logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IB32 / 1756IB32

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IB32 / 1756IB32

China Allen Bradley PLC 1756-IB32 / 1756IB32 supplier
Allen Bradley PLC 1756-IB32 / 1756IB32 supplier Allen Bradley PLC 1756-IB32 / 1756IB32 supplier Allen Bradley PLC 1756-IB32 / 1756IB32 supplier Allen Bradley PLC 1756-IB32 / 1756IB32 supplier Allen Bradley PLC 1756-IB32 / 1756IB32 supplier

Large Image :  Allen Bradley PLC 1756-IB32 / 1756IB32

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IB32 / 1756IB32

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $235.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IB32 technical data PDF download 1756-IB32 ControlLogix 32 Point DC Input Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IB32 (also written 1756IB32) is the 32-point sinking DC input module: one slot carrying twice the points of a 1756-IB16 for 5.5 mA per input and 120 mA at 5.1 V DC of backplane current (1756-IN062).

The trade is explicit. The IB16 draws 10 mA per input at 10...31.2 V DC; the IB32 draws 5.5 mA, so the input burden on the field circuit is lower, and the backplane cost is 120 mA for 32 points instead of 200 mA for two IB16 modules. Density in a single slot, at the price of one module boundary instead of two.

Isolation on the IB32 is 250 V continuous reinforced from inputs to backplane and 250 V basic between input groups, with no isolation between individual inputs in a group — the same arrangement as the IB16, so a panel mix of the two behaves consistently.

Published record: UPC 612598171309, active lifecycle, estimated lead time 5 days, country of origin multiple, one year warranty, description '10-31 VDC Input 32 Pts (36 Pin)' — the 36-pin terminal block is the housing class this module needs. Technical data 1756-TD002, user manual 1756-UM058, installation instructions 1756-IN062.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IB32
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 36-pin terminal block
 Mounting
 Chassis slot
 Number Of Channels
 32
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IB32 input module product photograph 1756-IB32 terminal side product photograph 1756-IB32 module view product photograph

Where the module sits in a typical system

The IB32 is the density choice: a machine with 30-plus sensors in one area gets one module instead of two, one terminal block instead of two, and one slot back in the chassis.

It suits marshalled panels where field wiring arrives on a terminal strip rather than direct to the module, because the 36-pin block then feeds from the marshalling rather than from individual device cables.

Where inputs must be isolated from one another — different field supplies, different machines — the IB32's group-level isolation is not enough, and the IB16I or separate groups are the correct answer.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  32 points on one commons arrangement  A single module carries four groups. A field fault in one group still leaves the module reporting, but the wiring plan has to respect the group boundaries.
 Check 3  Backplane saved, density gained  120 mA for 32 points against 200 mA for two IB16 modules — the saving matters in a full chassis.
 Check 4  Range identical to IB16  10...31.2 V DC. Density does not widen the input window.
 Check 5  Field wiring volume  Thirty-two pairs land on one block. Leave terminal space in the panel; the chassis width is unchanged but the wiring gutter is not.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The 16-point equivalent is 1756-IB16 with the same 10...31.2 V DC range, 10 mA input current and the same isolation arrangement at 100 mA backplane.

The diagnostic option is 1756-IB16D; the individually isolated option is 1756-IB16I. Neither exists as a 32-point module, so density and diagnostics are a choice.

The XT version for extended temperature is 1756-IB32XT, listed in the same module manual.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IB32 ControlLogix 32 Point DC Input Module | Rockwell

What is the 1756-IB32?

A 32-point sinking DC input module, 10...31.2 V DC, 5.5 mA maximum input current.

What is the backplane load?

120 mA at 5.1 V DC and 2 mA at 24 V DC (1756-IN062).

How does it compare with two 1756-IB16 modules?

It fits 32 points in one slot at 120 mA backplane instead of 200 mA across two modules, and needs one 36-pin terminal block instead of two 20-pin blocks.

What isolation does it have?

250 V reinforced inputs-to-backplane and 250 V basic between input groups, with no isolation between individual inputs in a group.

Which terminal block fits?

A 36-pin removable terminal block, ordered separately — the module description states 32 points on a 36-pin connector.

Can I mix IB16 and IB32 in one chassis?

Yes. The isolation arrangement is the same, so the wiring conventions carry across both.

Is there a diagnostic 32-point version?

No. Diagnostics are offered on the 16-point IB16D; density and diagnostics are separate choices.

What is the UPC?

612598171309.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IB32. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)