Product Details:
Payment & Shipping Terms:
|
2080-PS120-240VAC is a Power supply in the Bulletin 2080 Micro800 plug-in family. It is the DIN rail supply Rockwell provides for Micro800 controllers: 100 to 240 V AC in, 24 V DC at 1.6 A out.
A plug-in module snaps into a slot on the controller itself, so the I/O count grows without adding a DIN rail footprint or an expansion bus module.
| 2080-IF2 | 2-channel analog input plug-in | IN STOCK |
| 2080-IF4 | 4-channel analog input plug-in | IN STOCK |
| 2080-OF2 | 2-channel analog output plug-in | IN STOCK |
| 2080-TC2 | 2-channel thermocouple plug-in | IN STOCK |
| 2080-RTD2 | 2-channel RTD plug-in | IN STOCK |
| 2080-TRIMPOT6 | 6-channel trimpot analog input | IN STOCK |
| 2080-OB4 | 4-point DC source output plug-in | IN STOCK |
| 2080-OV4 | 4-point DC sink output plug-in | IN STOCK |
| 2080-OW4I | 4-point relay output plug-in | IN STOCK |
| 2080-IQ4OV4 | 8-point combo, 4 in / 4 out sink | IN STOCK |
| 2080-IQ4OB4 | 8-point combo, 4 in / 4 out source | IN STOCK |
| 2080-SERIALISOL | isolated RS-232/RS-485 serial plug-in | IN STOCK |
| 2080-MOT-HSC | high-speed counter plug-in | IN STOCK |
| 2080-MEMBAK-RTC | memory backup with real-time clock | IN STOCK |
| 2080-USBADAPTER | Micro810 USB adapter | IN STOCK |
| 2080-LCD | Micro810 LCD display with keypad | IN STOCK |
| 2080-REMLCD | Micro820 remote LCD display | IN STOCK |
| 2080-PS120-240VAC | 120/240 V AC to 24 V DC power supply | IN STOCK |
Catalog number |
2080-PS120-240VAC |
Product type |
Power supply |
Channels / points |
Not applicable |
Signal |
100-240 V AC input, 24 V DC 1.6 A output |
Isolation |
Reinforced, primary to secondary |
Resolution |
Not published |
Controller compatibility |
Micro800 controllers and expansion I/O |
Dimensions, H x W x D |
90 x 45 x 80 mm |
Temperature rating |
Per 2080-IN001 |
Lifecycle status |
Active |
UPC |
885630058382 |
Country of origin |
Thailand |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-IN001 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2080-PS120-240VAC is a Power supply in the Bulletin 2080 Micro800 plug-in family. It is the DIN rail supply Rockwell provides for Micro800 controllers: 100 to 240 V AC in, 24 V DC at 1.6 A out.
A plug-in module snaps into a slot on the controller itself, so the I/O count grows without adding a DIN rail footprint or an expansion bus module.
Channel count and signal type are fixed by the catalog number: Not applicable, 100-240 V AC input, 24 V DC 1.6 A output.
Micro800 controllers and expansion I/O
The module is configured in Connected Components Workbench, not by a hardware switch, so the project file has to match the module that is physically fitted.
Micro810 controllers have no plug-in slots at all; the Micro810 accessories take the USB or display port instead.
Output rating is 24 V DC at 1.6 A, 38.4 W maximum. Inrush is 24 A at 132 V and 40 A at 263 V for 10 ms. Enclosure rating IP20, weight about 0.34 kg.
Every plug-in this family is rated for the same panel environment, and the terminal block is the part that decides whether a swap is quick or not.
Isolation is Reinforced, primary to secondary. Where that matters, it is stated per model rather than assumed for the whole family.
Rockwell lists this catalog number as Active.
Dimensions are 90 x 45 x 80 mm, rated ambient Per 2080-IN001.
UPC is 885630058382, country of origin Thailand.
A used plug-in is only worth fitting if the terminal block and the retaining clips are intact; the clips are what holds the module against vibration.
Match the catalog number exactly. The family contains pairs that differ only in sink versus source output or isolation, and the front label is the only reliable identifier once the box is gone.
At 38.4 W it will not carry a large relay bank: add up the 24 V load before assuming one supply is enough.
What does 2080-PS120-240VAC do?
Power supply: Not applicable, 100-240 V AC input, 24 V DC 1.6 A output.
Which controllers accept 2080-PS120-240VAC?
Micro800 controllers and expansion I/O
What is the resolution of 2080-PS120-240VAC?
Not published.
What are the dimensions of 2080-PS120-240VAC?
