Product Details:
Payment & Shipping Terms:
|
2085-IRT4 is a 4-channel temperature input module in the Micro800 expansion line. It reads RTDs and thermocouples directly at 16 bits, which removes four transmitters and their loop supplies from a temperature panel.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
| 2085-IA8 | 8-point 120 V AC input | IN STOCK |
| 2085-IM8 | 8-point 240 V AC input | IN STOCK |
| 2085-OA8 | 8-point 120/240 V AC triac output | IN STOCK |
| 2085-IQ32T | 32-point 12/24 V DC sink/source input | IN STOCK |
| 2085-OV16 | 16-point 12/24 V DC sink transistor output | IN STOCK |
| 2085-OB16 | 16-point 12/24 V DC source transistor output | IN STOCK |
| 2085-OW8 | 8-point AC/DC relay output | IN STOCK |
| 2085-OW16 | 16-point AC/DC relay output, 2 A | IN STOCK |
| 2085-IF4 | 4-channel 14-bit isolated analog input | IN STOCK |
| 2085-IF8 | 8-channel 14-bit isolated analog input | IN STOCK |
| 2085-OF4 | 4-channel 12-bit isolated analog output | IN STOCK |
| 2085-IRT4 | 4-channel 16-bit RTD and thermocouple input | IN STOCK |
| 2085-ECR | 2085 expansion bus terminator | IN STOCK |
Catalog number |
2085-IRT4 |
Product type |
4-channel temperature input module |
Points / channels |
4 channels |
Signal |
RTD and thermocouple, 16-bit |
Isolation |
Isolated, field wiring to controller |
Backplane current, 5 V DC |
Not published |
Dimensions, H x W x D |
Not published |
Temperature rating |
Not published |
Lifecycle status |
Active |
UPC |
Not published |
Country of origin |
Not published |
Terminal block |
Removable terminal block (RTB) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-UM003 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2085-IRT4 is a 4-channel temperature input module in the Micro800 expansion line. It reads RTDs and thermocouples directly at 16 bits, which removes four transmitters and their loop supplies from a temperature panel.
It mounts to the right of a Micro810, Micro820, Micro830, Micro850 or Micro870 controller and is addressed by its position in the expansion chain, so the slot order in the project has to match the physical order.
Signal and channel count are fixed by the catalog number: 4 channels, RTD and thermocouple, 16-bit.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
Sensor type is selected in software per channel, so the same card covers a Pt100 and a type J thermocouple on neighbouring zones.
Size the conductors and the torque to the module data sheet; the RTB screws are hand-tightened, not driven with a power tool.
Module order matters: the expansion chain is scanned in physical order, and the bus is ended with a terminator. Isolation is field to controller, not channel to channel, which matters when the sensors sit at different potentials.
Backplane draw is Not published. Add every module in the chain before deciding on the controller power budget.
Rockwell lists this catalog number as Active.
Dimensions are Not published and the rated ambient is Not published.
UPC is Not published, country of origin Not published.
Check that the module comes with its RTB. A module sold without the terminal block is not a drop-in swap, whatever the price difference.
Confirm the catalog number against the project: the 2085 line separates sink from source transistor outputs and AC input from DC input by catalog number only.
A temperature card is only as good as its cold junction and its wiring: check the terminal block for corrosion before trusting a used unit.
What does 2085-IRT4 do?
4-channel temperature input module: 4 channels, RTD and thermocouple, 16-bit.
Where does 2085-IRT4 mount?
To the right of a Micro800 controller, in the expansion chain, connected through the 2085 bus.
How much backplane current does 2085-IRT4 draw?
Not published.
What are the dimensions of 2085-IRT4?
Not published, rated Not published.
Is 2085-IRT4 a current Rockwell product?
Rockwell lists it as Active.