Product Details:
Payment & Shipping Terms:
|
1783-ETAP is an EtherNet/IP tap: a small device that lets several nodes join a device-level ring without a switch, and that keeps that ring intact when a node is unplugged.
It is what makes a line-level ring practical — the tap owns the ring ports, so the controller needs only one Ethernet connection.
| 1783-BMS20CL | Stratix 5700, 20 ports, 16 copper + 2 combo + 2 SFP | IN STOCK |
| 1783-BMS20CGP | Stratix 5700, 20 ports, gigabit combo | IN STOCK |
| 1783-BMS20CGL | Stratix 5700, 20 ports, gigabit combo, Lite firmware | IN STOCK |
| 1783-BMS20CGPK | Stratix 5700, 20 ports, gigabit combo, kit | IN STOCK |
| 1783-BMS06TA | Stratix 5700, 6 copper ports | IN STOCK |
| 1783-BMS06TL | Stratix 5700, 6 copper ports, Lite firmware | IN STOCK |
| 1783-BMS06TGA | Stratix 5700, 4 copper + 2 gigabit copper | IN STOCK |
| 1783-BMS06SA | Stratix 5700, 4 copper + 2 SFP | IN STOCK |
| 1783-BMS06SL | Stratix 5700, 4 copper + 2 SFP, Lite firmware | IN STOCK |
| 1783-BMS06SGA | Stratix 5700, 4 copper + 2 gigabit SFP | IN STOCK |
| 1783-BMS06SGL | Stratix 5700, 4 copper + 2 gigabit SFP, Lite firmware | IN STOCK |
| 1783-MS06T | Stratix 8000, 6 port chassis | IN STOCK |
| 1783-MS10T | Stratix 8000, 10 port chassis | IN STOCK |
| 1783-RMS06T | Stratix 8300, 6 port layer 3 | IN STOCK |
| 1783-RMS10T | Stratix 8300, 10 port layer 3 | IN STOCK |
| 1783-EMS04T | Stratix 6000, 4 port managed | IN STOCK |
| 1783-MX08T | Stratix 8000 copper 8 port expansion | IN STOCK |
| 1783-MX08F | Stratix 8000 fibre 8 port expansion | IN STOCK |
| 1783-MCF | Stratix 8000 CompactFlash spare card | IN STOCK |
| 1783-RMCF | Stratix 8300 CompactFlash spare card | IN STOCK |
| 1783-ETAP | EtherNet/IP tap, 3 copper ports | IN STOCK |
| 1783-ETAP2F | EtherNet/IP tap, 1 copper + 2 fibre | IN STOCK |
| 1783-SFP100FX | 100FX multimode SFP, 2 km | IN STOCK |
| 1783-SFP100LX | 100LX singlemode SFP, 10 km | IN STOCK |
| 1783-SFP1GSX | 1000SX multimode SFP, 550 m | IN STOCK |
| 1783-SFP1GLX | 1000LX singlemode SFP, 10 km | IN STOCK |
| 1783-US8T | Stratix 2000, 8 copper ports, unmanaged | IN STOCK |
| 1783-US03T01F | Stratix 2000, 3 copper + 1 fibre, unmanaged | IN STOCK |
Catalog number |
1783-ETAP |
Description |
EtherNet/IP tap |
Ports |
3 copper RJ45 ports |
Interface |
3 * copper RJ45 |
Power supply |
24V dc |
Lifecycle status |
Discontinued May 31, 2026 |
Replacement category |
Functional Replacement |
Replacement product |
1783-ETAP3T |
Country of origin |
United States |
Publication |
1783-UM011 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1783-UM011 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
3 copper RJ45 ports, powered from 24V dc.
In a device-level ring (DLR) the tap sits between the two ring ports and presents one copper port to the device. Losing the device does not break the ring; losing the tap does.
Where the controller has a single Ethernet port and the topology has to survive a cable break — a conveyor line, a packaging machine, a process skid.
Where a managed switch would be overkill: a tap has no management, no addressing plan and nothing to configure.
1783-ETAP is three copper ports; 1783-ETAP2F is one copper port plus two fibre ports for a ring that crosses between cabinets.
Fibre on the ring is what makes the distance work. Copper taps stop at the enclosure wall for practical reasons, not because the standard forbids more.
Discontinued May 31, 2026, replacement category Functional Replacement, replacement product 1783-ETAP3T.
Taps are overlooked in spares planning because they look passive. A line with ten taps and no spare stops at the first failed tap.
Check the ports for bent pins and confirm which variant the unit is — copper and fibre taps look similar from the front.
Country of origin for this catalog number is the United States, which matters for lead time on any remaining new stock.
What is 1783-ETAP?
An EtherNet/IP tap — 3 copper RJ45 ports.
What power does 1783-ETAP need?
24V dc.
Is 1783-ETAP still available from Rockwell?
No. Discontinued May 31, 2026; replacement category Functional Replacement.
What replaces 1783-ETAP?
1783-ETAP3T
Where is 1783-ETAP used?
In device-level rings, to keep the ring intact when a device is disconnected.
