Allen Bradley PLC 1756-IB16 / 1756IB16 supplier Allen Bradley PLC 1756-IB16 / 1756IB16 supplier Allen Bradley PLC 1756-IB16 / 1756IB16 supplier Allen Bradley PLC 1756-IB16 / 1756IB16 supplier Allen Bradley PLC 1756-IB16 / 1756IB16 supplier Allen Bradley PLC 1756-IB16 / 1756IB16 supplier Allen Bradley PLC 1756-IB16 / 1756IB16 supplier Allen Bradley PLC 1756-IB16 / 1756IB16 supplier Allen Bradley PLC 1756-IB16 / 1756IB16 supplier

Large Image :  Allen Bradley PLC 1756-IB16 / 1756IB16

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IB16 / 1756IB16

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $198.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IB16 technical data PDF download 1756-IB16 ControlLogix 16 Point DC Input Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IB16 (also written 1756IB16) is the 16-point sinking DC input module: 16 inputs in 8-point groups, operating range 10...31.2 V DC, maximum input current 10 mA, backplane load 100 mA at 5.1 V DC and 2 mA at 24 V DC (1756-IN062).

Its isolation is the detail that separates it from the cheaper-looking alternatives: 250 V continuous reinforced insulation from inputs to backplane, 250 V basic insulation between input groups, and no isolation between the individual inputs inside a group. That combination is why the IB16 is the default general-purpose choice rather than the D or I variant.

The published input range is 10...31.2 V DC against a 24 V DC nominal field supply. The upper end is 1.2 V above nominal, which accommodates a supply at its tolerance limit — but a 32 V rail is outside the specification, and a design that assumes otherwise is relying on the field supply never being adjusted.

Published record: UPC 612598171293, active lifecycle, estimated lead time 5 days, country of origin multiple, one year warranty. Technical data is 1756-TD002, the module user manual 1756-UM058 and the installation instructions 1756-IN062.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IB16
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IB16 input module product photograph 1756-IB16 terminal side product photograph 1756-IB16 label detail product photograph

Where the module sits in a typical system

The IB16 is the general-purpose digital input for a ControlLogix rack: limit switches, proximity sensors, pushbuttons, relay contacts, all at 24 V DC. Eight points per group makes the group boundaries a wiring decision, not an afterthought.

Because the isolation is reinforced to the backplane, the IB16 is also the natural choice where the field side and the control side are on separate supplies and the panel has to demonstrate that separation.

For a mixed panel, group the inputs by field circuit — one group per machine section — so a field fault is confined to a group rather than taking the whole module's commons with it.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Group isolation  250 V between groups, none within a group. Field circuits that must be isolated from each other need separate groups or the IB16I variant.
 Check 3  Range, not nominal  10...31.2 V DC. Check the supply at its worst case, including charger boost on a battery-backed 24 V system.
 Check 4  Backplane budget  100 mA at 5.1 V DC each. Sixteen IB16 modules fill a chassis and consume 1.6 A of the 5.1 V budget before any other module.
 Check 5  Terminal block not included  The removable terminal block is a separate item. A module ordered without one cannot be wired.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The diagnostic variant is 1756-IB16D (10...30 V DC, 13 mA max, 150 mA backplane) — it adds channel diagnostics at the cost of a smaller input voltage window.

The isolated variant is 1756-IB16I (10...30 V DC, 10 mA max, 135 mA backplane), which isolates input-to-input where the application needs it.

For density, 1756-IB32 packs 32 points into one slot at 5.5 mA per point and 120 mA backplane current.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IB16 ControlLogix 16 Point DC Input Module | Rockwell

What is the 1756-IB16?

A 16-point sinking DC input module for the ControlLogix chassis, 10...31.2 V DC, 10 mA maximum input current.

What is the backplane current?

100 mA at 5.1 V DC and 2 mA at 24 V DC, per 1756-IN062.

What isolation does it provide?

250 V continuous reinforced insulation inputs-to-backplane, 250 V basic between input groups, and no isolation between individual inputs in a group.

How many inputs per group?

16 inputs arranged as 8 points per group.

Is a terminal block included?

No — the removable terminal block is a separate catalogue item.

What are the alternatives?

1756-IB16D for diagnostics, 1756-IB16I for input-to-input isolation, 1756-IB32 for 32 points in one slot.

Can it take a 32 V DC signal?

No. The published range ends at 31.2 V DC, so a supply that can reach 32 V is outside the specification.

What is the UPC?

612598171293, with an estimated lead time of 5 days.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IB16. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)