Product Details:
Payment & Shipping Terms:
|
2080-OW4I is a 4-point relay output plug-in in the Bulletin 2080 Micro800 plug-in family. Four dry relay contacts that switch AC or DC field loads, which is what a panel needs when the load voltage is not the controller supply.
A plug-in module snaps into a slot on the controller itself, so the I/O count grows without adding a DIN rail footprint or an expansion bus module.
| 2080-IF2 | 2-channel analog input plug-in | IN STOCK |
| 2080-IF4 | 4-channel analog input plug-in | IN STOCK |
| 2080-OF2 | 2-channel analog output plug-in | IN STOCK |
| 2080-TC2 | 2-channel thermocouple plug-in | IN STOCK |
| 2080-RTD2 | 2-channel RTD plug-in | IN STOCK |
| 2080-TRIMPOT6 | 6-channel trimpot analog input | IN STOCK |
| 2080-OB4 | 4-point DC source output plug-in | IN STOCK |
| 2080-OV4 | 4-point DC sink output plug-in | IN STOCK |
| 2080-OW4I | 4-point relay output plug-in | IN STOCK |
| 2080-IQ4OV4 | 8-point combo, 4 in / 4 out sink | IN STOCK |
| 2080-IQ4OB4 | 8-point combo, 4 in / 4 out source | IN STOCK |
| 2080-SERIALISOL | isolated RS-232/RS-485 serial plug-in | IN STOCK |
| 2080-MOT-HSC | high-speed counter plug-in | IN STOCK |
| 2080-MEMBAK-RTC | memory backup with real-time clock | IN STOCK |
| 2080-USBADAPTER | Micro810 USB adapter | IN STOCK |
| 2080-LCD | Micro810 LCD display with keypad | IN STOCK |
| 2080-REMLCD | Micro820 remote LCD display | IN STOCK |
| 2080-PS120-240VAC | 120/240 V AC to 24 V DC power supply | IN STOCK |
Catalog number |
2080-OW4I |
Product type |
4-point relay output plug-in |
Channels / points |
4 outputs |
Signal |
AC/DC dry relay contacts |
Isolation |
Isolated contacts |
Resolution |
Not published |
Controller compatibility |
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810 |
Dimensions, H x W x D |
12-pin terminal block |
Temperature rating |
Per 2080-UM004 |
Lifecycle status |
Active |
UPC |
Not published |
Country of origin |
Not published |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-UM004 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2080-OW4I is a 4-point relay output plug-in in the Bulletin 2080 Micro800 plug-in family. Four dry relay contacts that switch AC or DC field loads, which is what a panel needs when the load voltage is not the controller supply.
A plug-in module snaps into a slot on the controller itself, so the I/O count grows without adding a DIN rail footprint or an expansion bus module.
Channel count and signal type are fixed by the catalog number: 4 outputs, AC/DC dry relay contacts.
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810
The module is configured in Connected Components Workbench, not by a hardware switch, so the project file has to match the module that is physically fitted.
Micro810 controllers have no plug-in slots at all; the Micro810 accessories take the USB or display port instead.
Rockwell describes the module as providing dry contact relay closure outputs for switching a variety of AC and DC voltages to field loads.
Every plug-in in this family is rated for the same panel environment, and the terminal block is the part that decides whether a swap is quick or not.
Isolation is Isolated contacts. Where that matters, it is stated per model rather than assumed for the whole family.
Rockwell lists this catalog number as Active.
Dimensions are 12-pin terminal block, rated ambient Per 2080-UM004.
UPC is Not published, country of origin Not published.
A used plug-in is only worth fitting if the terminal block and the retaining clips are intact; the clips are what holds the module against vibration.
Match the catalog number exactly. The family contains pairs that differ only in sink versus source output or isolation, and the front label is the only reliable identifier once the box is gone.
A relay output needs no load voltage from the module, so the field circuit is entirely the panel designer's choice.
What does 2080-OW4I do?
4-point relay output plug-in: 4 outputs, AC/DC dry relay contacts.
Which controllers accept 2080-OW4I?
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810
What is the resolution of 2080-OW4I?
Not published.
What are the dimensions of 2080-OW4I?
12-pin terminal block, rated Per 2080-UM004.
Is 2080-OW4I still available from Rockwell?
Rockwell lists it as Active.