Product Details:
Payment & Shipping Terms:
|
The 1756-IB16I (also written 1756IB16I) is the individually isolated 16-point DC input module: operating range 10...30 V DC, maximum input current 10 mA, backplane load 135 mA at 5.1 V DC and 3 mA at 24 V DC (1756-IN062).
The word that sells this module is input-to-input. Where the plain 1756-IB16 provides 250 V reinforced isolation to the backplane and 250 V basic between groups but none inside a group, the IB16I isolates the inputs from one another — the arrangement needed when each channel comes from a different field circuit or a different supply.
That isolation is why the backplane figure is 135 mA rather than 100 mA: per-channel isolation is hardware, and it is paid for in current and in price. A design that specifies the IB16I 'for safety' without needing channel isolation is paying for a feature it will not use.
Published record: active lifecycle, estimated lead time 5 days, one year warranty. Technical data 1756-TD002, user manual 1756-UM058, installation instructions 1756-IN062.
1756-IB16 |
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293 |
In stock |
1756-IB16D |
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA |
In stock |
1756-IB16I |
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA |
In stock |
1756-IB16IF |
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA |
In stock |
1756-IB16ISOE |
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA |
In stock |
1756-IB32 |
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309 |
In stock |
1756-IC16 |
16 inputs, 30...60 V DC, backplane per 1756-IN062 |
In stock |
1756-IG16 |
16 TTL inputs, backplane per 1756-IN062 |
In stock |
1756-IV16 |
16 inputs, 48 V DC, backplane per 1756-IN062 |
In stock |
Application |
Discrete input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-IB16I |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
16 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Digital Input Module |
UNSPSC |
— |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The IB16I belongs where inputs genuinely come from separate sources: a line with several suppliers' equipment, a retrofit where each machine keeps its own 24 V supply, or an installation where a common between two circuits would be a fault path.
It is also the module for instrument-adjacent contacts — dry contacts from third-party skids — where the panel has to prove that one skid's earth does not reach another's.
Where all inputs share one 24 V supply and one earth, the plain IB16 does the same job for less backplane current and less money; specifying the I variant there is a documentation habit, not an engineering need.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | 135 mA backplane | 35 % more than the plain IB16, for the same 10 mA input current. Budget it in a full chassis. |
| Check 3 | 10...30 V DC | The same narrower window as the diagnostic module, not the 31.2 V of the IB16. |
| Check 4 | Mixed field supplies | This is the module for channels fed from different supplies or different machines, where a common group would create an unintended path. |
| Check 5 | Wiring still needs discipline | Channel isolation does not remove the need for correct conductor category and routing; keep category 1 separation. |
Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.
The plain module is 1756-IB16: 10...31.2 V DC, 10 mA, 100 mA backplane, reinforced to backplane, group-to-group only.
The diagnostic module is 1756-IB16D: 10...30 V DC, 13 mA, 150 mA backplane, diagnostics on channels.
The sequence-of-events module is 1756-IB16ISOE: 10...55 V DC, 5.1 mA, 320 mA backplane, with time-stamped capture.
What is the 1756-IB16I?
A 16-point sinking DC input module with input-to-input isolation, 10...30 V DC, 10 mA maximum input current.
What does 'isolated' add?
250 V continuous basic insulation between inputs themselves, in addition to inputs-to-backplane — the plain IB16 does not isolate individual inputs.
What is the backplane current?
135 mA at 5.1 V DC and 3 mA at 24 V DC, per 1756-IN062.
When should I specify it?
When channels are fed from different field supplies or different machines, and a shared common would create a fault path.
Is its input range the same as the IB16?
No — 10...30 V DC, against 10...31.2 V DC on the IB16.
Is it diagnostic too?
No. Diagnostics are the IB16D; isolation and diagnostics are different features on different modules.
What is the input current per point?
10 mA maximum, the same as the plain IB16.
What documents cover it?
1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IB16I. Values re-checked 15 November 2026.