Product Details:
Payment & Shipping Terms:
|
The 2080-LC10-12QWB is the 24 V DC version of the 12-point Micro810, with the same four relay outputs as the AC-supplied model.
It suits panels that already run a 24 V DC bus: one supply feeds the controller and the field devices, and the relay outputs still switch AC loads.
| 2080-LC10-12AWA | Micro810, 8 AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QWB | Micro810, 8 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QBB | Micro810, 8 DC/AC in / 4 DC source out | IN STOCK |
| 2080-LC10-12DWD | Micro810, 8 12V DC in / 4 relay out | IN STOCK |
| 2080-LC20-20AWB | Micro820, 12 AC in / 8 relay out | IN STOCK |
| 2080-LC20-20QWB | Micro820, 12 DC in / 8 relay out | IN STOCK |
| 2080-LC20-20QBB | Micro820, 12 DC in / 8 DC source out | IN STOCK |
| 2080-LC20-20AWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QBBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC30-10QWB | Micro830, 6 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC30-10QVB | Micro830, 6 DC/AC in / 4 DC sink out | IN STOCK |
| 2080-LC30-16AWB | Micro830, 10 AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QWB | Micro830, 10 DC/AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QVB | Micro830, 10 DC/AC in / 6 DC sink out | IN STOCK |
| 2080-LC30-24QWB | Micro830, 14 DC/AC in / 10 relay out | IN STOCK |
| 2080-LC30-24QVB | Micro830, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC30-24QBB | Micro830, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC30-48AWB | Micro830, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QWB | Micro830, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QVB | Micro830, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-24AWB | Micro850, 14 AC in / 10 relay out | IN STOCK |
| 2080-LC50-24QVB | Micro850, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC50-24QBB | Micro850, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC50-48AWB | Micro850, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QWB | Micro850, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QVB | Micro850, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-48QBB | Micro850, 28 DC/AC in / 20 DC source out | IN STOCK |
Catalog number |
2080-LC10-12QWB |
Family |
Micro810 12-point smart relay controller |
I/O points |
12 (8 inputs, 4 relay outputs) |
Inputs |
8 inputs, 24 V DC or 24 V AC |
Outputs |
4 relay outputs, two rated 8 A and two rated 4 A |
Supply |
24 V DC Class 2, 20.4 to 26.4 V DC, 3 W maximum |
Communication |
USB 2.0 programming port through the 2080-USBADAPTER; no Ethernet or serial port |
Plug-in modules |
None; the Micro810 has no plug-in slots, only the LCD and USB accessories |
Dimensions, H x W x D |
91 x 75 x 59 mm |
Shipping weight |
0.203 kg |
Temperature rating |
0 to 55 C (32 to 131 F) |
Power consumption, max |
3 W |
Lifecycle |
Active |
Relay output rating |
Two outputs at 8 A, two at 4 A |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-TD001 (module specifications) and 2080-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 2080-LC10-12QWB is the 24 V DC version of the 12-point Micro810, with the same four relay outputs as the AC-supplied model.
It suits panels that already run a 24 V DC bus: one supply feeds the controller and the field devices, and the relay outputs still switch AC loads.
DC input models share four of the eight inputs as 0 to 10 V analog channels, which is how a Micro810 reads a pressure transducer without an analog module.
Supply range is 20.4 to 26.4 V DC, so the 24 V rail has to stay inside the Class 2 window.
Relay outputs are two at 8 A and two at 4 A; the current rating is per output, not per common.
Terminal torque is 0.5 to 0.6 Nm with a 0.6 x 3.5 mm screwdriver, and the terminals are fixed, not removable.
Communication and capacity. USB 2.0 programming port through the 2080-USBADAPTER; no Ethernet or serial port
None; the Micro810 has no plug-in slots, only the LCD and USB accessories plug-in modules can be fitted, each drawing about 1.44 W of the controller's internal budget.
Connected Components Workbench is the programming environment for the whole family, so a project built for one Micro800 controller converts to another with the I/O reassigned.
Mounting is DIN rail or panel, 91 x 75 x 59 mm, shipping 0.203 kg.
Rated ambient 0 to 55 C (32 to 131 F), maximum consumption 3 W.
Lifecycle. Active
Twelve points total, with no plug-in slots: the Micro810 accepts only the LCD and USB accessories.
Rockwell lists it as Active.
It is the model to fit where a 24 V DC panel needs a handful of relay outputs and a timer.
How many I/O points does 2080-LC10-12QWB have?
Micro810 12-point smart relay controller: 12 (8 inputs, 4 relay outputs).
What is the input type on 2080-LC10-12QWB?
8 inputs, 24 V DC or 24 V AC.
What does 2080-LC10-12QWB use for communication?
USB 2.0 programming port through the 2080-USBADAPTER; no Ethernet or serial port.
