Product Details:
Payment & Shipping Terms:
|
2080-OW4I is a 4-point relay output plug-in the Bulletin 2080 Micro800 plug-in family. Four dry relay contacts that switch AC or DC field loads, which is what a panel needs when the load voltage is not the controller supply.
A plug-in module snaps into a slot on the controller itself, so the I/O count grows without adding a DIN rail footprint or an expansion bus module.
| 2080-IF2 | 2-channel analog input plug-in | IN STOCK |
| 2080-IF4 | 4-channel analog input plug-in | IN STOCK |
| 2080-OF2 | 2-channel analog output plug-in | IN STOCK |
| 2080-TC2 | 2-channel thermocouple plug-in | IN STOCK |
| 2080-RTD2 | 2-channel RTD plug-in | IN STOCK |
| 2080-TRIMPOT6 | 6-channel trimpot analog input | IN STOCK |
| 2080-OB4 | 4-point DC source output plug-in | IN STOCK |
| 2080-OV4 | 4-point DC sink output plug-in | IN STOCK |
| 2080-OW4I | 4-point relay output plug-in | IN STOCK |
| 2080-IQ4OV4 | 8-point combo, 4 in / 4 out sink | IN STOCK |
| 2080-IQ4OB4 | 8-point combo, 4 in / 4 out source | IN STOCK |
| 2080-SERIALISOL | isolated RS-232/RS-485 serial plug-in | IN STOCK |
| 2080-MOT-HSC | high-speed counter plug-in | IN STOCK |
| 2080-MEMBAK-RTC | memory backup with real-time clock | IN STOCK |
| 2080-USBADAPTER | Micro810 USB adapter | IN STOCK |
| 2080-LCD | Micro810 LCD display with keypad | IN STOCK |
| 2080-REMLCD | Micro820 remote LCD display | IN STOCK |
| 2080-PS120-240VAC | 120/240 V AC to 24 V DC power supply | IN STOCK |
Catalog number |
2080-OW4I |
Product type |
4-point relay output plug-in |
Channels / points |
4 outputs |
Signal |
AC/DC dry relay contacts |
Isolation |
Isolated contacts |
Resolution |
Not published |
Controller compatibility |
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810 |
Dimensions, H x W x D |
12-pin terminal block |
Temperature rating |
Per 2080-UM004 |
Lifecycle status |
Active |
UPC |
Not published |
Country of origin |
Not published |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-UM004 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2080-OW4I is a 4-point relay output plug-in the Bulletin 2080 Micro800 plug-in family. Four dry relay contacts that switch AC or DC field loads, which is what a panel needs when the load voltage is not the controller supply.
A plug-in module snaps into a slot on the controller itself, so the I/O count grows without adding a DIN rail footprint or an expansion bus module.
Channel count and signal type are fixed by the catalog number: 4 outputs, AC/DC dry relay contacts.
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810
The module is configured in Connected Components Workbench, not by a hardware switch, so the project file has to match the module that is physically fitted.
Micro810 controllers have no plug-in slots at all; the Micro810 accessories take the USB or display port instead.
Rockwell describes the module as providing dry contact relay closure outputs for switching a variety of AC and DC voltages to field loads.
Every plug-in this family is rated for the same panel environment, and the terminal block is the part that decides whether a swap is quick or not.
Isolation is Isolated contacts. Where that matters, it is stated per model rather than assumed for the whole family.
Rockwell lists this catalog number as Active.
Dimensions are 12-pin terminal block, rated ambient Per 2080-UM004.
UPC is Not published, country of origin Not published.
A used plug-in is only worth fitting if the terminal block and the retaining clips are intact; the clips are what holds the module against vibration.
Match the catalog number exactly. The family contains pairs that differ only in sink versus source output or isolation, and the front label is the only reliable identifier once the box is gone.
A relay output needs no load voltage from the module, so the field circuit is entirely the panel designer's choice.
What does 2080-OW4I do?
4-point relay output plug-in: 4 outputs, AC/DC dry relay contacts.
