The 2080-LC10-12AWA is the AC-supplied 12-point Micro810: eight 120/240 V AC inputs and four relay outputs that switch the load directly, so a small panel needs no interposing relays.
Rockwell positions the Micro810 as a smart relay with the programming capability of a micro PLC: delay ON/OFF timers, time of day, time of week and time of year function blocks are built in for lighting and timer work.
| 2080-LC10-12AWA | Micro810, 8 AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QWB | Micro810, 8 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QBB | Micro810, 8 DC/AC in / 4 DC source out | IN STOCK |
| 2080-LC10-12DWD | Micro810, 8 12V DC in / 4 relay out | IN STOCK |
| 2080-LC20-20AWB | Micro820, 12 AC in / 8 relay out | IN STOCK |
| 2080-LC20-20QWB | Micro820, 12 DC in / 8 relay out | IN STOCK |
| 2080-LC20-20QBB | Micro820, 12 DC in / 8 DC source out | IN STOCK |
| 2080-LC20-20AWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QBBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC30-10QWB | Micro830, 6 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC30-10QVB | Micro830, 6 DC/AC in / 4 DC sink out | IN STOCK |
| 2080-LC30-16AWB | Micro830, 10 AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QWB | Micro830, 10 DC/AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QVB | Micro830, 10 DC/AC in / 6 DC sink out | IN STOCK |
| 2080-LC30-24QWB | Micro830, 14 DC/AC in / 10 relay out | IN STOCK |
| 2080-LC30-24QVB | Micro830, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC30-24QBB | Micro830, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC30-48AWB | Micro830, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QWB | Micro830, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QVB | Micro830, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-24AWB | Micro850, 14 AC in / 10 relay out | IN STOCK |
| 2080-LC50-24QVB | Micro850, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC50-24QBB | Micro850, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC50-48AWB | Micro850, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QWB | Micro850, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QVB | Micro850, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-48QBB | Micro850, 28 DC/AC in / 20 DC source out | IN STOCK |
Catalog number |
2080-LC10-12AWA |
Family |
Micro810 12-point smart relay controller |
I/O points |
12 (8 inputs, 4 relay outputs) |
Inputs |
8 inputs, 120/240 V AC; four of them can be reconfigured as 0 to 10 V analog inputs |
Outputs |
4 relay outputs, two rated 8 A and two rated 4 A |
Supply |
100 to 240 V AC, 50/60 Hz, 85 to 263 V range, 5 VA maximum |
Communication |
USB 2.0 programming port through the 2080-USBADAPTER; no Ethernet or serial port |
Plug-in modules |
None; the Micro810 has no plug-in slots, only the LCD and USB accessories |
Dimensions, H x W x D |
91 x 75 x 59 mm |
Shipping weight |
0.203 kg |
Temperature rating |
0 to 55 C (32 to 131 F) |
Power consumption, max |
5 VA |
Lifecycle |
Active |
Relay output rating |
Two outputs at 8 A, two at 4 A |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-TD001 (module specifications) and 2080-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 2080-LC10-12AWA is the AC-supplied 12-point Micro810: eight 120/240 V AC inputs and four relay outputs that switch the load directly, so a small panel needs no interposing relays.
It is the controller to specify when the machine is a pump, a fan, a gate or a lighting circuit rather than a motion axis.
Inputs and outputs are on fixed screw terminals with 7 mm stripping length and 0.5 to 0.6 Nm torque.
The relay contacts are the reason this model exists: 8 A and 4 A ratings mean a contactor coil or a small heater can be wired straight to the controller.
Four of the eight inputs are analog/digital configurable, so a 0 to 10 V sensor can share the same terminal strip as the discrete switches.
Communication and capacity. USB 2.0 programming port through the 2080-USBADAPTER; no Ethernet or serial port
None; the Micro810 has no plug-in slots, only the LCD and USB accessories plug-in modules can be fitted, each drawing about 1.44 W of the controller's internal budget.
Connected Components Workbench is the programming environment for the whole family, so a project built for one Micro800 controller converts to another with the I/O reassigned.
Mounting is DIN rail or panel, 91 x 75 x 59 mm, shipping 0.203 kg.
Rated ambient 0 to 55 C (32 to 131 F), maximum consumption 5 VA.
Lifecycle. Active
Eight inputs and four outputs is the whole I/O count: there is no expansion and no plug-in slot, so the application has to fit in twelve points.
The USB programming port is reached through the 2080-USBADAPTER, and the 2080-LCD gives local configuration without a PC.
Rockwell lists it as Active, and it is still the cheapest way into the Micro800 programming environment.
How many I/O points does 2080-LC10-12AWA have?
Micro810 12-point smart relay controller: 12 (8 inputs, 4 relay outputs).
What is the input type on 2080-LC10-12AWA?
8 inputs, 120/240 V AC; four of them can be reconfigured as 0 to 10 V analog inputs.
What does 2080-LC10-12AWA use for communication?
