logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-BA2 / 1756BA2

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-BA2 / 1756BA2

China Allen Bradley PLC 1756-BA2 / 1756BA2 supplier
Allen Bradley PLC 1756-BA2 / 1756BA2 supplier Allen Bradley PLC 1756-BA2 / 1756BA2 supplier Allen Bradley PLC 1756-BA2 / 1756BA2 supplier Allen Bradley PLC 1756-BA2 / 1756BA2 supplier Allen Bradley PLC 1756-BA2 / 1756BA2 supplier Allen Bradley PLC 1756-BA2 / 1756BA2 supplier

Large Image :  Allen Bradley PLC 1756-BA2 / 1756BA2

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-BA2 / 1756BA2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $59.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 20 PCS
Detailed Product Description

1756-BA2 technical data PDF download 1756-BA2 ControlLogix L6X Series B Battery Assembly | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-BA2 (also written 1756BA2) is the lithium battery assembly Rockwell titles ControlLogix L6X Ser B ONLY Battery Assy — a replacement battery backup for Series B 1756-L6x controllers. The 'Ser B ONLY' wording is the whole specification in one line: it is the battery for one controller series, not a universal ControlLogix battery.

Its lifecycle status is published as End of Life: Rockwell announces that as of 31 December 2027 the assembly will be discontinued and no longer available for sale, with no planned RA replacement. That date is the single most important fact about this part, because it decides whether a spare-battery policy is still a maintenance plan or has become a migration plan.

Published attributes: Series A, UPC 612598322152, function replacement battery backup, parent figure 'for use with ControlLogix 5560', temperature rating 0...60 °C (32...140 °F), country of origin multiple, one year standard warranty, cutsheet 1756-TD001 and selection guide 1756-SG001.

What the battery does is stated by Rockwell as battery backup: it holds the controller while the rack is without power. What it does not do is extend the controller's life — an assembly that is end of life is a support horizon for the installed base, not a design option for a new machine.

1756-BA2
Lithium battery assembly, Series B 1756-L6x only, end of life 2027-12-31, UPC 612598322152
Limited stock
1756-BATA
Replacement battery assembly for 1756-BATM, end of life 2027-12-31, UPC 612598284757
Limited stock
1756-BATM
Battery module, 20 mA max at 3.6 V DC, discontinued 2017-07-18, UPC 612598284764
Limited stock

 Application
 Controller battery backup
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-BA2
 Communication
 —
 Display
 —
 Enclosure
 —
 Interface
 Controller battery connector
 Mounting
 Inside controller / module
 Number Of Channels
 —
 Standard
 CE, UL
 Sub Brand
 ControlLogix
 Type
 Battery
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN576 (battery module installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-BA2 battery assembly product photograph 1756-BA2 pack detail product photograph 1756-BA2 battery set product photograph

Where the module sits in a typical system

The assembly is a maintenance item, not a design item. Its value in a plant is measured by how long the control system can keep its backup while a replacement is found — and that window closes when the 2027 discontinued date passes.

For an installed base still running Series B 1756-L6x controllers, the sensible move is to size the last buy against the remaining service life of those controllers, not against the warranty period of the machine.

Because the assembly is small and cheap compared with a controller, holding a spare per rack is the cheapest insurance available against a controller losing its backup during a long power outage.

Commissioning in five steps

  1. Read the series letter on the controller label first. The 1756-BA2 title states 'L6X Ser B ONLY', so a Series A controller is a different battery — the wrong assembly either will not fit or will not be recognised.
  2. Replace the battery with the chassis de-energised and the controller powered down by the documented procedure, so the controller is not left relying on a battery that has just been removed.
  3. Dispose of the removed lithium assembly through the battery waste route. It is a lithium cell, not general electronic waste.
  4. Record the replacement date on the panel schedule. The assemblies carry a shelf life, so a spare kept in a stores bin for years is not the same as a spare bought for this outage.
  5. Because all three catalogue numbers are end-of-life or discontinued, check the current stock position before promising a delivery date to a customer.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  End of life, not end of stock  Rockwell's discontinued date is 31 December 2027 with no planned replacement. Orders are still possible until that date, but availability tightens and price moves — plan the last buy deliberately.
 Check 3  One assembly per controller  The battery backs up one controller. A rack with two controllers needs two assemblies, and a spare in stores is a third.
 Check 4  Temperature rating  0...60 °C (32...140 °F) as published. A battery in a cabinet that runs hot loses capacity sooner than the rating suggests.
 Check 5  Date on the assembly  Batteries have a shelf life. A spare bought for this outage and a spare from the back of the stores bin are different risks; record the replacement date on the panel schedule.

Lifecycle dates and attributes per the Rockwell product record for this catalogue number; battery data per 1756-TD001 / 1756-TD002 and installation instructions 1756-IN576 and 1756-IN050.

Replacing a 1756-BA2

There is no planned Rockwell replacement for this assembly. Any migration therefore goes through the controller: a newer controller generation uses a different backup arrangement entirely, which is a project, not a parts swap.

Do not substitute a battery from another controller family. The 'L6X Ser B ONLY' wording exists precisely because the assembly is series-specific.

If the controller itself is being replaced, the battery decision travels with it — check the selection guide 1756-SG001 for the backup arrangement of the target controller.

Which ControlLogix EtherNet/IP module to specify

  • 1756-BA2 — lithium battery assembly titled 'ControlLogix L6X Ser B ONLY'; fits Series B 1756-L6x controllers, end of life with a 31 December 2027 discontinued date.
  • 1756-BATA — replacement battery assembly for the 1756-BATM module; same end-of-life date, no planned replacement.
  • 1756-BATM — ControlLogix battery module, discontinued 18 July 2017, output 20 mA max at 3.6 V DC, installation instructions 1756-IN576.
  • 1756-TD001 — controller technical data, the cutsheet for the L6x battery assembly.
  • 1756-TD002 — battery cutsheet listed against the 1756-BATA replacement assembly.
  • 1756-SG001 — selection guide; use it to confirm which battery a given controller series takes.

FAQ — 1756-BA2 ControlLogix L6X Series B Battery Assembly | Rockwell

What controllers does the 1756-BA2 fit?

Series B 1756-L6x controllers only — the product title states 'ControlLogix L6X Ser B ONLY Battery Assy'.

Is the 1756-BA2 still available?

It is published as End of Life, with a discontinued date of 31 December 2027 and no planned Rockwell replacement. Availability until that date depends on stock in the channel.

What is it for?

Battery backup of the controller while the rack is without power — Rockwell lists its function as replacement battery backup.

What is the temperature rating?

0...60 °C (32...140 °F) as published.

Does it fit a Series A controller?

No. The assembly is specific to Series B; a Series A controller takes its own battery, and the selection guide 1756-SG001 is the reference.

How many do I need?

One per controller, plus whatever spares policy the plant keeps. A two-controller rack needs two assemblies.

What is the UPC?

612598322152, country of origin multiple, one year standard warranty.

What replaces it after 2027?

Nothing at assembly level. The controller generation is the migration path, which is why the last-buy quantity should be sized to the remaining service life of the installed controllers.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-BA2. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)