1783-ETAP is part of the Allen-Bradley Stratix industrial Ethernet range, described here from the Rockwell technical data and installation instructions so that the supply, the isolation and the temperature limits on the page are the ones an integrator can actually design against.
| Specification | Value |
|---|---|
| Tap type | Copper EtherNet/IP tap, three copper ports |
| Current consumption | 125 mA maximum at 24V DC |
| Power | 3 W consumption, 3 W dissipation |
| Supply rating | 24V DC, 20.4 to 27.6V DC, Class 2 or SELV |
| Isolation | 30V continuous basic insulation, network channels to power and network to network; type tested 1250V DC for 60 s |
| Wire size, power | One 0.33 to 3.3 mm2 (22 to 12 AWG) or two 0.33 to 1.3 mm2 (22 to 16 AWG) copper rated 75 degrees C |
| Terminal torque | 0.6 to 0.8 N m (5 to 7 in lb) on the power terminal |
| Temperature code | T5 for North America, T5 for IEC |
| Enclosure | None, open style |
| Source | 1783-TD002D-EN-P, May 2023 |
A tap is the cheapest way to add a device to an EtherNet/IP segment that already exists. It presents three copper ports, takes its 3 W from the same 24V supply as everything else in the cabinet, and requires no configuration file. Where the segment is a linear drop from a switch, the tap is what lets a second device join without re-pulling the home run.
The temperature code is worth reading twice on this part: T5 rather than the T4 that most of the range carries. In a hazardous area assessment the code drives the maximum surface temperature calculation, so a T5 part and a T4 part are not interchangeable just because both are 24V devices.
Two attributes in the table decide more installations than the port count does: the supply range, because a 24V nominal device with a 20.4V lower limit behaves differently from one that accepts 12V, and the surrounding air limit, because a switch rated at 60 degrees C in a cabinet designed for 70 degrees C is a thermal problem rather than a network problem.
Device Level Ring is the reason many of these switches exist in a machine line. A ring built from two ports per device survives one open cable without dropping the cell, and the recovery time is a property of the ring rather than of any single switch, so a mixed vendor ring has to be checked as a whole.
The emission class is CISPR 11 Class A, which is an industrial environment statement. Mounting one of these in a light industrial or residential panel can require additional filtering, and that is a compliance question rather than a performance one, so it belongs in the quotation stage.
The distance an SFP reaches is a property of the optic and the fiber, not of the switch. Multimode runs to a few hundred meters, singlemode runs to kilometers, and the budget has to cover connectors and splices, so the link loss calculation belongs in the same document as the port list.
An unmanaged switch has no address and no configuration, so it either forwards frames or it does not. That is a feature in a machine cell where nobody wants a config file to restore after a controller swap, and it is a liability in a line where someone needs to know which port dropped a packet.
On 1783-ETAP conformal coating is a suffix rather than a separate product, and it matters in washdown or sulfur bearing atmospheres. Where a cabinet sits in a food plant or near a rubber process, the coated variant is the one to quote, because condensation on an uncoated board is a failure that shows up months later.
Commissioning a switch takes an afternoon the first time and twenty minutes afterwards: address it, set the ring or the redundant path, confirm the port counters stay clean under load, and record the firmware revision on the as-built drawing. The failures that survive to production are almost always a duplicate address or a loop nobody documented.
On 1783-ETAP the 24V DC input is Class 2 or SELV, which is what allows a cabinet to feed them from the same distribution as the PLC without a separate transformer. Where a site still runs 24V AC, that option exists on the unmanaged range and disappears on the managed ones, and the difference is worth checking before a retrofit order is placed.
Precision time is a separate question from data. IEEE 1588 CIP Sync is what lets a controller timestamp an input at the switch edge rather than at the scanner, and only the Full firmware variants carry it. If an application needs coordinated motion or sequence of events, the Lite part on the shelf will not do the job.
Temperature is quoted at the surrounding air rather than at the board, and the 60 degrees C ceiling on the managed units is lower than the 70 degrees C that the FLEX Ex and most I/O families allow. A cabinet that was designed around an I/O module rating will need a thermal review before a switch is added at the top of the rail.
A switch that has been in a cabinet for eight years, 1783-ETAP among them, is usually still electrically sound and functionally obsolete. The practical question at replacement time is whether the firmware can still be managed by the current tool, and a unit that cannot be reached by the engineering software is a unit that will be replaced on failure rather than on schedule.
A managed switch adds the diagnostics that make a network debuggable: port level counters, spanning tree, and in the Stratix range a Device Level Ring that survives a single cable break. The catalog suffix tells you whether that firmware is present, and a Lite unit is not upgradeable into a Full one by flashing it. For 1783-ETAP the suffix is the only reliable statement of which firmware set ships.
Every one of these units, 1783-ETAP included, is open style, which means it belongs in an enclosure with a pollution degree 2 environment. The IP30 rating protects against fingers and tools, not against water, and a switch mounted on an open panel in a wet area is a warranty claim waiting to happen.
Cybersecurity hardening starts at the switch, not at the firewall. Disabling unused ports, changing the default credentials, and keeping the management interface off the plant backbone are the three steps that close most findings in an industrial network assessment, and none of them require a licence.
Ethernet ports are rated for Category 5e cable at minimum, and the connector is the IEC 60603-7 RJ45 that every industrial patch cord already uses. Where a cabinet is wired with older Category 5 cable, the link will usually train at 100 Mbps but the error counters will climb, which is why the cable class is printed next to the port table.
Check the T5 temperature code against the area classification, keep the tap on the same 24V SELV feed as the segment it serves, and record the port usage on the as-built drawing.
The Allen-Bradley 1783 network switches category groups the other catalog numbers, options and spare parts in the same range.