Allen Bradley PLC 1785-M100 / 1785M100

China Allen Bradley PLC 1785-M100 / 1785M100 supplier
Allen Bradley PLC 1785-M100 / 1785M100 supplier Allen Bradley PLC 1785-M100 / 1785M100 supplier Allen Bradley PLC 1785-M100 / 1785M100 supplier Allen Bradley PLC 1785-M100 / 1785M100 supplier Allen Bradley PLC 1785-M100 / 1785M100 supplier

Large Image :  Allen Bradley PLC 1785-M100 / 1785M100

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply with 1 year warranty!
Model Number: Allen Bradley PLC 1785-M100 / 1785M100

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1015.00 (USD/PCS)
Packaging Details: 100% New packaging
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1785-M100 technical data PDF download 1785-M100 Rockwell PLC-5 100 K Word Memory Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: Bulletin 1785 · PLC-5 controllers, memory and accessories

1785-M100 is the 100 K word memory module of the PLC-5 family, the largest capacity Rockwell listed in this form.

The module seats in the controller's memory cartridge position; the processor battery backs the RAM it carries.

1785-ACC5LA PLC-5 accessory kit IN STOCK
1785-ACC5LB PLC-5 accessory kit IN STOCK
1785-CHBM ControlNet backup cartridge IN STOCK
1785-ENET PLC-5 Ethernet interface module IN STOCK
1785-L26B PLC-5/26 protected processor, 16 K words IN STOCK
1785-L40C15 PLC-5 ControlNet 1.5 processor, 48 K words IN STOCK
1785-L40C PLC-5 ControlNet 1.25 processor, 48 K words IN STOCK
1785-L46C15 PLC-5/46C ControlNet 1.5 protected processor IN STOCK
1785-L40E PLC-5/40E Ethernet processor, 48 K words IN STOCK
1785-L60B PLC-5/60 processor, 64 K words IN STOCK
1785-L60L PLC-5/60L processor with extended local I/O IN STOCK
1785-L80C PLC-5 ControlNet 1.25 processor, 100 K words IN STOCK
1785-L80B PLC-5/80 processor, 100 K words IN STOCK
1785-L80C15 PLC-5 ControlNet 1.5 processor, 100 K words IN STOCK
1785-L80E PLC-5/80E Ethernet processor, 100 K words IN STOCK
1785-L86B PLC-5/86 protected processor, 100 K words IN STOCK
1785-M100 100 K word memory module IN STOCK
1785-ME16 16 K word EEPROM memory cartridge IN STOCK
1785-ME32 32 K word EEPROM memory cartridge IN STOCK
1785-ME64 64 K word EEPROM memory cartridge IN STOCK
1785-RC Relay cartridge, edit and force monitoring IN STOCK

Product Specifications 1785-M100 (PDF)
 Catalog number
 1785-M100
 Product type
 PLC-5 memory module
 Storage capacity
 100 K words
 Lifecycle status
 Discontinued
 Discontinued date
 31 December 2012
 Replacement category
 Engineering Replacement
 UPC
 Not published
 Country of origin
 Not published

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see the Rockwell literature library and the module-specific publication named in the technical data section above.

1785-M100 1785-M100

ControlNet or DH+ channels and memory

1785-M100 is the 100 K word memory module of the PLC-5 family, the largest capacity Rockwell listed in this form.

It is a plug-in module: the controller recognises the fitted card type in status word 68, which is how a programmer tells a 100 K module from a 64 K one without opening the case.

Installing it in a PLC-5 chassis

The module seats in the controller's memory cartridge position; the processor battery backs the RAM it carries.

Fitting a module of a different size changes the memory available to the program file, so the project has to be re-sized before the module is swapped, not after.

Lifecycle and replacement

Rockwell lists 1785-M100 as Discontinued as of 31 December 2012, with Engineering Replacement as the category.

There is no modern memory cartridge that fits a PLC-5, so a used module is the only way to keep memory capacity on an existing processor.

