Allen Bradley PLC 1756-DNB / 1756DNB supplier Allen Bradley PLC 1756-DNB / 1756DNB supplier Allen Bradley PLC 1756-DNB / 1756DNB supplier Allen Bradley PLC 1756-DNB / 1756DNB supplier Allen Bradley PLC 1756-DNB / 1756DNB supplier Allen Bradley PLC 1756-DNB / 1756DNB supplier Allen Bradley PLC 1756-DNB / 1756DNB supplier

Large Image :  Allen Bradley PLC 1756-DNB / 1756DNB

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-DNB / 1756DNB

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $655.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-DNB technical data PDF download ControlLogix 1756-DNB / 1756DNB DeviceNet Scanner Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-DNB (also written 1756DNB) is the ControlLogix DeviceNet scanner: one DeviceNet port in a single-slot module, up to 64 nodes on the segment, and 125/250/500 Kbps at 500/250/100 m maximum cable length.

Published figures are 400 mA at 5.1 V DC and 0 mA at 24 V DC from the backplane, a separate 60 mA at 24 V DC on the DeviceNet side, 11…25 V DC Class 2/SELV network voltage, 3.5 W power dissipation and 11.9 BTU/hr thermal dissipation. Isolation is 50 V continuous basic between the DeviceNet network and the backplane, type tested at 853 V AC for 60 s, with no isolation between USB and the backplane. The module fits 1756-A4, A7, A10, A13 and A17 chassis and runs from the standard 1756-PA72/C, PA75/B, PB72/C, PB75/B, PC75/B or PH75/B supply, or the redundant 1756-PA75R / PB75R pair with a 1756-PSCA2 adapter (1756-TD003).

1756-DNB
DeviceNet scanner, 64 nodes, 400 mA at 5.1 V DC, 3.5 W
In stock
1756-DNBK
Conformal-coated 1756-DNB, same electrical specification
In stock
1756-CN2R
Redundant ControlNet bridge, where the segment is remote
In stock
1756-EN2T
EtherNet/IP bridge, for gateway-based DeviceNet access
In stock
1756-DHRIO
DH+ and remote I/O scanner, a different network
In stock

 Application
 DeviceNet scanner
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-DNB
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-DNB
 Mounting
 Chassis
 Number Of Channels
 1756-DNB
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-DNB DeviceNet scanner product photograph 1756-DNB, second view product photograph 1756-DNB, third view product photograph

Where the scanner sits in a typical system

A DeviceNet segment is a field network, so the scanner's job is to stand between the rack and devices that were installed years before the ControlLogix upgrade. That is the case the 1756-DNB is usually bought for: a line with DeviceNet valves, drives or photoeyes that has to be brought into a Logix controller without rewiring the segment.

One slot and 3.5 W is a small footprint for 64 nodes. The constraint is rarely rack space; it is the segment itself, where every device has an address, a baud rate and a supply of its own, and where the scanner is the only element that sees all three at once.

Where the devices are already Ethernet-capable, a gateway off an existing 1756-EN2T costs no scanner slot and no second network to maintain; where the segment is large and its devices are not replaceable, the dedicated scanner remains the cleaner engineering answer.

Commissioning in five steps

  1. Set the node address before the first power-up. The scanner and every slave on the segment share one 64-node address space, and a duplicate address shows up as a segment that will not go into run.
  2. Fix the baud rate and the cable length together: 125 Kbps allows 500 m, 250 Kbps 250 m, 500 Kbps 100 m. A segment wired for 500 Kbps that is later dropped to 125 Kbps to gain distance will not do both at once.
  3. Check the 24 V supply at the segment, not at the rack: the scanner draws no 24 V from the backplane (0 mA) and takes its DeviceNet side current from the network supply (60 mA), which has to be inside 11…25 V DC, Class 2 or SELV.
  4. Reserve one slot and confirm the 5.1 V budget: 400 mA at 5.1 V DC and 3.5 W dissipation, in any of the 1756-A4 to 1756-A17 chassis.
  5. Record the scanner's node list against the physical devices. A DeviceNet segment that scans 60 nodes but lists 61 configured devices faults on every power-up, and the fault follows the configuration file, not the wiring.

Limits: nodes, cable length, power and isolation

A scanner has no status display that can be read from a drawing; its limits are the numbers that decide whether a segment will run. Every row below is quoted from the module specification 1756-TD003.

