The 1794-OA16 switches sixteen 220V AC loads in one FLEX I/O slot, at 500 mA per channel and 4.0 A for the module, with 2.5 A fusing specified by Rockwell.
It is the dense variant of the AC output line: a European-style 230V panel with sixteen solenoids or small contactors fits one island instead of two.
| 1794-IA8 | 8-point 120V AC input module | IN STOCK |
| 1794-IA8I | 8-point 120V AC input module, 1240V isolation | IN STOCK |
| 1794-IA16 | 16-point 120V AC input module | IN STOCK |
| 1794-IA16K | 16-point 120V AC input module, conformal coated | IN STOCK |
| 1794-IM8 | 8-point 240V AC input module | IN STOCK |
| 1794-IM16 | 16-point 240V AC input module | IN STOCK |
| 1794-OA8 | 8-point 120V AC output module | IN STOCK |
| 1794-OA8I | 8-point 120V AC isolated output module | IN STOCK |
| 1794-OA8K | 8-point 120V AC output module, conformal coated | IN STOCK |
| 1794-OA16 | 16-point 220V AC output module | IN STOCK |
| 1794-OA16K | 16-point 220V AC output module, conformal coated | IN STOCK |
| 1794-OM8 | 8-point 240V AC output module | IN STOCK |
| 1794-OM16 | 16-point 240V AC output module | IN STOCK |
Application |
FLEX I/O digital output, 1794 terminal base |
Cat Num |
1794-OA16 |
Brand Name |
Rockwell |
Outputs |
16, AC |
Load voltage |
159V AC minimum, 264V AC maximum |
Output current |
500 mA per channel at 55 deg C; 4.0 A per module (16 x 250 mA) |
Off-state leakage |
2.5 mA maximum |
On-state voltage drop |
1.5V at 0.5 A |
Surge current |
7 A for 40 ms, repeatable every 8 s |
Isolation |
2600V DC for 1 s |
Power dissipation |
4.7 W (16.1 BTU/hr) |
Fusing |
2.5 A 150V M02 fuse |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Sixteen outputs over 159...264V AC, 500 mA per channel at 55 deg C, 4.0 A for the module.
4.0 A across sixteen channels averages 250 mA, which is the figure to use when all sixteen are energised at once.
2.5 mA off-state leakage and 1.5V drop at 0.5 A — the leakage is higher than the 120V card, so a small relay coil needs a bleeder.
7 A surge for 40 ms every 8 s is shorter than the 120V card's 45 ms, which suits the smaller inrush of a 230V load bank.
The load voltage window is 159...264V AC, wide enough for a nominal 220V or 230V supply with normal tolerance.
Two outputs on the same phase share the module total; splitting the load across phases does not raise the 4.0 A ceiling.
Minimum load and leakage both matter on a 230V circuit: a 230V relay coil can be held by 2.5 mA more easily than a 120V one.
Suppression at the coil is required for the same reason as on the 120V card: the triac is turned off by the inductive kick every half cycle.
Not for DC loads. The output stage is an AC switch; a DC solenoid on this card will not release.
2.5 A 150V M02 fuse is the published protection, fitted at the base or in the panel.
The 2.5 A rating reflects the group current, not the per-channel 500 mA: the fuse sits where the wiring and the triac meet.
Fast or slow characteristic? The publication names the M02 type; substituting a general-purpose fuse changes the protection curve and is not equivalent.
Where a fused base is used, the fuse sits at the terminal and the field wiring is protected without a remote block.
2600V DC for 1 s is the published isolation test, higher than the 120V AC output card's 2150V DC.
0...55 deg C operating range excludes cold-start duty, unlike the 120V output cards rated from -20 deg C.
4.7 W (16.1 BTU/hr) is the module heat at rated load, which the enclosure has to remove along with the rest of the island.
Sixteen channels on one slot save an adapter, a base and a rail length compared with two eight-point cards.
Check the phase and neutral at each terminal before energising: a 230V output on a mislabelled 120V circuit is a fault waiting to happen.
Test one channel at a time with the field device, then the bit, then the program — the same three-step separation as on any output card.
Fuse continuity first on a channel that will not switch; the triac is more often intact than the fuse.
Field terminals on the base, keying checked before insertion, latch locked after — the standard insertion sequence.
How many outputs has the 1794-OA16?
Sixteen AC outputs, 500 mA per channel at 55 deg C, 4.0 A per module.
What load voltage does it accept?
