logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-TBCH / 1756TBCH

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-TBCH / 1756TBCH

China Allen Bradley PLC 1756-TBCH / 1756TBCH supplier
Allen Bradley PLC 1756-TBCH / 1756TBCH supplier Allen Bradley PLC 1756-TBCH / 1756TBCH supplier Allen Bradley PLC 1756-TBCH / 1756TBCH supplier Allen Bradley PLC 1756-TBCH / 1756TBCH supplier Allen Bradley PLC 1756-TBCH / 1756TBCH supplier Allen Bradley PLC 1756-TBCH / 1756TBCH supplier Allen Bradley PLC 1756-TBCH / 1756TBCH supplier Allen Bradley PLC 1756-TBCH / 1756TBCH supplier Allen Bradley PLC 1756-TBCH / 1756TBCH supplier

Large Image :  Allen Bradley PLC 1756-TBCH / 1756TBCH

Product Details:

Place of Origin: Made in MEXICO
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-TBCH / 1756TBCH

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $46.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 50 PCS
Detailed Product Description

1756-TBCH technical data PDF download 1756-TBCH / 1756TBCH Screw Clamp Terminal Block

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-TBCH (also written 1756TBCH) is the screw-clamp removable terminal block used on the 16- and 32-point ControlLogix I/O modules. It carries one conductor per terminal across 0.33…2.1 mm² (22…14 AWG), rated 105 °C, with 1.2 mm maximum insulation strip, and terminates at 0.5 N·m (4.4 lb·in).

It is the block most chassis are wired with, because the highest-density digital and analog modules in the catalogue list it.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Removable terminal block for I/O modules
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-TBCH
 Type
 Screw clamp terminal block
 Sub Brand
 ControlLogix
 Mounting
 Module front, keyed
 Wire Size, Single
 0.33…2.1 mm² (22…14 AWG)
 Wire Insulation
 105 °C (221 °F) or greater
 Insulation Strip
 1.2 mm (3/64 in) maximum
 Terminal Torque
 0.5 N·m (4.4 lb·in)
 Connections Per Terminal
 One
 Keying
 User-defined mechanical
 Conformal Version
 1756-TBCHS

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-TBCH terminal block product photograph 1756-TBCH, second view product photograph 1756-TBCH, third view product photograph

Where the terminal block sits in the panel

The published wire range is one conductor, 0.33…2.1 mm², and there is no double-connection option. A panel that needs two wires into one point has to use the 1756-TBNH instead, at a different torque and a smaller second wire.

Torque is 0.5 N·m (4.4 lb·in) and it is lower than the 1.36 N·m of the TBNH by design: the block is a different mechanism, and applying the heavier figure strips the screw or cracks the housing. Every Rockwell module table that lists this block repeats the same 0.5 N·m figure.

Insulation is specified at 1.2 mm (3/64 in) maximum strip, and the conductor insulation must be rated 105 °C or greater. On a chassis where ambient reaches 60 °C, a 90 °C wire is inside its own rating but the block's rating assumes the higher grade.

Which modules list it matters more than the appearance of the block: 16- and 32-point digital modules and the eight-channel HART analog output are published with TBCH or TBS6H, while 8-channel analog modules such as the OF6CI list TBNH or TBSH. Fitting a TBNH to a module that publishes TBCH leaves the keying to be set by hand.

Keying is user-defined mechanical rather than electronic. The block and the module carry a keying pair that the installer sets, and a block moved between two modules without re-keying can be inserted in the wrong place — a failure that presents as a wiring fault rather than a mechanical one.

The conformal-coated variant is 1756-TBCHS, which follows the same wire figures and adds the double-connection option at 0.33…1.3 mm² with no intermixing of solid and stranded conductors.

Commissioning in five checks

  1. Match the block to the module family first. Eight-channel analog modules list TBNH and TBSH; the HART eight-channel output lists TBCH and TBS6H. A block that fits the slot physically may still be the wrong block for the module.
  2. Use the published torque for the block in hand, not for the module: TBCH 0.5 N·m (4.4 lb·in), TBNH 1.36 N·m (12 lb·in).
  3. Decide the double-connection question before wiring. Only TBNH accepts two conductors, and only at 0.33…1.3 mm² (22…16 AWG) for the second wire.
  4. Keep the wire at 105 °C rated insulation with a 1.2 mm maximum strip; the terminal is rated for that, and a thicker insulation will not seat.
  5. Do not intermix solid and stranded wire in a double connection, and keep both conductors the same size.

Termination faults that look like module faults

A terminal block has no diagnostics of its own; the evidence is wire strip length, conductor count per terminal, the torque figure for this block and the keying pair with the module.

 Indicator  State  Meaning and first action
 Two wires will not fit  —  Only TBNH accepts a second conductor, and only 0.33…1.3 mm² (22…16 AWG) as a double connection.
 Spring terminal will not accept a second wire  —  TBSH and TBS6H are published single-connection only; do not wire multiple conductors on any terminal.
 Fault appears after a module swap  —  RTB keying is user-defined mechanical; a block keyed for another module is not interchangeable.
 Agency mark questioned on a retrofit  —  The ControlLogix system is certified using only TBCH, TBNH, TBSH and TBS6H; other terminations can need agency approval.

Wire, torque and connection limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.

Replacing a terminal block

Replace the block, not the module, when a single channel goes intermittent on a machine with vibration at the terminal.

Re-key the replacement block to the module before wiring it; a block brought from another slot is already keyed for that slot.

Torque to 0.5 N·m. A block that has been over-torqued once is usually distorted enough to need replacement.

Which ControlLogix terminal block to specify

  • 1756-TBCH — screw clamp, single connection, 0.5 N·m.
  • 1756-TBS6H — spring clamp, single connection, same wire range.
  • 1756-TBNH — screw clamp with double-connection option, 1.36 N·m.
  • 1756-TBSH — spring clamp, single connection, for 8-channel modules.
  • 1756-TBCHS / TBS6HS / TBNHS / TBSHS — conformal-coated versions for corrosive or condensing locations.

FAQ — 1756-TBCH / 1756TBCH Screw Clamp Terminal Block

What is the 1756-TBCH?

A screw-clamp removable terminal block for ControlLogix I/O modules, one conductor per terminal.

What wire size does it take?

0.33…2.1 mm² (22…14 AWG), single connection only.

What is the terminal torque?

0.5 N·m (4.4 lb·in).

Can it take two wires in one terminal?

No — the double-connection option belongs to the 1756-TBNH.

What insulation rating is required?

105 °C (221 °F) or greater, with 1.2 mm maximum strip.

Which modules use it?

16- and 32-point digital modules and the 1756-OF8H eight-channel HART output, per their specification tables.

Is there a conformal-coated version?

Yes, 1756-TBCHS, with the same wire range and a double-connection option.

Is the block keyed?

Yes, user-defined mechanical keying shared with the module.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - removable terminal block rows: wire size, conductor count, torque and keying for 1756-TBCH and the manufacturer's product page for 1756-TBCH. Values re-checked 16 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)