/O, 8 common, 8 +V |
Wire size |
0.21...1.3 mm2 (24...16 AWG) stranded, 105 deg C or greater |
Current capacity |
10 A maximum |
Voltage |
Up to 31.2V DC |
Dimensions |
94 x 94 x 69 mm |
Operating temperature |
-20...70 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
32 I/O, 8 common and 8 +V terminals in one base, matching the 1794-OB32P, 1794-OV32 and 1794-IB32 cards.
The selection guide also lists it for the 1794-IB16D, which uses the extra terminals for its diagnostic returns.
8 common and 8 +V rather than the 18 of the 16-point base: the terminals are distributed across the field devices rather than repeated.
10 A maximum base current , and 24...16 AWG stranded wire rated 105 deg C or greater.
Up to 31.2V DC only — this base has no AC rating, so it belongs on 24V DC digital cards.
0.21...1.3 mm2 wire is a narrower window than the 1794-TB3's 0.34...3.3 mm2, which matters on a retrofit where existing conductors are heavier.
-20...70 deg C operating range matches the wider base family.
94 x 94 x 69 mm — same footprint as the 16-point base, so the rail length is set by the module count, not by the terminal count.
32-point digital modules, sink or source, in a 24V DC panel.
1794-IB16D diagnostic inputs, which the selection guide names explicitly.
Not for AC modules, which need a base rated to 132V AC.
Not for 16-point cards, where the terminal count would be wasted and the wire gauge window narrower.
35 x 7.5 mm DIN rail with 25 mm air space around the system.
Zinc-plated, yellow-chromated steel rail for chassis grounding through the rail.
1794-NM1 panel-mount kit and 1492-EA35 DIN rail locks for high-vibration installations.
Bases plug together to form the backplane, with one end cap per system.
Dense 24V DC islands built on 32-point cards.
Diagnostic input groups using the 1794-IB16D.
Not for AC or 125V DC circuits; the 1794-TB3 and 1794-TBN cover those.
Not for spring termination; the 1794-TB32S is the spring version.
How many terminals has the 1794-TB32?
32 I/O, 8 common and 8 +V, in a cage clamp.
What voltage is it rated for?
Up to 31.2V DC; it has no AC rating.
What wire size does it accept?
0.21...1.3 mm2 (24...16 AWG) stranded, 105 deg C or greater.
Which modules use it?
32-point digital cards and the 1794-IB16D diagnostic input module.
What current can it carry?
10 A maximum.
What is the operating temperature?
-20...70 deg C.
1794-TB32 is a FLEX I/O terminal base unit, not an I/O module. It is the part that carries the field terminals, plugs into the adjacent base to form the backplane, and holds the module on top. The termination type here is Cage clamp with 32 I/O, 8 common, 8 +V.
| Attribute | Value |
| Catalog number | 1794-TB32 |
| Termination type | Cage clamp |
| Connections | 32 I/O, 8 common, 8 +V |
| Current capacity, maximum | 10 A |
| Wiring category | module dependent |
| Field voltage | Up to 31.2V DC |
| Operating temperature | -20...+70 C |
| Purpose in the range | A 32-point version of the 1794-TB3 for 32-point digital modules and for the 1794-IB16D diagnostic input module. |
The conductor range for this base is 0.21 to 1.3 mm2 (24 to 16 AWG) stranded copper rated 105 C or greater, with 1.2 mm maximum insulation, with a maximum current capacity of 10 A across the base. Those figures are the base rating and not the module rating: a 16 point module on a 10 A base is still limited by the module output current per channel.
Selecting a base is a compatibility step, not a preference step. The module data sheet names the bases that are permitted for it, and a base outside that list may key differently, may not carry the required common and voltage terminals, or may not be rated for the field voltage of the module.
The D-shell bases, 1794-TB37DS and 1794-TB62DS, exist so a pre-wired cable can land on a connector instead of on screw terminals. They measure 127 by 94 by 69 mm with an expansion module installed, which is taller than the 94 by 94 by 69 mm envelope of the standard bases and has to be allowed for in the panel layout.
One point about the 24V DC digital slices that catches panel builders: the adapter supplies the field power for the modules on its own 24V output, and that output is current limited. On a 1794-ADN the supply output is 450 mA at 24V, so a slice of 16 point DC modules can exhaust the adapter before the cabinet is half filled, and a separate field supply has to be introduced rather than assumed.
Temperature class is written per module and per base, and the lower of the two governs the slice. A 70 C base carrying a 55 C module is a 55 C slice, which is why the extended temperature modules exist as a matched set rather than as an upgrade to one part of the pair.
Any FLEX I/O position is a pair on the purchase order: one base, one module. Stocking modules without bases, or bases without the matching modules, produces a slice that cannot be commissioned, and the two part numbers are never interchangeable across the 8, 16 and 32 point families.
Mounting is a DIN rail operation on both parts and the order of assembly is base first, module second: the base slides onto the rail, its backplane fingers engage the neighbouring base, and the module is then pressed onto the base and secured. Removing a module does not break the backplane, which is why a failed slice can be swapped without rewiring the row.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley Flex I/O 1794 modules category.