The 1756-PA75 (also written 1756PA75) is the larger standard AC power supply for the 1756 chassis: 85…265 V AC input, 75 W output, and 13 A at 5.1 V DC instead of the 10 A of the PA72.
Both units carry the same 75 W ceiling and the same physical size; the difference is how much of that budget can be drawn on the 5.1 V rail, which is where dense chassis fail first.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Chassis power supply, AC input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-PA75 |
Type |
ControlLogix standard power supply |
Sub Brand |
ControlLogix |
Mounting |
Left end of 1756 chassis |
Input Voltage |
85…265 V AC, 47…63 Hz |
Input Power |
100 VA / 100 W maximum |
Output Power |
75 W at 0…60 °C |
Current At 5.1 V |
13 A |
Current At 24 V |
2.8 A |
Current At 3.3 V |
4 A |
Current At 1.2 V |
1.5 A |
Inrush Current |
20 A maximum |
Hold-Up |
2 cycles at 85 V; 6 cycles at 120 V; 20 cycles at 220 V, 60 Hz |
Isolation |
250 V reinforced, tested 3500 V DC for 60 s |
Chassis |
1756-A4, A7, A10, A13, A17; series B, C |
Wire Size |
2.5 mm² (14 AWG), 90 °C minimum |
Terminal Torque |
0.565 N·m (5 lb·in) |
Weight |
0.95 kg (2.10 lb) |
Dimensions |
14.0 x 11.2 x 14.5 cm |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The PA75 exists because ControlLogix I/O backplane current is drawn mostly at 5.1 V. A full chassis of analog and communication modules can sit under 75 W total while pulling more than 10 A at 5.1 V, and that is exactly the case the 13 A rating covers.
The trade is not free: 75 W remains the sum of the 5.1 V, 24 V, 3.3 V and 1.2 V rails at 0…60 °C. If the chassis needs 13 A at 5.1 V it has almost no room left for 24 V loads, so modules that pull 24 V backplane current have to be counted against the same budget.
Hold-up behaves differently at the low end of the input window: two cycles at 85 V AC, six cycles at 120 V AC and twenty cycles at 220 V AC, all at 60 Hz. The spread is the reason a 220 V panel can ride through a short transfer that a 110 V panel cannot, even with the same supply.
Isolation is 250 V continuous, reinforced, type tested at 3500 V DC for 60 seconds, and the input is wired with 2.5 mm² (14 AWG) at 90 °C minimum into terminals torqued to 0.565 N·m.
Chassis compatibility for the PA75 is series B or C only — the earlier series A chassis takes the PA72. That single letter in the chassis part number catches more retrofits than any other supply detail.
For redundancy the PA75 is the building block: two 1756-PA75R units with their CPR2 cables and a PSCA2 chassis adapter, sold as kit 1756-PAR2, provide a second input path without an external diode module.
A power supply carries no diagnostic display of its own; the useful evidence is the input voltage under load, the total chassis wattage and the published hold-up at the site voltage.
| Indicator | State | Meaning and first action |
| Chassis browns out on a load step | Voltage dip | The 75 W output budget is shared by all rails; an added 24 V load can exhaust it before the 5.1 V current limit is reached. |
| Supply restarts on a short | Inrush | Inrush is 20 A on the AC unit and 30 A on the DC unit; confirm the upstream breaker tolerates repeated energisation. |
| Hold-up shorter than expected | — | Hold-up is published in cycles at a stated input and load, not as a fixed millisecond figure. |
Input, output and hold-up figures per Rockwell publication 1756-TD005-EN-E and 1756-IN050.
Check the 5.1 V current total, not the slot count. A chassis that ran on a PA72 and trips after adding analog modules is over the 10 A rail, and the PA75 is the correct answer rather than a replacement PA72.
Verify the chassis series before ordering. A series A chassis cannot mount a PA75, and forcing the issue damages the connector rather than the supply.
Record the hold-up at the panel's actual voltage. A site running 208 V has six cycles, not the twenty quoted at 220 V.
What is the 1756-PA75?
A standard ControlLogix AC power supply, 75 W output, 13 A at 5.1 V DC.
How does it differ from the 1756-PA72?
Same 75 W and same package, but 13 A at 5.1 V instead of 10 A, and it fits series B and C chassis only.
What input voltage does it accept?
85…265 V AC at 47…63 Hz, nominal 120/240 V AC.
What current is available at 24 V DC?
2.8 A.
What is the hold-up time?
2 cycles at 85 V AC, 6 cycles at 120 V AC and 20 cycles at 220 V AC, 60 Hz.
Which chassis does it fit?
1756-A4, A7, A10, A13 and A17 chassis in series B or C.
What is the maximum inrush current?
20 A.
Can it be used in a redundant system?
Yes — two 1756-PA75R supplies with a 1756-PSCA2 adapter form the 1756-PAR2 kit.
Data sources. Technical values on this page come from Rockwell publications 1756-TD005 (ControlLogix Power Supplies Specifications) - input, output, hold-up, isolation and environmental data for 1756-PA75; 1756-SG001 (ControlLogix System Selection Guide) - chassis and supply selection and the manufacturer's product page for 1756-PA75. Values re-checked 16 November 2026.