logo
Home ProductsAB PLC-5 Systems

Allen Bradley PLC 1785-RC / 1785RC

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1785-RC / 1785RC

China Allen Bradley PLC 1785-RC / 1785RC supplier
Allen Bradley PLC 1785-RC / 1785RC supplier Allen Bradley PLC 1785-RC / 1785RC supplier Allen Bradley PLC 1785-RC / 1785RC supplier Allen Bradley PLC 1785-RC / 1785RC supplier Allen Bradley PLC 1785-RC / 1785RC supplier

Large Image :  Allen Bradley PLC 1785-RC / 1785RC

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply with 1 year warranty!
Model Number: Allen Bradley PLC 1785-RC / 1785RC

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $915.00 (USD/PCS)
Packaging Details: 100% New packaging
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1785-RC technical data PDF download 1785-RC Rockwell PLC-5 Relay Cartridge for Edit and Force Monitoring

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: Bulletin 1785 · PLC-5 controllers, memory and accessories

1785-RC is a relay cartridge that sits in the PLC-5 processor and gives an external circuit a volt-free contact that opens whenever the controller detects a program edit or an I/O force request.

Installation is covered by 1785-IN001. The cartridge seats in the processor mating connector with the keying pins down, and the user supplies 120 V AC which the internal relay switches.

1785-ACC5LA PLC-5 accessory kit IN STOCK
1785-ACC5LB PLC-5 accessory kit IN STOCK
1785-CHBM ControlNet backup cartridge IN STOCK
1785-ENET PLC-5 Ethernet interface module IN STOCK
1785-L26B PLC-5/26 protected processor, 16 K words IN STOCK
1785-L40C15 PLC-5 ControlNet 1.5 processor, 48 K words IN STOCK
1785-L40C PLC-5 ControlNet 1.25 processor, 48 K words IN STOCK
1785-L46C15 PLC-5/46C ControlNet 1.5 protected processor IN STOCK
1785-L40E PLC-5/40E Ethernet processor, 48 K words IN STOCK
1785-L60B PLC-5/60 processor, 64 K words IN STOCK
1785-L60L PLC-5/60L processor with extended local I/O IN STOCK
1785-L80C PLC-5 ControlNet 1.25 processor, 100 K words IN STOCK
1785-L80B PLC-5/80 processor, 100 K words IN STOCK
1785-L80C15 PLC-5 ControlNet 1.5 processor, 100 K words IN STOCK
1785-L80E PLC-5/80E Ethernet processor, 100 K words IN STOCK
1785-L86B PLC-5/86 protected processor, 100 K words IN STOCK
1785-M100 100 K word memory module IN STOCK
1785-ME16 16 K word EEPROM memory cartridge IN STOCK
1785-ME32 32 K word EEPROM memory cartridge IN STOCK
1785-ME64 64 K word EEPROM memory cartridge IN STOCK
1785-RC Relay cartridge, edit and force monitoring IN STOCK

Product Specifications 1785-RC (PDF)
 Catalog number
 1785-RC
 Product type
 PLC-5 relay cartridge
 Function
 Edit and force monitoring relay
 Compatible controllers
 PLC-5/40B, PLC-5/60B, PLC-5/80B
 Firmware requirement
 Series E, revision E
 External supply
 120 V AC, supplied by the user
 Lifecycle status
 Discontinued
 Discontinued date
 Not published
 Replacement category
 Not published
 UPC
 Not published
 Country of origin
 Not published

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1785-IN001 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1785-RC 1785-RC

ControlNet or DH+ channels and memory

1785-RC is a relay cartridge that sits in the PLC-5 processor and gives an external circuit a volt-free contact that opens whenever the controller detects a program edit or an I/O force request.

It exists for regulated processes: the contact drives an external device such as a 700P relay, so a change to the running program leaves a physical trace outside the controller.

Installing it in a PLC-5 chassis

Installation is covered by 1785-IN001. The cartridge seats in the processor mating connector with the keying pins down, and the user supplies 120 V AC which the internal relay switches.