159V AC minimum to 264V AC maximum, which covers 220V and 230V supplies.
What fuse is specified?
A 2.5 A 150V M02 fuse.
What is the isolation rating?
2600V DC for 1 s, field to system.
What is the operating temperature range?
0...55 deg C, narrower than the -20...55 deg C of the 120V AC output cards.
What off-state leakage should be expected?
2.5 mA maximum, which can hold a light relay coil unless a bleeder resistor is fitted.
1794-OA16 is the sixteen-channel AC member of the four AC and relay output modules this site carries, and it is the one whose printed per-channel and per-module currents do not reconcile at full load. The two tables below hold the four side by side as their records print them.
| Catalog number | Outputs | Load window as printed | Per-channel and module current | Isolation as printed | Fuse as printed |
|---|---|---|---|---|---|
| 1794-OA8I | 8, AC | 85 V AC to 132 V AC | 5 mA minimum; 500 mA per channel at 55 C and 750 mA at 35 C; 4.0 A per module | 2150 V DC for 1 s; 1250 V AC for 60 s | 1.6 A 250 V slow-blow |
| 1794-OA16 | 16, AC | 159 V AC to 264 V AC | 500 mA per channel at 55 C; 4.0 A per module, printed as 16 x 250 mA | 2600 V DC for 1 s | 2.5 A 150 V M02 |
| 1794-OM8 | 8, AC | not printed on the record | 500 mA per channel; 4.0 A per module | 250 V basic; 1250 V AC for 60 s | not printed on the record |
| 1794-OW8 | 8, Form A normally open relay, isolated | 2 A at 5 to 30 V DC, 0.22 A at 125 V DC, 2 A at 125 V AC, 2 A at 250 V AC | a contact rating rather than a channel current | 250 V basic relay to relay, to backplane and to power; 1500 V AC 60 s, 3250 V DC 60 s | 3.0 A 250 V slow-blow |
| Catalog number | Operating temperature as printed | Power dissipation | Leakage or off-state | Surge as printed |
|---|---|---|---|---|
| 1794-OA8I | -20 to 55 C | 4.1 W (14.0 BTU/hr) | 2.25 mA maximum | 7 A for 45 ms, repeatable every 8 s |
| 1794-OA16 | 0 to 55 C | 4.7 W (16.1 BTU/hr) | 2.5 mA maximum | 7 A for 40 ms, repeatable every 8 s |
| 1794-OM8 | 0 to 55 C | 5 W (17.1 BTU/hr) | 2.5 mA maximum | 7 A for 40 ms |
| 1794-OW8 | -20 to 55 C | 5.5 W at 31.2 V DC (18.8 BTU/hr) | 100 uA at 100 mV minimum load | 10 ms on and off delay, 1.2 ms bounce |
Sixteen channels and a module ceiling printed as 16 x 250 mA is the number to read twice: the per-channel figure is 500 mA, and the module total of 4.0 A works out to 250 mA averaged across sixteen. Sixteen loads at 500 mA would be eight amps, twice the ceiling, so half the channels at full rating or all sixteen at half rating is what the printed figures allow.
Fusing is where the four diverge most quietly: 1.6 A at 250 V on the OA8I, 3.0 A at 250 V on the relay module, and on the OA16 a 2.5 A 150 V fuse printed under a load window that reaches 264 V AC. The last of those is the record printing what it prints; a fuse rated to 150 V on a module whose published load window goes to 264 V AC is the kind of row a panel builder should query rather than copy.
What the four records do not settle between them: no terminal base compatibility row on any of them, no backplane current draw, no wiring diagram, no statement of which of them can share a base with which adapter, no lifecycle field on any of the four, and no fuse rating at all on the OM8. The load window on the OM8 and the 150 V fuse on the OA16 are the two rows to query before an order rather than after.
Source: the published rows of 1794-OA8I, 1794-OA16, 1794-OM8 and 1794-OW8 as printed on this site - output counts and types, load windows, per-channel and per-module currents, contact ratings, minimum load, on and off delay, bounce, contact resistance, switching frequency, mechanical life, fuses, isolation strings, external supply current, power dissipation, leakage, surge, and operating temperature. Rows a record does not print are marked as not printed rather than filled in; the 93 hour figure for the relay is the published 100,000 operations divided by the published 0.3 Hz.
The Allen-Bradley Flex I/O 1794 modules category lists the related catalog numbers, options and accessories for this range.