The 1794-OB8 is the eight-point 24V DC sourcing output module of FLEX I/O: eight outputs sharing one external supply, a 0.5V maximum drop at 500 mA, and no internal fusing.
It suits small islands that drive pilot lights, small solenoid valves or annunciators where eight outputs are enough and the load stays inside 4 A per module.
| 1794-OB8 | 8-point 24V DC sourcing output module | IN STOCK |
| 1794-OB8EP | 8-point 2 A electronically fused sourcing output module | IN STOCK |
| 1794-OB16 | 16-point 24V DC sourcing output module | IN STOCK |
| 1794-OB16P | 16-point protected sourcing output module | IN STOCK |
| 1794-OB16D | 16-point diagnostic 24V DC output module | IN STOCK |
| 1794-OB32P | 32-point protected sourcing output module | IN STOCK |
| 1794-OB16PXT | 16-point protected sourcing output, extended temperature | IN STOCK |
| 1794-OB8EPXT | 8-point 2 A electronically fused output, extended temperature | IN STOCK |
| 1794-OV16 | 16-point sinking output module | IN STOCK |
| 1794-OV16P | 16-point protected sinking output module | IN STOCK |
| 1794-OV32 | 32-point sinking output module | IN STOCK |
| 1794-OC16 | 16-point 48V DC sourcing output module | IN STOCK |
| 1794-OG16 | 16-point 5V DC sourcing output module | IN STOCK |
| 1794-OW8 | 8-point isolated relay output module | IN STOCK |
Application |
FLEX I/O digital output, 1794 terminal base |
Cat Num |
1794-OB8 |
Brand Name |
Rockwell |
Outputs |
8, current, sourcing |
On-state voltage |
10V DC min, 24V DC nom, 31.2V DC max |
Output current |
500 mA per channel, 4 A per module |
On-state voltage drop |
0.5V DC max |
Off-state leakage |
0.5 mA max |
Surge current |
2 A for 50 ms, repeatable every 2 s |
Output delay |
0.5 ms off to on, 1.0 ms on to off |
Isolation |
50V continuous; tested 850V DC for 1 s, I/O to system |
Power dissipation |
3.3 W max at 31.2V DC (11.2 BTU/hr) |
Terminal base |
1794-TB2, -TB3, -TB3S, -TB3K, -TB3SK |
Fusing |
Not fused; SAN-O M04-800 mA external fuse |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Eight sourcing outputs over 10...31.2V DC, 500 mA per channel and 4 A per module, with 1.0 mA minimum load per channel.
0.5V DC maximum drop at rated current and 0.5 mA maximum off-state leakage — the leakage figure is what decides whether a two-wire input on the same circuit reads the output as off.
2 A surge for 50 ms every 2 s covers a lamp filament or a small solenoid inrush without tripping the output.
A 4 A module ceiling is reached with eight channels at 500 mA, so an island using all eight at full load has no headroom for a later function.
The 5% ripple allowance belongs to the supply range; a rectified 24V rail without filtering can exceed it and make an output chatter.
Fusing at the load protects the field wiring, fusing on the base protects the module and its output stage — different jobs, often both needed.
Row B carries the outputs on a TB3 base and row C the load supply, with the return taken from the module common.
With no isolation between channels, a ground fault on one output can pull the common of the whole group, which is the argument for a fuse per channel.
The external supply is 10...31.2V DC with 5% ripple and draws 10...35 mA from the field supply for its own logic, separate from the load current.
50V continuous basic insulation, tested at 850V DC for 1 s between field side and system, with no isolation between channels.
3.3 W maximum dissipation at 31.2V DC (11.2 BTU/hr) is the heat the enclosure removes at full load.
The outputs are not fused internally. Rockwell specifies a SAN-O M04-800 mA fuse per output, fitted in the panel or on a fused terminal base.
A shorted solenoid without that fuse takes the module out rather than the fuse — the reason the note is repeated in every FLEX I/O publication.
For fused termination, the 1794-TBNF series base mounts the fuses on the terminal base, which keeps the fuse adjacent to the field wiring.
Any of 1794-TB2, -TB3, -TB3S, -TB3K or -TB3SK carries the module; the suffix selects screw, spring or cage clamp and the knife-disconnect variant.
Outputs land on row B with the load supply on row C, and the return is common to the module's output stage.
Delay of 0.5 ms off to on and 1.0 ms on to off is fast enough for a valve, slow enough to be irrelevant to a scan.
Small islands. With an 8-point output module beside a 1794-IB8 the island stays compact and the spare strategy stays cheap.
Annunciators and lamps. 500 mA per channel covers a stack light directly, without an interposing relay.
Not for starting contactors. A 4 A module limit and a 2 A surge do not pull in a large contactor coil; that is a 1794-OB8EP case.
How many outputs has the 1794-OB8?
Eight, current sourcing, 500 mA per channel and 4 A per module maximum.
Does it need external fusing?
Yes. The outputs are not fused internally; Rockwell specifies a SAN-O M04-800 mA fuse.
What is the output voltage range?
10...31.2V DC, nominal 24V DC, with a 5% AC ripple allowance on the field supply.
How much does it dissipate?
3.3 W maximum at 31.2V DC, equal to 11.2 BTU/hr.
Which terminal bases are supported?
1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K and 1794-TB3SK.
What is the isolation rating?
50V continuous, type tested at 850V DC for 1 s between field side and system; no channel-to-channel isolation.