Allen Bradley PLC 1756-IT6I2 / 1756IT6I2

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IT6I2 / 1756IT6I2

China Allen Bradley PLC 1756-IT6I2 / 1756IT6I2 supplier
Allen Bradley PLC 1756-IT6I2 / 1756IT6I2 supplier Allen Bradley PLC 1756-IT6I2 / 1756IT6I2 supplier Allen Bradley PLC 1756-IT6I2 / 1756IT6I2 supplier Allen Bradley PLC 1756-IT6I2 / 1756IT6I2 supplier Allen Bradley PLC 1756-IT6I2 / 1756IT6I2 supplier Allen Bradley PLC 1756-IT6I2 / 1756IT6I2 supplier

Large Image :  Allen Bradley PLC 1756-IT6I2 / 1756IT6I2

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IT6I2 / 1756IT6I2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1168.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 4 PCS
Detailed Product Description

1756-IT6I2 technical data PDF download 1756-IT6I2 ControlLogix 6 Point Enhanced Thermocouple | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IT6I2 (also written 1756IT6I2) is the enhanced thermocouple input of the isolated 6-channel generation: six individually isolated channels with two cold junction sensors, 16-bit resolution at 1.4 µV per bit on the -12...78 mV range and 0.7 µV per bit on the high-resolution -12...30 mV range, backplane load 200 mA at 5.1 V DC and 150 mA at 24 V DC, 4.6 W (1756-TD002).

Two cold junction sensors is the difference a commissioning engineer notices. The module ships with two 94286501 sensors (replacement RP-94286501), one for each terminal area, so six channels across a 20-pin housing do not depend on a single junction measurement at one end of the block.

The published performance is the same family standard: input impedance above 10 MΩ, open circuit detected as positive full scale within 2 s, overvoltage protection 120 V AC/DC, 60 dB normal mode rejection at 60 Hz, settling under 80 ms to 5 % of full scale, module error 0.15 % of range, and calibration interval 12 months.

Isolation is 250 V continuous basic between channels and to the backplane, and the module takes 1756-TBNH only — the spring-clamp TBSH is not listed for this number. Technical data 1756-TD002, user manual 1756-UM009.

1756-IF4FXOF2F
4 high-speed differential inputs + 2 outputs, 375 mA, reinforced isolation
In stock
1756-IF6CIS
6 isolated current inputs with sourcing 24 V DC loop supply
In stock
1756-IF6I
6 isolated inputs, 16-bit, 250 mA, channel-to-channel basic isolation
In stock
1756-IF8
8 single-ended / 4 differential inputs, 200 mA, 250 V basic to backplane
In stock
1756-IF8H
8 differential HART current inputs, A and B series
In stock
1756-IF16
16 single-ended / 8 differential inputs, 200 mA, 15 Hz bandwidth
In stock
1756-IF16H
16 differential HART current inputs, A and B series
In stock
1756-IRT8I
8 isolated RTD and thermocouple inputs, 24-bit, 1756-CJC required
In stock
1756-IR6I
6 isolated RTD inputs, 20-pin block, discontinued 2017
In stock
1756-IT6I
6 thermocouple inputs, two mV ranges, one CJC sensor
In stock
1756-IT6I2
6 isolated thermocouple inputs, 16-bit, two CJC sensors
In stock

 Application
 Analog input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IT6I2
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 6
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Analog Input Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN063 (analog I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IT6I2 thermocouple input product photograph 1756-IT6I2 terminal side product photograph 1756-IT6I2 module view product photograph

Where the module sits in a typical system

The IT6I2 is the 6-channel thermocouple module for panels that need per-channel isolation with better accuracy than the original IT6I: heat-treat furnaces, kilns and ovens where six zones are measured against separate references.

Its two cold junction sensors make it the better choice of the two legacy numbers for a module installed at the end of a long terminal block, where the junction temperature varies across the housing.

