logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IB16I / 1756IB16I

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IB16I / 1756IB16I

China Allen Bradley PLC 1756-IB16I / 1756IB16I supplier
Allen Bradley PLC 1756-IB16I / 1756IB16I supplier Allen Bradley PLC 1756-IB16I / 1756IB16I supplier Allen Bradley PLC 1756-IB16I / 1756IB16I supplier Allen Bradley PLC 1756-IB16I / 1756IB16I supplier Allen Bradley PLC 1756-IB16I / 1756IB16I supplier Allen Bradley PLC 1756-IB16I / 1756IB16I supplier

Large Image :  Allen Bradley PLC 1756-IB16I / 1756IB16I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IB16I / 1756IB16I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $335.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IB16I technical data PDF download 1756-IB16I ControlLogix 16 Point Isolated DC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IB16I (also written 1756IB16I) is the individually isolated 16-point DC input module: operating range 10...30 V DC, maximum input current 10 mA, backplane load 135 mA at 5.1 V DC and 3 mA at 24 V DC (1756-IN062).

The word that sells this module is input-to-input. Where the plain 1756-IB16 provides 250 V reinforced isolation to the backplane and 250 V basic between groups but none inside a group, the IB16I isolates the inputs from one another — the arrangement needed when each channel comes from a different field circuit or a different supply.

That isolation is why the backplane figure is 135 mA rather than 100 mA: per-channel isolation is hardware, and it is paid for in current and in price. A design that specifies the IB16I 'for safety' without needing channel isolation is paying for a feature it will not use.

Published record: active lifecycle, estimated lead time 5 days, one year warranty. Technical data 1756-TD002, user manual 1756-UM058, installation instructions 1756-IN062.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IB16I
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IB16I isolated input product photograph 1756-IB16I terminal side product photograph 1756-IB16I module view product photograph

Where the module sits in a typical system

The IB16I belongs where inputs genuinely come from separate sources: a line with several suppliers' equipment, a retrofit where each machine keeps its own 24 V supply, or an installation where a common between two circuits would be a fault path.

It is also the module for instrument-adjacent contacts — dry contacts from third-party skids — where the panel has to prove that one skid's earth does not reach another's.

Where all inputs share one 24 V supply and one earth, the plain IB16 does the same job for less backplane current and less money; specifying the I variant there is a documentation habit, not an engineering need.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  135 mA backplane  35 % more than the plain IB16, for the same 10 mA input current. Budget it in a full chassis.
 Check 3  10...30 V DC  The same narrower window as the diagnostic module, not the 31.2 V of the IB16.
 Check 4  Mixed field supplies  This is the module for channels fed from different supplies or different machines, where a common group would create an unintended path.
 Check 5  Wiring still needs discipline  Channel isolation does not remove the need for correct conductor category and routing; keep category 1 separation.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The plain module is 1756-IB16: 10...31.2 V DC, 10 mA, 100 mA backplane, reinforced to backplane, group-to-group only.

The diagnostic module is 1756-IB16D: 10...30 V DC, 13 mA, 150 mA backplane, diagnostics on channels.

The sequence-of-events module is 1756-IB16ISOE: 10...55 V DC, 5.1 mA, 320 mA backplane, with time-stamped capture.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IB16I ControlLogix 16 Point Isolated DC Input | Rockwell

What is the 1756-IB16I?

A 16-point sinking DC input module with input-to-input isolation, 10...30 V DC, 10 mA maximum input current.

What does 'isolated' add?

250 V continuous basic insulation between inputs themselves, in addition to inputs-to-backplane — the plain IB16 does not isolate individual inputs.

What is the backplane current?

135 mA at 5.1 V DC and 3 mA at 24 V DC, per 1756-IN062.

When should I specify it?

When channels are fed from different field supplies or different machines, and a shared common would create a fault path.

Is its input range the same as the IB16?

No — 10...30 V DC, against 10...31.2 V DC on the IB16.

Is it diagnostic too?

No. Diagnostics are the IB16D; isolation and diagnostics are different features on different modules.

What is the input current per point?

10 mA maximum, the same as the plain IB16.

What documents cover it?

1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IB16I. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)