The 1756-A7 (also written 1756A7) is the 7-slot ControlLogix chassis: capacity 7 slots, convection cooling, published minimum enclosure 50.8 x 60.9 x 20.3 cm (20 x 24 x 8 in.). It is the size most machine-level panels settle on — a controller, two network modules and four I/O modules, with one slot to spare.
It is a passive backplane with no supply inside. The modules draw from a 1756-PA75 or 1756-PB75 single supply, or from a redundant pair landing on a 1756-PSCA2 adapter in a /B (AC) or /C (DC) chassis.
The practical difference between 4 and 7 slots is 10.1 cm of panel width and three modules of capacity, for the same 50.8 cm enclosure height. That is why a 7-slot rack is usually the correct choice when the I/O count is known but not final.
Published record: UPC 612598129317, active lifecycle, estimated lead time 10 days, country of origin multiple, one year warranty, publications 1756-SG001 and the chassis installation instructions.
1756-A4 |
4 slots, minimum enclosure 50.8 x 50.8 x 20.3 cm, UPC 612598129300 |
In stock |
1756-A7 |
7 slots, minimum enclosure 50.8 x 60.9 x 20.3 cm, UPC 612598129317 |
In stock |
1756-A10 |
10 slots, minimum enclosure 50.8 x 76.2 x 20.3 cm, UPC 612598129270 |
In stock |
1756-A13 |
13 slots, minimum enclosure 60.9 x 76.2 x 20.3 cm, UPC 612598129287 |
In stock |
1756-A17 |
17 slots, minimum enclosure 76.2 x 91.4 x 20.3 cm, UPC 612598129294 |
In stock |
Application |
Chassis / backplane |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-A7 |
Communication |
— |
Display |
— |
Enclosure |
Open chassis, convection cooled |
Interface |
Backplane |
Mounting |
Panel, bracket supplied |
Number Of Channels |
— |
Standard |
CE, UL, cUL |
Sub Brand |
ControlLogix |
Type |
Chassis |
UNSPSC |
— |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (chassis installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Seven slots is the natural size for a machine cell: one controller, two network modules (often EtherNet/IP plus a device network), and four I/O modules covering the field devices. It leaves one slot for a future function rather than forcing a second chassis.
It also gives the cleanest thermal result of the family: 50.8 cm height with convection cooling, enough volume for the modules without a fan and its filter maintenance.
In a redundant design, the 7-slot /B or /C rack is a common choice for a cell that must ride through a supply failure — the pair, the adapter and two cables occupy the enclosure beside the rack, not inside it.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | Slot budget with comms | A redundant or dual-network design can consume two or three slots before any I/O. Count those first, then the I/O. |
| Check 3 | Convection clearance | No fan means the enclosure has to breathe. The published 50.8 x 60.9 x 20.3 cm is a volume minimum with the convection path open. |
| Check 4 | Series and supply pairing | /B with the AC redundant pair, /C with the DC pair, standard chassis with a single supply — 1756-IN620 is the table to check. |
| Check 5 | Panel width | 60.9 cm minimum width. A panel sized for a 4-slot rack will not take a 7-slot one without re-layout. |
Slot and supply compatibility per Rockwell publication 1756-IN620 (ControlLogix Redundant Power Supply installation instructions) and 1756-UM001 (ControlLogix system user manual, chassis installation) and 1756-IN050.
Down one step is 1756-A4 (4 slots, 50.8 x 50.8 cm); up one step is 1756-A10 (10 slots, 50.8 x 76.2 cm). The height stays the same across all three, so the panel height decision does not change.
Because the rack is a fixed backplane, changing slot count later means a new chassis and a re-terminated panel. Choose the size from the I/O schedule plus spare capacity.
The supply, adapter and cables are shared across the family, so a rack replacement keeps the power hardware.
What is the 1756-A7?
A 7-slot ControlLogix chassis, convection cooled, published minimum enclosure 50.8 x 60.9 x 20.3 cm, UPC 612598129317.
How many modules fit?
Seven. The power supply sits in the leftmost position and is not counted as a slot.
Is a power supply included?
No — order 1756-PA75, 1756-PB75, or a redundant pair with 1756-PSCA2 on a /B or /C chassis.
Which series do I need for redundancy?
/B for the AC redundant pair, /C for the DC pair, per the compatibility table in 1756-IN620.
How much enclosure space?
Minimum 50.8 x 60.9 x 20.3 cm (20 x 24 x 8 in.), with the convection path open.
Does it need a fan?
No. The chassis is convection cooled, which is one less filter and one less failure mode in a dirty plant.
What is the lead time and origin?
Estimated lead time 10 days as published; country of origin depends on manufacturing location and is marked on the packaging.
What drawings are published?
2-dimensional drawings and a 3-D STEP model for the panel layout.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-A7. Values re-checked 15 November 2026.