Where these are still in use

These modules are bought to keep an existing PLC-5 alive after a memory fault, or to raise capacity on a processor that is being asked to carry a slightly larger program.

Because the module is passive, most of the risk sits in how it was stored: unseated pins and bent edge connectors are the usual defects.

Buying a used unit

Ask for the module in its anti-static packaging, and check the edge connector for bent or lifted pins before inserting it in a live controller.

Confirm the capacity marking on the label matches 100 K: a 64 K module fitted where a 100 K one is expected will simply show less memory, and that is easy to misread as a faulty processor.

FAQ — 1785-M100

What capacity is 1785-M100?

100 K words.

Is 1785-M100 still available new?

No. Rockwell lists it as Discontinued since 31 December 2012.

How does the controller identify the module?

The installed card type is reported in status word 68.

Can I fit a 1785-M100 to any PLC-5?

Only to controllers that accept a memory module of this form and support the capacity; check the processor's published memory option first.

What usually fails on a used module?

Bent edge connector pins and poor contact after long storage.


Data sources. Memory, I/O and channel figures come from the PLC-5 system specification table in 1785-UM012; lifecycle dates and UPC codes come from the Rockwell product page for the catalog number. Anything neither source prints is marked Not published. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1785-M100: PLC-5 EEPROM memory module, 100 K words

1785-M100 is the PLC-5 EEPROM memory module, 100 K words in the PLC-5 support and interface group. Memory cards back up the program, the relay cartridge provides a hardwired contact, and the sidecar puts a DH+ controller onto Ethernet.

AttributeValue
Catalog number1785-M100
Product typePLC-5 EEPROM memory module, 100 K words
FamilyPLC-5, bulletin 1785
TypeEEPROM memory card for the memory module slot
Capacity100 K words in the 1785-UM012 listing, printed as 1785-ME100
Status codeS:68 reports 4 when the 100 K card is installed
Fits controllers with102,400 words of user memory, that is the PLC-5/80 and PLC-5/80E class
Data table64 K words of data table space, 56 K words per program file, 32 K words per data table file
Load ruleUser memory on the target must be at least the memory used on the source
Cross familyControlNet and non ControlNet cards cannot be loaded across
Source1785-UM012D-EN-P, Enhanced and Ethernet PLC-5 controllers

One hundred thousand words is the largest card in the family and only the PLC-5/80 class has the user memory to take it. The catalog number printed on the store listing for this page is 1785-M100, while 1785-UM012 documents the 100 K card as 1785-ME100, so the label on the card and the packing list should be checked before the part is ordered as a spare.

Three facts from 1785-UM012D set the boundary for this part: the card slot reports its contents in S:68, the loading rules are set by user memory and I/O racks rather than by the card alone, and ControlNet and non ControlNet cards never cross.

The published controller limits that decide whether this part is the right one are 8,192 words on the PLC-5/11, 16,384 on the PLC-5/20, 32,768 on the PLC-5/30, 65,536 on the PLC-5/40 and 102,400 on the PLC-5/80, with a rack ceiling of 4, 4, 8, 16 and 24 respectively.

The memory module goes into the slot marked on the controller, and the module is keyed so that it seats in one orientation only. On a live panel the card is fitted with the chassis powered down, because the controller reads the card type at power up and a hot insertion leaves the status word reporting the previous device.

Rack numbering is octal and the range depends on the model: 00 to 03 on the PLC-5/11, PLC-5/20 and PLC-5/20E, 00 to 07 on the PLC-5/30, 00 to 17 on the PLC-5/40, PLC-5/40L and PLC-5/40E, and 00 to 27 on the PLC-5/60, PLC-5/60L, PLC-5/80 and PLC-5/80E. A 32-point module consumes rack numbers as the adapter allocates the remaining groups.

The user memory figures behind that rule are 8,192 words on the PLC-5/11, 16,384 on the PLC-5/20, 32,768 on the PLC-5/30, 65,536 on the PLC-5/40 and 102,400 on the PLC-5/80. Those are the numbers to compare against the program size before a card is carried from one machine to another as a quick fix.

