The 1756-L71 (also written 1756L71) is the 2 MB member of the ControlLogix 5570 range: one chassis slot, a 1 GB Secure Digital card shipped in the slot, a removable capacitor energy storage module, and a four-character status display on the front that reports the firmware revision and the project state before anyone opens a laptop.
Published figures are 2 MB of user memory against 0.98 MB of I/O memory, maximums of 128,000 digital, 4,000 analogue and 128,000 total I/O points, 800 mA at 5.1 V DC plus 5 mA at 1.2 V DC, 2.5 W and 8.5 BTU/hr, and 30 V continuous basic insulation from the USB port to the system, compliant and tested to IEC/UL 61010-1 (1756-TD001). The controller ships with the 1756-ESMCAP installed, so there is no battery to date-code on a spare unit.
| 1756-L71 | ControlLogix 5570 controller, 2 MB user memory | IN STOCK |
| 1756-L72 | ControlLogix 5570 controller, 4 MB user memory | IN STOCK |
| 1756-L73 | ControlLogix 5570 controller, 8 MB user memory | IN STOCK |
| 1756-L71S | GuardLogix 5570 safety controller, 2 MB / 1 MB safety | IN STOCK |
| 1756-L72S | GuardLogix 5570 safety controller, 4 MB / 2 MB safety | IN STOCK |
| 1756-L73S | GuardLogix 5570 safety controller, 8 MB / 4 MB safety | IN STOCK |
| 1756-L7SP | GuardLogix 5570 safety partner, pairs with L71S / L72S / L73S | IN STOCK |
| 1756-L73XT | ControlLogix-XT 5570 controller, 8 MB, -25 to +70 C | IN STOCK |
| 1756-L73SXT | GuardLogix-XT 5570 safety controller, 8 MB / 4 MB safety | IN STOCK |
| 1756-L7SPXT | GuardLogix-XT 5570 safety partner, pairs with L73SXT | IN STOCK |
Application |
Programmable Logic Controller |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-L71 |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-L71 |
Mounting |
Chassis |
Number Of Channels |
1756-L71 |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Controller |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix controller user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.
2 MB is the size for one machine, one panel and one program: a station controller with digital and analogue I/O, a PanelView terminal on EtherNet/IP, and no integrated motion. That kind of project typically loads into a fraction of the memory, and the limit that is reached first is the tag and program structure rather than the byte count.
The 0.98 MB of I/O memory and the 128,000 point ceiling are both far above what a single-cell controller ever addresses. What matters in the field is the SD card and the ESM: the card holds the program image that lets a replacement controller come up without a laptop, and the ESM keeps the wall clock alive across a power cycle for the length of the capacitor charge.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| RUN | Steady green | Controller is in Run mode. |
| FORCE | Off | No tags contain I/O force values, or forces are disabled. |
| FORCE | Steady yellow | I/O forces are enabled. A field wiring check made now is not valid. |
| FORCE | Flashing yellow | Forced addresses exist but forces are not enabled; enabling them applies every stored force at once. |
| OK | Off | No power applied to the controller. |
| OK | Flashing red | New controller that needs a firmware update, or a major fault on a controller in service. |
| OK | Steady red | Power-up diagnostics, ESM discharge at power-down, project transfer to nonvolatile memory, or a controller that is powered but inoperable. |
| OK | Steady green | Controller operating normally. |
| Status display | TEST / PASS | Power-up tests running, then completed. |
| Status display | CHRG | Capacitor energy storage module charging; do not remove the ESM. |
| Status display | BUSY | I/O modules in the project are not yet fully powered. |
| Status display | No Project | Controller memory is empty; download the project or load it from the SD card. |
| Status display | Rev XX.xxx | Firmware major and minor revision currently installed. |
Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and 1756-IN050.
The 5570 family is the step above the discontinued 5560 controllers. An L61 or L62 rack moving to a 5570 keeps the chassis, the I/O modules and the power supplies, and gains the SD card, the status display, USB programming and a higher packet rate; the program is re-verified rather than re-written.
Where the project outgrows 2 MB, the migration inside the family is the 1756-L72 or L73 with the same wiring and the same chassis. A memory change is a controller swap plus a download, not a re-panel.
How much user memory does the 1756-L71 have?
2 MB of user memory and 0.98 MB of I/O memory, with published maximums of 128,000 digital I/O points and 4,000 analogue I/O points (1756-TD001, ControlLogix 5570 Standard and Conformal Coated Controllers).
Does the 1756-L71 use a battery?
No. It ships with the 1756-ESMCAP capacitor energy storage module already installed; the alternative 1756-ESMNSE removes the residual wall-clock backup so the stored energy depletes to 40 µJ or less before transport. The 1756-ESMNRM is the non-removable version used where the SD card must not be taken out.
What storage comes in the box?
A 1 GB Secure Digital card, catalogue 1784-SD1, ships pre-installed in the controller. Larger cards are listed in the memory card section of 1756-TD001.
What is the backplane current draw?
800 mA at 5.1 V DC and 5 mA at 1.2 V DC, dissipating 2.5 W and 8.5 BTU/hr (1756-TD001). The 800 mA is the number to add to a chassis budget before the I/O modules are counted.
Which port does a programming terminal use?
A USB port, with 30 V continuous basic isolation from the port to the system, compliant and tested to IEC/UL 61010-1. The port is for temporary local programming, configuration, firmware update and online edits, not for a permanent connection.
Can a 1756-L71 replace a 1756-L61?
It is the functional replacement path: same chassis, same slot width, same I/O. The program is re-verified because the firmware revision, the memory size and the programming port change, but the wiring and the module layout do not.
What does the status display show?
Firmware revision (Rev XX.xxx), the project name or No Project, TEST then PASS at power-up, CHRG while the energy storage module charges, SAVE/LOAD/UPDT while the SD card is being written or read, and BUSY while I/O modules are still powering up (1756-UM001).
Where can the 1756-L71 be installed?
In any slot of a 1756 chassis, one slot wide, in the 0…60 °C surrounding air the controller is rated for. The chassis supply must cover 800 mA at 5.1 V DC plus 5 mA at 1.2 V DC on top of every I/O module in the rack.
Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and the manufacturer's product page for 1756-L71. Values re-checked 16 November 2026.