|
Product Details:
Payment & Shipping Terms:
|
The 2080-LC20-20AWBR is the same 20-point AC-input Micro820 as the 20AWB, built with removable terminal blocks.
Removable blocks matter on a machine that is serviced in the field: a controller can be swapped without rewiring, and the blocks travel with the harness.
| 2080-LC10-12AWA | Micro810, 8 AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QWB | Micro810, 8 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QBB | Micro810, 8 DC/AC in / 4 DC source out | IN STOCK |
| 2080-LC10-12DWD | Micro810, 8 12V DC in / 4 relay out | IN STOCK |
| 2080-LC20-20AWB | Micro820, 12 AC in / 8 relay out | IN STOCK |
| 2080-LC20-20QWB | Micro820, 12 DC in / 8 relay out | IN STOCK |
| 2080-LC20-20QBB | Micro820, 12 DC in / 8 DC source out | IN STOCK |
| 2080-LC20-20AWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QBBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC30-10QWB | Micro830, 6 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC30-10QVB | Micro830, 6 DC/AC in / 4 DC sink out | IN STOCK |
| 2080-LC30-16AWB | Micro830, 10 AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QWB | Micro830, 10 DC/AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QVB | Micro830, 10 DC/AC in / 6 DC sink out | IN STOCK |
| 2080-LC30-24QWB | Micro830, 14 DC/AC in / 10 relay out | IN STOCK |
| 2080-LC30-24QVB | Micro830, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC30-24QBB | Micro830, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC30-48AWB | Micro830, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QWB | Micro830, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QVB | Micro830, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-24AWB | Micro850, 14 AC in / 10 relay out | IN STOCK |
| 2080-LC50-24QVB | Micro850, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC50-24QBB | Micro850, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC50-48AWB | Micro850, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QWB | Micro850, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QVB | Micro850, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-48QBB | Micro850, 28 DC/AC in / 20 DC source out | IN STOCK |
Catalog number |
2080-LC20-20AWBR |
Family |
Micro820 20-point Ethernet controller |
I/O points |
20 (12 inputs, 8 relay outputs) |
Inputs |
12 inputs, 120 V AC on inputs 4 to 11; inputs 0 to 3 are 24 V DC |
Outputs |
8 relay outputs, 2 A at 240 V AC and 1 A at 24 V DC |
Supply |
24 V DC Class 2, 20.4 to 26.4 V DC |
Communication |
USB 2.0 (USB-C on the 2080-L20E), 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial, microSD slot for data logging and recipes |
Plug-in modules |
2 plug-in slots |
Dimensions, H x W x D |
90 x 104 x 75 mm |
Shipping weight |
0.38 kg |
Temperature rating |
-20 to 65 C (-4 to 149 F) |
Power consumption, max |
5.62 W without plug-ins, 8.5 W with |
Lifecycle |
Active |
Removable terminal blocks |
Removable terminal blocks |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-TD001 (module specifications) and 2080-TD001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 2080-LC20-20AWBR is the same 20-point AC-input Micro820 as the 20AWB, built with removable terminal blocks.
Everything else matches the 20AWB: Ethernet, serial, microSD and two plug-in slots.
The terminal blocks unplug, so the wiring schedule should be labelled per block rather than per controller.
Input circuit is 120 V AC on inputs 4 to 11; inputs 0 to 3 are 24 V DC.
Relay output rating is 2 A at 240 V AC and 1 A at 24 V DC.
Communication and capacity. USB 2.0 (USB-C on the 2080-L20E), 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial, microSD slot for data logging and recipes
2 plug-in slots plug-in modules can be fitted, each drawing about 1.44 W of the controller's internal budget.
Connected Components Workbench is the programming environment for the whole family, so a project built for one Micro800 controller converts to another with the I/O reassigned.
Mounting is DIN rail or panel, 90 x 104 x 75 mm, shipping 0.38 kg.
Rated ambient -20 to 65 C (-4 to 149 F), maximum consumption 5.62 W without plug-ins, 8.5 W with.
Lifecycle. Active
Twenty points, two plug-in slots, Ethernet and serial on the base unit.
Rockwell lists it as Active.
The R suffix is the whole difference from 2080-LC20-20AWB, and it is worth paying for on a machine that will be serviced.
How many I/O points does 2080-LC20-20AWBR have?
Micro820 20-point Ethernet controller: 20 (12 inputs, 8 relay outputs).
