Product Details:
Payment & Shipping Terms:
|
The 1756-IT6I2 (also written 1756IT6I2) is the enhanced thermocouple input of the isolated 6-channel generation: six individually isolated channels with two cold junction sensors, 16-bit resolution at 1.4 µV per bit on the -12...78 mV range and 0.7 µV per bit on the high-resolution -12...30 mV range, backplane load 200 mA at 5.1 V DC and 150 mA at 24 V DC, 4.6 W (1756-TD002).
Two cold junction sensors is the difference a commissioning engineer notices. The module ships with two 94286501 sensors (replacement RP-94286501), one for each terminal area, so six channels across a 20-pin housing do not depend on a single junction measurement at one end of the block.
The published performance is the same family standard: input impedance above 10 MΩ, open circuit detected as positive full scale within 2 s, overvoltage protection 120 V AC/DC, 60 dB normal mode rejection at 60 Hz, settling under 80 ms to 5 % of full scale, module error 0.15 % of range, and calibration interval 12 months.
Isolation is 250 V continuous basic between channels and to the backplane, and the module takes 1756-TBNH only — the spring-clamp TBSH is not listed for this number. Technical data 1756-TD002, user manual 1756-UM009.
1756-IF4FXOF2F |
4 high-speed differential inputs + 2 outputs, 375 mA, reinforced isolation |
In stock |
1756-IF6CIS |
6 isolated current inputs with sourcing 24 V DC loop supply |
In stock |
1756-IF6I |
6 isolated inputs, 16-bit, 250 mA, channel-to-channel basic isolation |
In stock |
1756-IF8 |
8 single-ended / 4 differential inputs, 200 mA, 250 V basic to backplane |
In stock |
1756-IF8H |
8 differential HART current inputs, A and B series |
In stock |
1756-IF16 |
16 single-ended / 8 differential inputs, 200 mA, 15 Hz bandwidth |
In stock |
1756-IF16H |
16 differential HART current inputs, A and B series |
In stock |
1756-IRT8I |
8 isolated RTD and thermocouple inputs, 24-bit, 1756-CJC required |
In stock |
1756-IR6I |
6 isolated RTD inputs, 20-pin block, discontinued 2017 |
In stock |
1756-IT6I |
6 thermocouple inputs, two mV ranges, one CJC sensor |
In stock |
1756-IT6I2 |
6 isolated thermocouple inputs, 16-bit, two CJC sensors |
In stock |
Application |
Analog input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-IT6I2 |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
6 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Analog Input Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN063 (analog I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The IT6I2 is the 6-channel thermocouple module for panels that need per-channel isolation with better accuracy than the original IT6I: heat-treat furnaces, kilns and ovens where six zones are measured against separate references.
Its two cold junction sensors make it the better choice of the two legacy numbers for a module installed at the end of a long terminal block, where the junction temperature varies across the housing.
For new installations the 16-channel IT16 or the 8-channel IRT8I is the current answer; the IT6I2 remains the drop-in for existing drawings that specify six channels on a TBNH.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | TBNH only | The terminal block is restricted to 1756-TBNH. A TBSH spring-clamp housing is not published for this module. |
| Check 3 | Range choice changes resolution | 0.7 µV per bit on the 30 mV range against 1.4 µV per bit on 78 mV. The narrower range halves the step but truncates the span for most types. |
| Check 4 | 0.15 % module error | Tighter than the 0.54 % of the non-enhanced 6-channel family, and the reason this number stayed in service longer. |
| Check 5 | Basic isolation | 250 V basic, channel-to-channel and to the backplane. Where a reinforced barrier is required, the 1756-IRT8I or 1756-IT16 is the module. |
Specifications per Rockwell publication 1756-TD002 (ControlLogix I/O Modules Specifications); module behaviour per 1756-UM009 and 1756-IN050.
For a wider count, 1756-IT16 provides 16 thermocouple channels; 1756-IRT8I provides 8 channels accepting thermocouples and RTDs at 24-bit resolution.
The original 6-channel number is 1756-IT6I, with one cold junction sensor and the wider module error.
For RTDs, 1756-IR12 at 12 channels and 24-bit resolution, or the legacy 1756-IR6I.
What is the 1756-IT6I2?
A 6-channel enhanced thermocouple input module with 16-bit resolution and two cold junction sensors.
What is the backplane current?
200 mA at 5.1 V DC and 150 mA at 24 V DC, 4.6 W total backplane power (1756-TD002).
How many cold junction sensors does it use?
Two — 94286501 sensors are shipped, replacements ordered as RP-94286501.
What resolution does each range give?
1.4 µV per bit on -12...78 mV, 0.7 µV per bit on the high-resolution -12...30 mV range.
Which terminal block fits?
1756-TBNH only; the spring-clamp TBSH is not published for this module.
What isolation does it provide?
250 V continuous basic insulation, channel-to-channel and to the backplane.
What is the module error?
0.15 % of range over the temperature range, with a 12-month calibration interval.
What documents cover it?
1756-TD002 for technical data and 1756-UM009 for the user manual.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IT6I2. Values re-checked 15 November 2026.