For new installations the 16-channel IT16 or the 8-channel IRT8I is the current answer; the IT6I2 remains the drop-in for existing drawings that specify six channels on a TBNH.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's analogue I/O instructions include keying as a step, and a block keyed for a different module will not seat.
  2. Wire signal conductors to category 2 and keep them out of the same duct as the 480 V motor feeders. The analogue front end is the part of the rack that reads induced noise as measurement.
  3. Terminate the cable shield at the panel earth, not at the module terminals. A shield carried onto the RTB becomes an antenna for the next drive cabinet.
  4. Set the notch filter to the local mains frequency — 50 Hz or 60 Hz — in the Logix Designer project. The published settling time, scan time and noise rejection figures are all quoted at a selected notch frequency.
  5. Check the field range against the module's real range, not the sensor's nominal one. An IF6I accepts 0...21 mA with overrange indication, which is wider than a 4...20 mA transmitter needs and narrower than a 0...25 mA device supplies.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  TBNH only  The terminal block is restricted to 1756-TBNH. A TBSH spring-clamp housing is not published for this module.
 Check 3  Range choice changes resolution  0.7 µV per bit on the 30 mV range against 1.4 µV per bit on 78 mV. The narrower range halves the step but truncates the span for most types.
 Check 4  0.15 % module error  Tighter than the 0.54 % of the non-enhanced 6-channel family, and the reason this number stayed in service longer.
 Check 5  Basic isolation  250 V basic, channel-to-channel and to the backplane. Where a reinforced barrier is required, the 1756-IRT8I or 1756-IT16 is the module.

Specifications per Rockwell publication 1756-TD002 (ControlLogix I/O Modules Specifications); module behaviour per 1756-UM009 and 1756-IN050.

Replacing a 1756-IF6I of an earlier generation

For a wider count, 1756-IT16 provides 16 thermocouple channels; 1756-IRT8I provides 8 channels accepting thermocouples and RTDs at 24-bit resolution.

The original 6-channel number is 1756-IT6I, with one cold junction sensor and the wider module error.

For RTDs, 1756-IR12 at 12 channels and 24-bit resolution, or the legacy 1756-IR6I.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IF4FXOF2F — 4 high-speed differential inputs plus 2 high-speed outputs in one slot, 375 mA at 5.1 V DC, 250 V reinforced isolation.
  • 1756-IF8 — 8 single-ended (or 4 differential) inputs, 200 mA at 5.1 V DC, 250 V basic isolation to the backplane.
  • 1756-IF16 — 16 single-ended inputs, 200 mA at 5.1 V DC, same ranges as the IF8 with 15 Hz channel bandwidth.
  • 1756-IF6I — 6 individually isolated inputs, 250 mA at 5.1 V DC, 16-bit resolution, channel-to-channel isolation.
  • 1756-IF6CIS — 6 isolated current inputs with per-channel 24 V DC loop sourcing for 2-wire transmitters.
  • 1756-IF8H / 1756-IF16H — the HART variants, 8 or 16 differential current inputs, one modem per module (A series) or per channel (B series).
  • 1756-IRT8I / 1756-IR12 — RTD and thermocouple measurement, 250 V reinforced isolation, 24-bit resolution.
  • 1756-TBNH / 1756-TBCH / 1756-TBSH / 1756-TBS6H — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IT6I2 ControlLogix 6 Point Enhanced Thermocouple | Rockwell

What is the 1756-IT6I2?

A 6-channel enhanced thermocouple input module with 16-bit resolution and two cold junction sensors.

What is the backplane current?

200 mA at 5.1 V DC and 150 mA at 24 V DC, 4.6 W total backplane power (1756-TD002).

How many cold junction sensors does it use?

Two — 94286501 sensors are shipped, replacements ordered as RP-94286501.

What resolution does each range give?

1.4 µV per bit on -12...78 mV, 0.7 µV per bit on the high-resolution -12...30 mV range.

Which terminal block fits?

1756-TBNH only; the spring-clamp TBSH is not published for this module.

What isolation does it provide?

250 V continuous basic insulation, channel-to-channel and to the backplane.

What is the module error?

0.15 % of range over the temperature range, with a 12-month calibration interval.

What documents cover it?

1756-TD002 for technical data and 1756-UM009 for the user manual.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IT6I2. Values re-checked 15 November 2026.