USB 2.0 programming port through the 2080-USBADAPTER; no Ethernet or serial port.
What are the dimensions of 2080-LC10-12AWA?
91 x 75 x 59 mm, 0.203 kg.
What is the lifecycle status of 2080-LC10-12AWA?
Active.
2080-LC10-12AWA is a 12 point Micro810 controller with AC inputs and relay outputs in the Micro800 family, and the point table below is the published configuration for this catalog number rather than a family summary.
| Specification | Value |
|---|---|
| Catalog number | 2080-LC10-12AWA, Micro810 controller, 12 point, AC input |
| Power | 120 to 240V AC |
| Inputs | 8 inputs at 120/240V AC |
| Outputs | 4 relay outputs |
| Output rating | Two 8 A and two 4 A relay outputs, enough to switch small loads without external relays |
| Analog channels | None on the AC input model |
| Form factor | 12 point, Micro810 |
| Programming | Connected Components Workbench, USB programming port; smart relay function blocks configurable from the 1.5 in LCD and keypad |
| Built in function blocks | Delay off and on timer, time of day, time of week, time of year |
| Source | 2080-SG001 Micro800 selection guide, Micro810 controllers input and output table |
Eight AC inputs and four relays is the whole I/O of this controller, and the two eight amp outputs are the feature that makes it a smart relay replacement. A pump of a few horsepower can be switched directly, which removes a contactor and its panel space from a small machine.
The absence of analog channels on the AC input model is a real configuration difference, not a rounding. A machine that needs a 0 to 10 volt transducer has to move to the DC input model, and the decision is made at the point mix rather than at the price.
The point mix, the communication ports and the analog channel sharing on this page are taken from the Micro800 selection guide entry for this catalog number. Where a feature depends on a firmware revision, the row states the revision rather than implying it is universal.
Expansion capacity is a hard number, not a suggestion. Micro850 controllers accept up to four expansion modules, and the 2085 family is the one that fits them, while the 2080 plug-in modules occupy the two plug-in slots on the compact models. Mixing the two kinds of expansion is a common ordering error.
Firmware revision gates features on these controllers. EtherNet/IP Class 1 connections to drives and remote LCD support arrive at specific revisions, and a controller from stock may predate them, so the revision belongs in the commissioning checklist rather than in the brochure.
Power supply choice follows from the input type, not from the output type. A controller with 120 to 240 volt AC inputs takes its field power from the same source that feeds the inputs, while a 24 volt DC input model needs a separate supply and puts that supply on the bill of materials.
The microSD slot is a maintenance feature more than a data feature. Project backup and restore from a card is what allows a service technician to replace a controller without a laptop and the original project file, and data logging and recipes are the secondary uses.
Conformal coating suffixes exist across the family for the same reason they exist elsewhere: condensing humidity, corrosive atmospheres and washdown areas. The suffix changes the materials, not the point mix, and the electrical ratings stay with the base catalog number.
Analog channels shared with digital inputs are a compromise worth understanding. Four 24 volt DC inputs can be configured as 0 to 10 volt analog inputs on the DC input models, which means the channel count is shared rather than added, and a machine that needs both cannot have both.
Plug-in modules and expansion modules are different form factors with different buses. A plug-in module sits in a slot inside the controller housing and shares its power, while an expansion module is a separate DIN rail device with its own terminal blocks, and the wiring effort differs accordingly.
The 2080 numbering carries the point mix in the suffix. AC input models are A, DC input models are Q, and the last letters describe the outputs: W for relay, V for sink, B for source. Reading the suffix is faster than opening the selection guide, and it is the same logic the family uses for expansion modules.
Communication ports on a small controller decide the architecture as much as the I/O does. An embedded Ethernet port with four Class 1 nodes is enough for a drive and a panel, and a serial port with Modbus RTU is enough for a weigh scale, but a machine that needs both protocols on multiple devices has outgrown the compact model.
A twelve point controller with relay outputs is a smart relay replacement, and the design intent is visible in the function blocks: delay on and off, time of day, time of week and time of year are built in rather than programmed, which is what a lighting or pump alternation panel needs.
Rated outputs are the reason these controllers exist in machine building. Two eight amp and two four amp relay outputs on the smallest model remove the external interposing relays for a small pump or a lamp, and the eight amp figure is per output with a total module limit that has to be read before the loads are added up.
The remote LCD module is a configuration aid, not an operator interface. It sets an IP address and shows a text display for a compact controller that has no screen, and its IP65 rating is the reason it can be mounted on the outside of an enclosure rather than behind the door.
A Micro800 controller is specified by the point mix rather than by the point count. Two catalogs with twenty points can carry eight AC inputs and seven relays, or twelve DC inputs and seven relays with an analog output, and the drawing that assumed the wrong mix has to be redone at the terminal level.
Choose it where the panel is AC throughout, the loads are relays, and no analog signal is needed.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley Micro and Nano systems category.