The controller reports what is in the slot through S:68. Code 0 means no card, 1 is 1785-ME16, 2 is 1785-ME32, 3 is 1785-ME64, 4 is the 100 K card, 5 is 1785-CHBM and 6 is 1785-RC. Codes 7 to 15 are reserved, so an unexpected value is a fault indication rather than an unknown card.

Multihop messaging is the feature that lets a PLC-5 reach a ControlLogix processor through a 1756-ENET module and out through a 1756-DHRIO. It requires a series E revision D controller or later and a series B or later sidecar, plus RSLogix 5 release 3.2 or later, and the routing table in the DHRIO is configured from the Gateway software.

The restore path has one behaviour worth writing into the maintenance procedure. If the controller memory is bad, restoring from the card also sets the controller date and time to the date and time that were saved with the card. If the controller memory is still valid, the current date and time are kept. A historian that timestamps events will show the difference.

The battery behind all of this is the 1770-XYC, which contains 0.65 grams of lithium. On the PLC-5/11, PLC-5/20 and PLC-5/20E the published life is 256 days at 60 degrees C with the power off 100 percent of the time and 1.4 years at 50 percent, or 2 years and 4 years at 25 degrees C. The larger processors are shorter: 84 and 150 days at 60 degrees C, 1 year and 1.2 years at 25 degrees C.

Ethernet on this generation is 10 Mbps and the physical layer is whatever 802.3 media the site already has: thick wire 10Base5, thin wire 10Base2, twisted pair 10Base-T, fiber or broadband. The controller port is a 15-pin AUI connector, so the media choice is made by the transceiver rather than by the controller.

The programming port on these controllers is channel 0, a 25-pin D-shell serial port that supports RS-232C and RS-423 and is RS-422A compatible. Its pin assignment is printed on the side label of the controller, and the RS-422A use assumes no termination resistors with the distance and rate reduced to RS-423 limits.

ControlNet is a hard boundary. A card burned on a ControlNet PLC-5 cannot be loaded to a non ControlNet controller, and a card burned on a non ControlNet controller cannot be loaded to a ControlNet PLC-5. The two families look identical at the card slot, so this rule is the one that ruins a weekend if it is missed.

Two fault codes cover the card itself. Code 82 means an illegal cartridge type for the selected operation and also appears when the controller has no memory module at all, and code 85 means the memory module is bad. A successful upload sets S:1/10, which is the bit to check after a save rather than the programmer screen.

A DH+ channel and a remote I/O channel are the same physical port on these controllers, and the three pin ports are configured for remote I/O scanner, remote I/O adapter or DH+ communication. Changing that configuration after commissioning changes the addresses of everything downstream, so the mode belongs in the as built drawing.

Compatibility is defined twice, once by user memory and once by I/O memory. The card will load if the target controller has at least the user memory that was in use when the card was burned, and if its I/O memory is at least that of the controller the card came from. The rack counts are 4 for PLC-5/11 and PLC-5/20, 8 for PLC-5/30, 16 for PLC-5/40 and 24 for PLC-5/60 and PLC-5/80.

After the battery indicator first lights, the remaining life is measured in days rather than months: 11.5 days at 60 degrees C and 47 days at 25 degrees C on the small processors, 5 days and 30 days on the PLC-5/30 and above. A maintenance schedule built on months will therefore miss the window on a large controller.

The transceiver catalogue is small and specific: 1785-TR10BT for twisted pair, 1785-TR10BF for optical, 1785-TR10B2 for thin wire and 1785-TR10B5 for thick wire, with the 5810 series thin and thick wire parts as the older equivalents. Transceiver cables come in 2.0 m and 15.0 m lengths, and the kits pair a transceiver with one of those cables.

Before ordering any memory or interface part for a PLC-5, confirm the processor catalog number, the series and firmware revision, and check the label on the card itself against the catalog number on the drawing before the part is fitted.

The Allen-Bradley PLC-5 systems and 1771 I/O category lists the related catalog numbers, options and accessories for this range.