The 1756-TBCH (also written 1756TBCH) is the screw-clamp removable terminal block used on the 16- and 32-point ControlLogix I/O modules. It carries one conductor per terminal across 0.33…2.1 mm² (22…14 AWG), rated 105 °C, with 1.2 mm maximum insulation strip, and terminates at 0.5 N·m (4.4 lb·in).
It is the block most chassis are wired with, because the highest-density digital and analog modules in the catalogue list it.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Removable terminal block for I/O modules |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-TBCH |
Type |
Screw clamp terminal block |
Sub Brand |
ControlLogix |
Mounting |
Module front, keyed |
Wire Size, Single |
0.33…2.1 mm² (22…14 AWG) |
Wire Insulation |
105 °C (221 °F) or greater |
Insulation Strip |
1.2 mm (3/64 in) maximum |
Terminal Torque |
0.5 N·m (4.4 lb·in) |
Connections Per Terminal |
One |
Keying |
User-defined mechanical |
Conformal Version |
1756-TBCHS |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The published wire range is one conductor, 0.33…2.1 mm², and there is no double-connection option. A panel that needs two wires into one point has to use the 1756-TBNH instead, at a different torque and a smaller second wire.
Torque is 0.5 N·m (4.4 lb·in) and it is lower than the 1.36 N·m of the TBNH by design: the block is a different mechanism, and applying the heavier figure strips the screw or cracks the housing. Every Rockwell module table that lists this block repeats the same 0.5 N·m figure.
Insulation is specified at 1.2 mm (3/64 in) maximum strip, and the conductor insulation must be rated 105 °C or greater. On a chassis where ambient reaches 60 °C, a 90 °C wire is inside its own rating but the block's rating assumes the higher grade.
Which modules list it matters more than the appearance of the block: 16- and 32-point digital modules and the eight-channel HART analog output are published with TBCH or TBS6H, while 8-channel analog modules such as the OF6CI list TBNH or TBSH. Fitting a TBNH to a module that publishes TBCH leaves the keying to be set by hand.
Keying is user-defined mechanical rather than electronic. The block and the module carry a keying pair that the installer sets, and a block moved between two modules without re-keying can be inserted in the wrong place — a failure that presents as a wiring fault rather than a mechanical one.
The conformal-coated variant is 1756-TBCHS, which follows the same wire figures and adds the double-connection option at 0.33…1.3 mm² with no intermixing of solid and stranded conductors.
A terminal block has no diagnostics of its own; the evidence is wire strip length, conductor count per terminal, the torque figure for this block and the keying pair with the module.
| Indicator | State | Meaning and first action |
| Two wires will not fit | — | Only TBNH accepts a second conductor, and only 0.33…1.3 mm² (22…16 AWG) as a double connection. |
| Spring terminal will not accept a second wire | — | TBSH and TBS6H are published single-connection only; do not wire multiple conductors on any terminal. |
| Fault appears after a module swap | — | RTB keying is user-defined mechanical; a block keyed for another module is not interchangeable. |
| Agency mark questioned on a retrofit | — | The ControlLogix system is certified using only TBCH, TBNH, TBSH and TBS6H; other terminations can need agency approval. |
Wire, torque and connection limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.
Replace the block, not the module, when a single channel goes intermittent on a machine with vibration at the terminal.
Re-key the replacement block to the module before wiring it; a block brought from another slot is already keyed for that slot.
Torque to 0.5 N·m. A block that has been over-torqued once is usually distorted enough to need replacement.
What is the 1756-TBCH?
A screw-clamp removable terminal block for ControlLogix I/O modules, one conductor per terminal.
What wire size does it take?
0.33…2.1 mm² (22…14 AWG), single connection only.
What is the terminal torque?
0.5 N·m (4.4 lb·in).
Can it take two wires in one terminal?
No — the double-connection option belongs to the 1756-TBNH.
What insulation rating is required?
105 °C (221 °F) or greater, with 1.2 mm maximum strip.
Which modules use it?
16- and 32-point digital modules and the 1756-OF8H eight-channel HART output, per their specification tables.
Is there a conformal-coated version?
Yes, 1756-TBCHS, with the same wire range and a double-connection option.
Is the block keyed?
Yes, user-defined mechanical keying shared with the module.
Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - removable terminal block rows: wire size, conductor count, torque and keying for 1756-TBCH and the manufacturer's product page for 1756-TBCH. Values re-checked 16 November 2026.