What is the input type on 2080-LC20-20AWBR?
12 inputs, 120 V AC on inputs 4 to 11; inputs 0 to 3 are 24 V DC.
What does 2080-LC20-20AWBR use for communication?
USB 2.0 (USB-C on the 2080-L20E), 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial, microSD slot for data logging and recipes.
What are the dimensions of 2080-LC20-20AWBR?
90 x 104 x 75 mm, 0.38 kg.
What is the lifecycle status of 2080-LC20-20AWBR?
Active.
This record is placed against the other six 2080 Micro800 records on this site: three 20-point LC20 controllers and four accessories. The two tables below separate the controllers, where the choice is electrical, from the accessories, where the choice is which controller the part fits - because those are two different questions and the catalog numbers do not distinguish them.
Controllers. Everything except the input mix and the output type is identical across the three.
| Catalog number | Inputs as printed | Outputs as printed | Lifecycle as printed |
| 2080-LC20-20AWBR | 12 in: 4-11 at 120 V AC, 0-3 at 24 V DC | 8 relay, 2 A at 240 V AC / 1 A at 24 V DC | Active |
| 2080-LC20-20QBBR | 12 in, 24 V DC sink/source | 8 source 24 V DC, 1 A per point at 30 C / 0.3 A at 65 C | Discontinued 5 December 2025, replacement 2080-L20E-20QBBR |
| 2080-LC20-20QWBR | 12 in, 24 V DC sink/source | 8 relay, 2 A at 240 V AC / 1 A at 24 V DC | Discontinued 5 December 2025, replacement 2080-L20E-20QWBR |
Accessories. The compatible-controller field is what separates these four; the product type does not.
| Catalog number | What the page says it is | Controllers the page lists | Controllers it excludes |
| 2080-LCD | display and keypad, 1.5 in display, also a backup memory module | Micro810 controllers | not stated for 820/830/850 |
| 2080-OW4I | 4-point relay output plug-in, isolated contacts | Micro820, Micro830, Micro850 plug-in slots | Micro810 |
| 2080-TRIMPOT6 | 6-channel trimpot analog input, screwdriver adjusted, non-isolated | Micro820, Micro830, Micro850 plug-in slots | Micro810 |
| 2080-USBADAPTER | USB programming connection, 1 USB port | Micro810 12-point controllers only | every other controller |
Where this record sits: it is the only record of the three LC20 controllers that is still Active, and the only one whose inputs are not all one voltage. Inputs 4 to 11 are printed as 120 V AC and inputs 0 to 3 as 24 V DC, so a panel wired on the assumption that twelve inputs take the same signal is wired wrong on four of them.
The three LC20 controllers share everything that is not the point type: the same 24 V DC Class 2 supply window of 20.4 to 26.4 V DC, the same 90 x 104 x 75 mm housing, the same 0.38 kg shipping weight, the same -20 to 65 C rating, the same two plug-in slots and the same 10/100 Base-T Ethernet and RS-232/RS-485 combo serial port. What changes between them is only the input voltage mix and the output type - which is exactly the two things a panel drawing has to get right, and exactly the two things the catalog suffix encodes.
What these pages do not carry: no relay contact life in operations for either the controller relays or the 4-point plug-in, no input on-state current or threshold per point, no analog resolution for the trimpot and no display resolution, no consumption figure for any plug-in, and no contact rating at all for 2080-OW4I. The LCD record fills its dimensions field with a publication reference rather than a size, and the OW4I record fills its dimensions field with a terminal count, so the mechanical envelope of those two has to come from the publications named on the page rather than from the table.
The split input is the whole reason to read this record twice: 120 V AC on eight points and 24 V DC on four means two terminal groupings, two field-wiring conventions and two sets of spare fuses in one catalog number, while the Q and W variants next to it take 24 V DC on all twelve.
Source: the field tables printed on the seven 2080 records on this site, which cite 2080-UM001 for the controllers and 2080-UM004 / 2080-WD009 / 2080-WD001 for the accessories; the supply window, the 90 x 104 x 75 mm housing, the 0.38 kg weight, the -20 to 65 C rating, the 5.62 W and 8.5 W figures, the derating of 1 A at 30 C against 0.3 A at 65 C, and the three compatibility answers are quoted from the records that print them.
Browse the Allen-Bradley Micro and Nano systems category for the other models, options and spare parts that share this range.