Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 1784-SD1, the one gigabyte Secure Digital card that ships with CompactLogix 5370 controllers. The capacity, shipment state and power behaviour below are published facts about the card; the contents of any particular card are not a specification, and are not asserted here.
| Specification | Value |
|---|---|
| Catalog number | 1784-SD1 |
| Product type | Secure Digital (SD) card for nonvolatile memory |
| Capacity | 1 GB of available memory |
| Shipment | Shipped with CompactLogix 5370 controllers, installed in the controller |
| Use | Nonvolatile storage of the controller project, loaded and saved through the programming software |
| Power behaviour | System energy maintains controller power long enough to store the program to internal nonvolatile memory, but not enough to write the external SD card |
This catalog number is a memory card, and the published data about it is mostly about where it comes from rather than what it holds. The card is published as 1 GB of available memory, and it is shipped with the CompactLogix 5370 controllers already installed in the controller, which makes it the card that most plants already own without knowing its catalog number.
The card's function is published as nonvolatile memory for the controller, written and read through the programming software. That distinction matters: the card is not a backup that happens by itself, it is a store that a person or a routine writes to, and a card that has never been written is a card with nothing on it.
The published power behaviour is the most important sentence about this part: system energy maintains controller power long enough to store the program to internal nonvolatile memory, but not enough to write the external SD card. A power loss therefore leaves the internal store current and the card as it was, which is a very different guarantee from the one people assume when they hear the word nonvolatile.
A 1 GB card is published as available memory, and the useful size comparison is the controller's own program, not a desktop file. A 5370 program with a few thousand tags and a handful of routines occupies a small fraction of a gigabyte, so the card's capacity is not the constraint; the write procedure and the version on it are.
Manual save and load are published as operations performed through the programming software, with the option to configure the controller to load from the card at powerup. That configuration is a project decision with a maintenance consequence: a controller set to load from the card will revert to the card's contents after a power cycle, which is wanted in some plants and disastrous in others.
The card being shipped installed means a replacement controller arrives with a card that carries no project. A maintenance team that swaps a controller and expects the program to follow it is relying on a procedure, not on the card, and the published shipment fact is why that procedure has to exist.
Because the card is an SD card in a socket, its physical security is published by its form rather than by a rule. A card can be removed, copied and carried, which is convenient for a backup and awkward for a change control policy, and a plant's answer to that is a procedure rather than a catalog number.
The published note that the 1768 and 5370 controllers do not require a battery is related to the same energy storage that makes the internal save work. A controller without a battery is a controller whose retention depends on a capacitor-like store, and the published limits of that store are exactly what the SD card write does not fit inside.
A card that is written once at commissioning and never again is a card that records an old project. The most common field condition is a card containing the program as it was at the FAT date, while the controller has run three revisions since, and the published load-from-card option is what turns that stale record into a running controller.
A 1 GB card at this price is a consumable, and treating it as a spare rather than as a component is the correct posture. The published capacity and shipment facts are enough to identify the part; the procedure around it is what prevents the incident.
The card is published as shipped in the controller, which makes it part of the delivered configuration rather than an accessory. A machine builder who strips the card before shipping a panel ships a controller without its standard store, and a plant that receives it has to supply the difference without anyone recording why.
A 1 GB card is published as available memory, and a controller project's own size is the only useful denominator. A plant that has never measured its program size does not know whether the card is nearly full, and the published measurement path is the programming software rather than the label on the card.
A spare card is the cheapest item in a controller replacement and the only one whose value depends entirely on what was written to it. A spare with a current project is a recovery; a spare with nothing is a blank that has to be filled from a laptop, which is a different kind of outage.
The other 1784 interface cards, memory cards and legacy interface products in this range are collected in the 1784 interface cards and memory products category. This card can be checked against the shop listing at 1784-SD1, and the other capacity is listed at 1784-SD2.
The table puts the eight 1784 records on this site side by side on the three fields that make them comparable - what the page calls the part, how it attaches to the host, and which network it reaches - together with the lifecycle sentence each record prints. Half of these parts are cables or memory and print no network interface at all.
| Catalog number | What the page calls it | Host interface as printed | Network as printed | Lifecycle as printed |
| 1784-PCC1 | PCMCIA cable to ControlNet | PCMCIA Type II | ControlNet | Active Mature |
| 1784-PCD1 | PCMCIA cable to DeviceNet | PCMCIA Type II | DeviceNet | Active |
| 1784-PKTCS | PCI scanner card | PCI | ControlNet | Discontinued May 8, 2019 |
| 1784-PKTXD | PCI dual-channel card | PCI | DH+ / remote I/O / DH-485 | Discontinued March 31, 2022 |
| 1784-SD1 | SD memory card, 1 GB | not applicable | not applicable | not printed |
| 1784-SD2 | SD memory card, 2 GB | not applicable | not applicable | not printed |
| 1784-U2CN | USB interface to ControlNet | USB | ControlNet | Discontinued April 01, 2024 |
| 1784-U2DN | USB interface to DeviceNet | USB | DeviceNet | Active |
Where this record sits: the page prints it as "Secure Digital (SD) card for nonvolatile memory". In the eight-record group the host side is not applicable and the network side is not applicable, and the lifecycle row reads "not printed on this record". Across the group 3 records stand at Active or Active Mature, 3 print a discontinuation, and the two SD cards print no lifecycle row at all - so the family is a set of accessories of very different age rather than a single product line.
Both records in this group that attach a PC to ControlNet - the PCI scanner card and the USB interface - print a discontinuation with no planned replacement, while the two DeviceNet equivalents print Active. That is the single most useful line the group can give a project: a ControlNet segment that needs a PC connection today has to be planned around existing stock, not around a current catalogue number.
What these eight records do not carry: no current draw on any interface, no operating system or driver requirement, no cable pinout beyond a verbal description of each end, no software version and no supported-host list. The lifecycle and network rows are therefore the only planning data on the pages, and a compatibility check has to be done against the installation instruction each record cites.
The power-behaviour sentence printed here is the one worth keeping: system energy holds the controller up long enough to store the program to internal nonvolatile memory, but not long enough to write the external SD card. A power loss during a save therefore leaves the card untouched rather than half-written.
Source: the field tables printed on the eight 1784 records on this site - catalog number, product type, host interface, network, lifecycle, replacement, country of origin and the installation instruction each cites - with the control-network figures (99 nodes, 500 m, IP20) quoted from the record that prints them. Nothing in this table is inferred from a catalog number.