What are the dimensions of 2080-LC10-12QWB?
91 x 75 x 59 mm, 0.203 kg.
What is the lifecycle status of 2080-LC10-12QWB?
Active.
2080-LC10-12QWB is a 12 point Micro810 controller with 24V DC inputs and relay outputs in the Micro800 family, and the point table below is the published configuration for this catalog number rather than a family summary.
| Specification | Value |
|---|---|
| Catalog number | 2080-LC10-12QWB, Micro810 controller, 12 point, 24V DC input |
| Power | 24V DC |
| Inputs | 8 inputs at 24V DC |
| Outputs | 4 relay outputs |
| Analog inputs | 4 channels of 0 to 10V, shared with four of the DC inputs |
| Output rating | Two 8 A and two 4 A relay outputs |
| Form factor | 12 point, Micro810 |
| Programming | Connected Components Workbench, USB programming port, 1.5 in LCD and keypad for function block configuration |
| Source | 2080-SG001 Micro800 selection guide, Micro810 controllers input and output table |
Four of the eight DC inputs double as 0 to 10 volt analog inputs, which is how a twelve point controller offers any analog at all. The channels are shared, so the maximum is four analog and four digital, or eight digital and no analog.
A relay output with an eight amp rating is a maintenance-friendly choice for a load that cycles a few times a day, and a poor choice for one that cycles continuously. The same controller with source outputs exists for the second case, and the catalog suffix is the only difference on the drawing.
The point mix, the communication ports and the analog channel sharing on this page are taken from the Micro800 selection guide entry for this catalog number. Where a feature depends on a firmware revision, the row states the revision rather than implying it is universal.
The remote LCD module is a configuration aid, not an operator interface. It sets an IP address and shows a text display for a compact controller that has no screen, and its IP65 rating is the reason it can be mounted on the outside of an enclosure rather than behind the door.
A Micro800 controller is specified by the point mix rather than by the point count. Two catalogs with twenty points can carry eight AC inputs and seven relays, or twelve DC inputs and seven relays with an analog output, and the drawing that assumed the wrong mix has to be redone at the terminal level.
Expansion capacity is a hard number, not a suggestion. Micro850 controllers accept up to four expansion modules, and the 2085 family is the one that fits them, while the 2080 plug-in modules occupy the two plug-in slots on the compact models. Mixing the two kinds of expansion is a common ordering error.
Firmware revision gates features on these controllers. EtherNet/IP Class 1 connections to drives and remote LCD support arrive at specific revisions, and a controller from stock may predate them, so the revision belongs in the commissioning checklist rather than in the brochure.
Power supply choice follows from the input type, not from the output type. A controller with 120 to 240 volt AC inputs takes its field power from the same source that feeds the inputs, while a 24 volt DC input model needs a separate supply and puts that supply on the bill of materials.
The microSD slot is a maintenance feature more than a data feature. Project backup and restore from a card is what allows a service technician to replace a controller without a laptop and the original project file, and data logging and recipes are the secondary uses.
Conformal coating suffixes exist across the family for the same reason they exist elsewhere: condensing humidity, corrosive atmospheres and washdown areas. The suffix changes the materials, not the point mix, and the electrical ratings stay with the base catalog number.
Analog channels shared with digital inputs are a compromise worth understanding. Four 24 volt DC inputs can be configured as 0 to 10 volt analog inputs on the DC input models, which means the channel count is shared rather than added, and a machine that needs both cannot have both.
Plug-in modules and expansion modules are different form factors with different buses. A plug-in module sits in a slot inside the controller housing and shares its power, while an expansion module is a separate DIN rail device with its own terminal blocks, and the wiring effort differs accordingly.
The 2080 numbering carries the point mix in the suffix. AC input models are A, DC input models are Q, and the last letters describe the outputs: W for relay, V for sink, B for source. Reading the suffix is faster than opening the selection guide, and it is the same logic the family uses for expansion modules.
Communication ports on a small controller decide the architecture as much as the I/O does. An embedded Ethernet port with four Class 1 nodes is enough for a drive and a panel, and a serial port with Modbus RTU is enough for a weigh scale, but a machine that needs both protocols on multiple devices has outgrown the compact model.
A twelve point controller with relay outputs is a smart relay replacement, and the design intent is visible in the function blocks: delay on and off, time of day, time of week and time of year are built in rather than programmed, which is what a lighting or pump alternation panel needs.
Rated outputs are the reason these controllers exist in machine building. Two eight amp and two four amp relay outputs on the smallest model remove the external interposing relays for a small pump or a lamp, and the eight amp figure is per output with a total module limit that has to be read before the loads are added up.
Choose it where a 24 volt supply exists and analog is wanted on a twelve point budget, and accept the shared channel count.
The Allen-Bradley Micro and Nano systems category groups the other catalog numbers, options and spare parts in the same range.