It is compatible with the PLC-5/40B, /60B and /80B controllers and requires Series E, revision E firmware; a lower firmware revision will not provide the status bits.

Lifecycle and replacement

The cartridge is no longer an orderable PLC-5 item. Rockwell's product records used here do not print a discontinued date for it, so none is quoted.

Four status bits report the cartridge state: external 120 V AC present, relay driven open, contact state, and cartridge installed.

Where these are still in use

These cartridges are bought by plants with validation obligations that still run a PLC-5: pharmaceutical, food and specialty chemical lines where an edit must be visible outside the controller.

When one fails, the replacement search is usually urgent, because the validation record depends on the function being present.

Buying a used unit

Confirm the controller model is one of the three supported, and that the processor firmware is at Series E, revision E, before expecting the status bits to work.

Ask for the cartridge to be tested in a compatible processor, and check the connector for bent pins.

FAQ — 1785-RC

What does 1785-RC do?

It opens a relay contact when a program edit or I/O force request is detected.

Which controllers support it?

PLC-5/40B, /60B and /80B, per 1785-IN001.

What firmware is required?

Series E, revision E.

Does it need external power?

Yes, the user supplies 120 V AC for the switched circuit.

What should I check before buying?

Controller compatibility, firmware revision and connector condition.


Data sources. Function, compatibility and firmware requirement come from 1785-IN001. Rockwell prints no lifecycle date or UPC for this cartridge in the records used here. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1785-RC: PLC-5 relay cartridge

1785-RC is the PLC-5 relay cartridge in the PLC-5 support and interface group. Memory cards back up the program, the relay cartridge provides a hardwired contact, and the sidecar puts a DH+ controller onto Ethernet.

AttributeValue
Catalog number1785-RC
Product typePLC-5 relay cartridge
FamilyPLC-5, bulletin 1785
FunctionInterface from the controller to a user supplied external device such as an Allen-Bradley 700P relay
BehaviourWhile in run mode the controller monitors online ladder edits and I/O forcing, and opens the relay for one second when either is detected
Status codeS:68 reports 6 when this cartridge is installed
Status bitsBit 3 set when installed, bit 2 when contact detected closed, bit 1 when relay driven open, bit 0 when 120V ac present
PositionOccupies the controller memory card slot
Supported byEthernet PLC-5 controllers, per the additional information section of 1785-UM012D
WiringCustomer supplied relay circuit, the module only provides the contact
Source1785-UM012D-EN-P, Enhanced and Ethernet PLC-5 controllers

The relay cartridge is not a memory device even though it sits in the memory slot, and the status word treats it differently: the eight least significant bits of S:68 carry the cartridge state rather than a size code. That one second opening on an online edit or a forcing change is the whole function, and it is the reason the part exists on a machine where an edit during production has to drop a hardwired permissive.

Three facts from 1785-UM012D set the boundary for this part: the card slot reports its contents in S:68, the loading rules are set by user memory and I/O racks rather than by the card alone, and ControlNet and non ControlNet cards never cross.

The published controller limits that decide whether this part is the right one are 8,192 words on the PLC-5/11, 16,384 on the PLC-5/20, 32,768 on the PLC-5/30, 65,536 on the PLC-5/40 and 102,400 on the PLC-5/80, with a rack ceiling of 4, 4, 8, 16 and 24 respectively.

An EEPROM card is a program backup device, not extra working memory. The program is saved to the card from the programming software while the controller runs, and the card is then loaded back into controller memory after a battery failure or a memory fault. Nothing executes from the card, so the controller user memory still decides what program size is possible.

Firmware is the second boundary. A card saved on a series D revision B controller cannot be loaded to a controller with earlier firmware, and the same applies to cards saved on series E revision A and series E revision B. Older cards move forward freely, newer cards do not move back.

The memory module goes into the slot marked on the controller, and the module is keyed so that it seats in one orientation only. On a live panel the card is fitted with the chassis powered down, because the controller reads the card type at power up and a hot insertion leaves the status word reporting the previous device.