 Indicator  State  Meaning and first action
 Data rate and cable length  125 Kbps / 500 m; 250 Kbps / 250 m; 500 Kbps / 100 m  Rate and distance are one decision, not two; the published maximum applies to the trunk length of the segment.
 Current at 5.1 V DC  400 mA  Backplane draw of the scanner itself. Sum it with the rest of the rack against the chassis 5.1 V budget.
 Current at 24 V DC  0 mA  The scanner takes no 24 V from the backplane.
 DeviceNet current at 24 V DC  60 mA  Drawn from the DeviceNet network supply, which must stay inside 11…25 V DC Class 2/SELV.
 Power dissipation  3.5 W  11.9 BTU/hr; part of the enclosure thermal load.
 Isolation  50 V continuous, basic; DeviceNet to backplane  Type tested at 853 V AC for 60 s; no isolation between USB and the backplane.
 Slot and chassis  1 slot; 1756-A4 / A7 / A10 / A13 / A17  Any chassis in the standard range; the XT chassis use the XT communication modules instead.
 Power supply  1756-PA72/C, PA75/B, PB72/C, PB75/B, PC75/B, PH75/B  Redundant option: 1756-PA75R / PB75R with the 1756-PSCA2 chassis adapter.

Node count, data rates, current draw, dissipation and isolation per Rockwell publication 1756-TD003 (1756 ControlLogix Communication Modules Specifications), Table 10 and 1756-IN050.

Replacing a 1756-DNB inside an installed panel

The 1756-DNB has no direct ControlLogix successor for every case: a DeviceNet segment either keeps a scanner in the rack or is migrated device by device to EtherNet/IP. The practical replacement question is therefore whether the segment stays.

If it stays, the scanner is replaced like for like and the configuration is restored from the project; if it migrates, the rack needs a 1756-EN2T or 1756-EN2TR and the devices need Ethernet interfaces, which is a field change, not a rack change.

The 1756-DNBK is the same module with conformal coating, for panels where condensation or corrosive atmosphere is the reason the rack is coated in the first place.

Which DeviceNet scanner to specify

  • 1756-DNB — one DeviceNet scanner port, 64 nodes, 125/250/500 Kbps, 400 mA at 5.1 V DC. The standard choice for a ControlLogix rack that has to own a DeviceNet segment.
  • 1756-DNBK — the same scanner with conformal coating, for panels where condensation or a corrosive atmosphere is already the reason the rack is coated.
  • 1756-DNB + 1756-CN2R — where the DeviceNet segment is remote and the ControlNet trunk already exists; the scanner stays local, the I/O stays on the other network.
  • 1756-EN2T + any DeviceNet gateway — where the segment is small and the rack is already Ethernet-based; a gateway costs less than a dedicated scanner slot.
  • 1756-DHRIO — not a substitute: that module scans DH+ and remote I/O, not DeviceNet.

FAQ — ControlLogix 1756-DNB / 1756DNB DeviceNet Scanner Module

How many DeviceNet nodes can the 1756-DNB handle?

Up to 64 nodes on the segment (1756-TD003).

What data rates and cable lengths are supported?

125 Kbps at 500 m maximum, 250 Kbps at 250 m, and 500 Kbps at 100 m.

How much backplane current does it draw?

400 mA at 5.1 V DC and 0 mA at 24 V DC; a separate 60 mA at 24 V DC comes from the DeviceNet network supply.

What DeviceNet supply voltage is required?

11…25 V DC, Class 2 or SELV, at the segment.

What is the power and thermal dissipation?

3.5 W and 11.9 BTU/hr maximum.

What isolation is specified?

50 V continuous basic insulation between the DeviceNet network and the backplane, type tested at 853 V AC for 60 s; there is no isolation between USB and the backplane.

Which chassis and power supplies are listed?

1756-A4, A7, A10, A13 and A17 chassis with the 1756-PA72/C, PA75/B, PB72/C, PB75/B, PC75/B or PH75/B supply, or the redundant 1756-PA75R / PB75R pair with a 1756-PSCA2 adapter.

Can it be used in an XT rack?

Not directly: the XT chassis publish their own XT module list in 1756-TD003, and the standard 1756-DNB is listed against the standard 1756-A4…A17 chassis only.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (1756 ControlLogix Communication Modules Specifications) and the manufacturer's product page for 1756-DNB. Values re-checked 16 November 2026.

Related numbers