Which controllers accept 2080-OW4I?
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810
What is the resolution of 2080-OW4I?
Not published.
What are the dimensions of 2080-OW4I?
12-pin terminal block, rated Per 2080-UM004.
Is 2080-OW4I still available from Rockwell?
Rockwell lists it as Active.
This record is placed against the other six 2080 Micro800 records on this site: three 20-point LC20 controllers and four accessories. The two tables below separate the controllers, where the choice is electrical, from the accessories, where the choice is which controller the part fits - because those are two different questions and the catalog numbers do not distinguish them.
Controllers. Everything except the input mix and the output type is identical across the three.
| Catalog number | Inputs as printed | Outputs as printed | Lifecycle as printed |
| 2080-LC20-20AWBR | 12 in: 4-11 at 120 V AC, 0-3 at 24 V DC | 8 relay, 2 A at 240 V AC / 1 A at 24 V DC | Active |
| 2080-LC20-20QBBR | 12 in, 24 V DC sink/source | 8 source 24 V DC, 1 A per point at 30 C / 0.3 A at 65 C | Discontinued 5 December 2025, replacement 2080-L20E-20QBBR |
| 2080-LC20-20QWBR | 12 in, 24 V DC sink/source | 8 relay, 2 A at 240 V AC / 1 A at 24 V DC | Discontinued 5 December 2025, replacement 2080-L20E-20QWBR |
Accessories. The compatible-controller field is what separates these four; the product type does not.
| Catalog number | What the page says it is | Controllers the page lists | Controllers it excludes |
| 2080-LCD | display and keypad, 1.5 in display, also a backup memory module | Micro810 controllers | not stated for 820/830/850 |
| 2080-OW4I | 4-point relay output plug-in, isolated contacts | Micro820, Micro830, Micro850 plug-in slots | Micro810 |
| 2080-TRIMPOT6 | 6-channel trimpot analog input, screwdriver adjusted, non-isolated | Micro820, Micro830, Micro850 plug-in slots | Micro810 |
| 2080-USBADAPTER | USB programming connection, 1 USB port | Micro810 12-point controllers only | every other controller |
Where this record sits: it is a plug-in that adds four relay outputs to a slot, and its own page prints no current rating for those contacts at all - the Signals field says AC/DC dry relay contacts and the Isolation field says isolated contacts, and that is the whole electrical description. The 4 A or 2 A a buyer expects to read here is not on this page.
The accessory group divides along one line that has nothing to do with function: the two plug-ins work in Micro820, Micro830 and Micro850 slots and explicitly not in Micro810, the display is listed against Micro810, and the USB adapter is Micro810 12-point only. Four accessories, three different compatibility answers, on records whose product types all read like small options.
What these pages do not carry: no relay contact life in operations for either the controller relays or the 4-point plug-in, no input on-state current or threshold per point, no analog resolution for the trimpot and no display resolution, no consumption figure for any plug-in, and no contact rating at all for 2080-OW4I. The LCD record fills its dimensions field with a publication reference rather than a size, and the OW4I record fills its dimensions field with a terminal count, so the mechanical envelope of those two has to come from the publications named on the page rather than from the table.
A 4-point relay plug-in with no printed contact rating is a part you cannot size from its page: the controller records print 2 A at 240 V AC for their own relay outputs, and this plug-in prints neither amps nor volts. The one dimensional field on the page reads 12-pin terminal block, which is a terminal count in a dimensions field.
Source: the field tables printed on the seven 2080 records on this site, which cite 2080-UM001 for the controllers and 2080-UM004 / 2080-WD009 / 2080-WD001 for the accessories; the supply window, the 90 x 104 x 75 mm housing, the 0.38 kg weight, the -20 to 65 C rating, the 5.62 W and 8.5 W figures, the derating of 1 A at 30 C against 0.3 A at 65 C, and the three compatibility answers are quoted from the records that print them.
This part sits in the Allen-Bradley Micro and Nano systems category, with the other models and spare parts listed alongside it.