The 1756-PA72 (also written 1756PA72) is the standard ControlLogix AC power supply: 85…265 V AC input at 47…63 Hz, 75 W of conditioned output into the chassis backplane, with 10 A available at 5.1 V DC and 2.8 A at 24 V DC.
It mounts on the left end of a 1756 chassis and feeds the backplane directly — there is no separate power bus, no external 5 V supply and no wiring between modules. The 5.1 V, 3.3 V, 1.2 V and 24 V rails are generated inside the supply and distributed by the chassis.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Chassis power supply, AC input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-PA72 |
Type |
ControlLogix standard power supply |
Sub Brand |
ControlLogix |
Mounting |
Left end of 1756 chassis |
Input Voltage |
85…265 V AC, 47…63 Hz |
Input Power |
100 VA / 100 W maximum |
Output Power |
75 W at 0…60 °C |
Current At 5.1 V |
10 A |
Current At 24 V |
2.8 A |
Current At 3.3 V |
4 A |
Current At 1.2 V |
1.5 A |
Inrush Current |
20 A maximum |
Hold-Up |
5 cycles at 85 V AC; 6 cycles at 120/200/240 V AC |
Isolation |
250 V reinforced, tested 3500 V DC for 60 s |
Chassis |
1756-A4, A7, A10, A13, A17; series A, B, C |
Wire Size |
2.5 mm² (14 AWG), 90 °C minimum |
Terminal Torque |
0.565 N·m (5 lb·in) |
Weight |
0.95 kg (2.10 lb) |
Dimensions |
14.0 x 11.2 x 14.5 cm |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 75 W output rating is the number that governs chassis sizing. It is the sum of the 5.1 V, 24 V, 3.3 V and 1.2 V rails, not a 5.1 V figure alone, so a chassis with many 24 V output modules can exhaust the supply on the 24 V rail while the 5.1 V current is still below its 10 A limit.
The per-rail figures are published separately: 1.5 A at 1.2 V, 4 A at 3.3 V, 10 A at 5.1 V and 2.8 A at 24 V. In practice the 5.1 V rail is the one that limits module count, because most ControlLogix I/O draws its backplane current there, and the 24 V rail is the one that fails first when a panel adds field-powered devices.
Hold-up is specified in cycles at stated input and load, not in milliseconds: five cycles at 85 V AC, six cycles at 120, 200 and 240 V AC. A chassis that must ride through a transfer to generator needs the figure at the actual site voltage, and 85 V AC on a loaded transformer is a realistic worst case.
Isolation is 250 V continuous, reinforced, from power input to backplane, type tested at 3500 V DC for 60 seconds. That is what allows the supply to be fed from a distribution circuit that is not bonded to the backplane reference.
Inrush is 20 A maximum. Where several chassis energise from one contactor, the published inrush is the number to give the breaker supplier, not the 75 W steady-state load.
Chassis compatibility is a series question rather than a slot question: the PA72 fits 1756-A4, A7, A10, A13 and A17 chassis in series A, B or C, and mounts at the left end. A redundant arrangement is a different product — two 1756-PA75R supplies with a 1756-PSCA2 adapter, supplied as kit 1756-PAR2.
A power supply carries no diagnostic display of its own; the useful evidence is the input voltage under load, the total chassis wattage and the published hold-up at the site voltage.
| Indicator | State | Meaning and first action |
| Chassis browns out on a load step | Voltage dip | The 75 W output budget is shared by all rails; an added 24 V load can exhaust it before the 5.1 V current limit is reached. |
| Supply restarts on a short | Inrush | Inrush is 20 A on the AC unit and 30 A on the DC unit; confirm the upstream breaker tolerates repeated energisation. |
| Hold-up shorter than expected | — | Hold-up is published in cycles at a stated input and load, not as a fixed millisecond figure. |
Input, output and hold-up figures per Rockwell publication 1756-TD005-EN-E and 1756-IN050.
Measure the input at the terminals under load before replacing a supply that appears dead. A 240 V circuit reading 208 V is still inside the 85…265 V window, while a sagging 120 V circuit on a long feed may not be.
Check the chassis load budget. A supply that trips after a module was added is usually over the 75 W total rather than faulty, and a replacement unit behaves the same way.
Keep the input wiring gauge and torque as published — 2.5 mm² (14 AWG) at 90 °C minimum, 0.565 N·m (5 lb·in) — because a loose input terminal behaves like a failing supply under load.
What is the 1756-PA72?
A standard ControlLogix AC power supply rated 75 W output, mounted on the left end of the chassis.
What input voltage does it accept?
85…265 V AC at 47…63 Hz, nominal 120/240 V AC.
What current is available at 5.1 V DC?
10 A.
What current is available at 24 V DC?
2.8 A.
What is the total output power?
75 W at 0…60 °C, shared across the 5.1 V, 24 V, 3.3 V and 1.2 V rails.
What is the hold-up time?
Five cycles at 85 V AC and six cycles at 120, 200 or 240 V AC, 50/60 Hz.
Which chassis does it fit?
1756-A4, A7, A10, A13 and A17 chassis, series A, B or C.
What is the isolation rating?
250 V continuous, reinforced, power input to backplane, type tested at 3500 V DC for 60 s.
Data sources. Technical values on this page come from Rockwell publications 1756-TD005 (ControlLogix Power Supplies Specifications) - input, output, hold-up, isolation and environmental data for 1756-PA72; 1756-SG001 (ControlLogix System Selection Guide) - chassis and supply selection and the manufacturer's product page for 1756-PA72. Values re-checked 16 November 2026.