Rack numbering is octal and the range depends on the model: 00 to 03 on the PLC-5/11, PLC-5/20 and PLC-5/20E, 00 to 07 on the PLC-5/30, 00 to 17 on the PLC-5/40, PLC-5/40L and PLC-5/40E, and 00 to 27 on the PLC-5/60, PLC-5/60L, PLC-5/80 and PLC-5/80E. A 32-point module consumes rack numbers as the adapter allocates the remaining groups.

The user memory figures behind that rule are 8,192 words on the PLC-5/11, 16,384 on the PLC-5/20, 32,768 on the PLC-5/30, 65,536 on the PLC-5/40 and 102,400 on the PLC-5/80. Those are the numbers to compare against the program size before a card is carried from one machine to another as a quick fix.

The controller reports what is in the slot through S:68. Code 0 means no card, 1 is 1785-ME16, 2 is 1785-ME32, 3 is 1785-ME64, 4 is the 100 K card, 5 is 1785-CHBM and 6 is 1785-RC. Codes 7 to 15 are reserved, so an unexpected value is a fault indication rather than an unknown card.

Multihop messaging is the feature that lets a PLC-5 reach a ControlLogix processor through a 1756-ENET module and out through a 1756-DHRIO. It requires a series E revision D controller or later and a series B or later sidecar, plus RSLogix 5 release 3.2 or later, and the routing table in the DHRIO is configured from the Gateway software.

The restore path has one behaviour worth writing into the maintenance procedure. If the controller memory is bad, restoring from the card also sets the controller date and time to the date and time that were saved with the card. If the controller memory is still valid, the current date and time are kept. A historian that timestamps events will show the difference.

The battery behind all of this is the 1770-XYC, which contains 0.65 grams of lithium. On the PLC-5/11, PLC-5/20 and PLC-5/20E the published life is 256 days at 60 degrees C with the power off 100 percent of the time and 1.4 years at 50 percent, or 2 years and 4 years at 25 degrees C. The larger processors are shorter: 84 and 150 days at 60 degrees C, 1 year and 1.2 years at 25 degrees C.

Ethernet on this generation is 10 Mbps and the physical layer is whatever 802.3 media the site already has: thick wire 10Base5, thin wire 10Base2, twisted pair 10Base-T, fiber or broadband. The controller port is a 15-pin AUI connector, so the media choice is made by the transceiver rather than by the controller.

The programming port on these controllers is channel 0, a 25-pin D-shell serial port that supports RS-232C and RS-423 and is RS-422A compatible. Its pin assignment is printed on the side label of the controller, and the RS-422A use assumes no termination resistors with the distance and rate reduced to RS-423 limits.

ControlNet is a hard boundary. A card burned on a ControlNet PLC-5 cannot be loaded to a non ControlNet controller, and a card burned on a non ControlNet controller cannot be loaded to a ControlNet PLC-5. The two families look identical at the card slot, so this rule is the one that ruins a weekend if it is missed.

Two fault codes cover the card itself. Code 82 means an illegal cartridge type for the selected operation and also appears when the controller has no memory module at all, and code 85 means the memory module is bad. A successful upload sets S:1/10, which is the bit to check after a save rather than the programmer screen.

A DH+ channel and a remote I/O channel are the same physical port on these controllers, and the three pin ports are configured for remote I/O scanner, remote I/O adapter or DH+ communication. Changing that configuration after commissioning changes the addresses of everything downstream, so the mode belongs in the as built drawing.

Compatibility is defined twice, once by user memory and once by I/O memory. The card will load if the target controller has at least the user memory that was in use when the card was burned, and if its I/O memory is at least that of the controller the card came from. The rack counts are 4 for PLC-5/11 and PLC-5/20, 8 for PLC-5/30, 16 for PLC-5/40 and 24 for PLC-5/60 and PLC-5/80.

Before ordering any memory or interface part for a PLC-5, confirm the processor catalog number, the series and firmware revision, and check the label on the card itself against the catalog number on the drawing before the part is fitted.

The Allen-Bradley PLC-5 systems and 1771 I/O category groups the other catalog numbers, options and spare parts in the same range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)