Allen Bradley PLC 1734-OA4 / 1734OA4

China Allen Bradley PLC 1734-OA4 / 1734OA4 supplier
Allen Bradley PLC 1734-OA4 / 1734OA4 supplier Allen Bradley PLC 1734-OA4 / 1734OA4 supplier Allen Bradley PLC 1734-OA4 / 1734OA4 supplier Allen Bradley PLC 1734-OA4 / 1734OA4 supplier Allen Bradley PLC 1734-OA4 / 1734OA4 supplier Allen Bradley PLC 1734-OA4 / 1734OA4 supplier Allen Bradley PLC 1734-OA4 / 1734OA4 supplier Allen Bradley PLC 1734-OA4 / 1734OA4 supplier Allen Bradley PLC 1734-OA4 / 1734OA4 supplier

Large Image :  Allen Bradley PLC 1734-OA4 / 1734OA4

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1734-OA4 / 1734OA4

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $76.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 30 PCS
Detailed Product Description

1734-OA4 technical data PDF download POINT I/O 1734-OA4 / 1734OA4 4-Point 120/220V AC Output Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O Digital Output

The 1734-OA4 puts four 120/220V AC triac outputs in one POINT I/O slice, 750 mA per channel and 2.0 A for the module, with the same 74 to 264V AC window and 10 mA minimum load as the two-point version.

The module is the hotter of the two: 3.5 W at 264V AC and a 30% derating from 45 °C to 55 °C, which is the figure that decides how many channels can be loaded in a warm cabinet.

1734-OA2 2 triac AC outputs, 74...264V AC, 0.75 A per channel, 1.5 A per module IN STOCK
1734-OA4 4 triac AC outputs, 74...264V AC, 0.75 A per channel, 2.0 A per module IN STOCK

Product Specifications 1734-OA4 (PDF)
 Outputs per module
 4, non-isolated, sourcing
 Output current rating
 2.0 A (750 mA per output, 2.0 A max per module)
 Current versus temperature
 2.0 A per module at 45 deg C, derate 30% to 1.4 A at 55 deg C
 On-state voltage, min
 74V AC
 On-state voltage, nominal
 120/220V AC
 On-state voltage, max
 264V AC
 On-state voltage drop, max
 1.0V @ 0.75 A
 On-state current, min per channel
 10 mA
 On-state current, max per channel
 750 mA
 Off-state leakage, max
 2.7 mA @ 264V AC
 Surge current
 16 A for 100 ms, repeatable every 10 s
 Turn-off time
 1/2 cycle
 POINTBus current, max
 75 mA @ 5V DC
 Isolation voltage
 240V (continuous), Reinforced Insulation, tested 3250V DC for 60 s, field side to system
 External AC supply
 120/220V AC at 60 Hz
 Terminal base screw torque
 0.8 Nm (7 lb-in)
 Dimensions, HxWxD
 56.0 x 12.0 x 75.5 mm
 Wiring category
 1 - on signal ports
 Temperature code
 T4 (North American)
 Operating temperature
 -20...55 °C
 Power dissipation, max
 3.5 W @ 264V AC
 Thermal dissipation, max
 11.9 BTU/hr @ 264V AC
 Weight, approx
 30.9 g
 Field wiring terminations
 0/1/2/3 - Channels 0/1/2/3, 4/5 - L2/N, 6/7 - L1
 Indicators
 4 output status, module and network status

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN009-EN-E (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-OA4 original product photograph, wide view 1734-OA4 original product photograph, label view 1734-OA4 original product photograph, second unit

Four channels on one AC supply

Terminals 0 to 3 are the four channels; 4 and 5 are L2/N and 6 and 7 are L1. All four loads share the same AC supply and return, so this module suits a bank of AC solenoids or four indicator lamps on one machine section, not a mix of 120V and 230V circuits.

Derating: 2.0 A at 45 °C, 1.4 A at 55 °C

A 30% derating is steep compared with the two-point module's 13%. Four channels at 0.5 A total 2.0 A and are at the limit at 45 °C; at 55 °C the same slice can only carry 1.4 A, so the practical loading is 0.35 A per channel. Design the load list against the cabinet temperature, not the data sheet headline.

Thermal and cabinet consequences

3.5 W, 11.9 BTU/hr, is the highest dissipation of the 1734 digital output modules. In a 12 mm-wide slice that is a real hot spot, and the enclosure temperature rise calculation must include it - which then feeds back into the derating above.

Leakage on four channels

2.7 mA at 264V AC per channel. With four channels on one base the total leakage into a connected load bank is more noticeable than on a two-point module, so small AC relays and neon lamps remain a poor fit; use 1734-OW4 for contact outputs.

Isolation and wiring rules

240V reinforced isolation tested at 3250V DC for 60 s separates the mains side from the POINTBus. Terminal base torque is 0.8 Nm and the base options are 1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS; wiring category is 1 on signal ports.

FAQ — 1734-OA4

What load types can a 1734-OA2 switch?

The triac output is for AC loads between 10 mA and 750 mA per channel at 74 to 264V AC. Resistive and inductive AC loads such as solenoids, contactors and lamps work; the published on-state drop is 1.0V at 0.75 A and off-state leakage is 2.7 mA at 264V AC.

Why does the module have a derating curve?

Because the triac dissipates heat that depends on load current and ambient. 1734-OA2 carries 1.5 A total up to 50 deg C and derates linearly by 13% to 1.3 A at 55 deg C; 1734-OA4 carries 2.0 A up to 45 deg C and derates by 30% to 1.4 A at 55 deg C. A cabinet at 55 deg C cannot use the headline current rating.

Can these modules switch DC loads?

No. The output stage is a triac for AC only, with a 1/2 cycle turn-off. For DC loads use the sourcing 1734-OB family or the sinking 1734-OV family, or a 1734-OW relay module if isolation between the load circuit and the module is required.

What is the surge capability?

16 A for 100 ms, repeatable every 10 s, which covers the inrush of small AC solenoids and incandescent lamps. It does not cover a motor start every few seconds.

What isolation does the AC output provide?

240V continuous reinforced insulation, tested at 3250V DC for 60 s from field side to system - the highest test voltage in the 1734 digital family, which is why mains circuits can sit on the same slice as 24V DC I/O.

Is 1734-OA4 a drop-in replacement for 1734-OA2?

It fits the same bases and uses the same 74...264V AC window, but the module current rating and derating are different - 2.0 A at 45 deg C against 1.5 A at 50 deg C - and the terminal pattern changes from 2/3 no-connection to four channel terminals. Rewire the base rather than swapping the module in place.


Data sources. Technical values on this page come from Rockwell publication 1734-IN009-EN-E (POINT I/O 120V and 220V AC Output Modules, catalog numbers 1734-OA2, 1734-OA4, 1734-OA4K, Series C) and 1734-UM001 (POINT I/O Digital and Analog Modules User Manual). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.