90 x 45 x 80 mm, rated Per 2080-IN001.
Is 2080-PS120-240VAC still available from Rockwell?
Rockwell lists it as Active.
2080-PS120-240VAC is a 24V DC power supply, 1.6 A output in the Micro800 system, and the specification rows below are the published data for this catalog number.
| Specification | Value |
|---|---|
| Catalog number | 2080-PS120-240VAC, 24V DC power supply for Micro800 systems |
| Supply voltage range | 100 to 120V AC at 1 A, or 200 to 240V AC at 0.5 A |
| Supply frequency | 47 to 63 Hz |
| Supply power output | 24V DC, 1.6 A |
| Inrush current | 24 A at 132V for 10 ms; 40 A at 263V for 10 ms |
| Comparison with the 2080-PSAC-12W | The smaller supply accepts 100 to 120V AC at 0.7 A or 200 to 240V AC at 0.4 A, and delivers 24V DC at 0.9 A up to 50 degrees C and 0.5 A at 65 degrees C |
| Source | 2080-TD001 Micro800 technical data, power supply specifications |
One point six amps at twenty four volts is the budget for a controller, its plug-in modules and its expansion chain. A Micro850 published at thirty three watts with expansion needs most of that supply, which leaves little for field devices.
The inrush figure of forty amps at 263 volts for ten milliseconds is the number that decides the upstream breaker characteristic. A supply with a soft start input still draws that peak, and a fast breaker will trip on a cold start rather than on a fault.
The ranges, the currents and the filter time on this page are the published values for this catalog number, and the IEC type classification is quoted as published rather than interpreted.
The Type 1 input designation is a real classification, not marketing. IEC Type 1 inputs are the slow, tolerant sensors, and a module published against that standard is the right choice for a limit switch and the wrong one for a registration mark.
Channel update time on a temperature module is measured per enabled channel, not per module. Twelve to five hundred milliseconds per channel means a module with all channels enabled updates slowly, and a control loop that assumes a fast scan will be wrong about when the value arrived.
An expansion module is a separate DIN rail device with its own terminal block, and that changes the wiring effort compared with a plug-in module. The 2085 family is what a Micro850 chassis accepts, up to four of them, and each one carries its own field terminals rather than borrowing the controller row.
Relay and transistor outputs on the same family look interchangeable on a drawing and are not interchangeable on a load. A relay at eight amps per module handles an inrush that a transistor output rated half an amp per point will not survive, and the load type decides which module is ordered.
Two hundred and twenty grams of shipping weight and an open style enclosure are the practical statements about these modules. They are panel mounted inside an enclosure, they are not field mounted, and the enclosure rating is the panel rating rather than the module rating.
Isolation on these modules is fifty volts continuous, reinforced insulation, channel to system, with a type test at seven hundred and fifteen volts DC for sixty seconds. That is a working isolation for a panel with a common reference, not a barrier for a hazardous area, and the two should not be confused.
Analog temperature modules carry an accuracy that depends on the sensor type. A thermocouple input specified within half a degree to three degrees and an RTD input within two tenths to six tenths of a degree are two very different measurement systems sharing one module.
Expansion modules share the controller supply and add to its consumption, so the power budget is cumulative. A controller published at eleven watts with no expansion and thirty three watts with plug-ins and expansion is telling the designer that the difference belongs to the modules that were added.
Forty four and a half millimetres of width is the physical unit of expansion planning. Five modules fit in a fraction of the rail space that five separate controllers would take, and the depth of eighty seven millimetres is what decides whether the panel is deep enough for the terminal cover.
The bus terminator is the part that makes the serial expansion bus electrically correct. It terminates the end of the chain, it is listed in the same technical data as the modules, and a chain without it is a chain that may work on the bench and fail in the panel.
The point count on an expansion module is a bus load as well as a field count. Sixteen discrete inputs draw one hundred and seventy milliamps from the five volt bus and thirty two draw one hundred and ninety, which is the figure the controller power budget has to absorb for every module in the chain.
Derating curves are published for a reason, and they are the part of a data sheet that gets skipped. A sixteen point DC input module with a published curve will carry its full count at one ambient and a reduced count at another, and the cabinet temperature is the variable that decides which.
A green health indicator and no channel indicators is a deliberate diagnostic style on some analog modules. The module tells you it is alive and the channel value tells you the rest, which means the troubleshooting tool is the programming software rather than a lamp.
Check the 1.6 A output against the controller plus expansion draw, and check the 40 A inrush against the breaker curve before the panel is powered.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley Micro and Nano systems category.