Product Details:
Payment & Shipping Terms:
|
The 1794-TB3SK is the conformally coated, spring clamp version of the 1794-TB3: 16 I/O, 18 common and 18 +V terminals.
Two changes from the standard base — spring termination and the K coating — and both pay off where a panel is either vibration-prone or cold enough to condense.
| 1794-TB2 | 16-terminal cage clamp base, 2-wire, up to 132V AC | IN STOCK |
| 1794-TB3 | 16-terminal cage clamp base, 3-wire devices | IN STOCK |
| 1794-TB3S | 16-terminal spring clamp base, 3-wire devices | IN STOCK |
| 1794-TB32 | 32-terminal cage clamp base for 32-point modules | IN STOCK |
| 1794-TB32S | 32-terminal spring clamp base for 32-point modules | IN STOCK |
| 1794-TB3T | temperature base with two cold junction compensation sets | IN STOCK |
| 1794-TB3TS | spring clamp temperature base with CJC sets | IN STOCK |
| 1794-TB3G | grounded screw clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TB3GS | grounded spring clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TBKD | cage clamp base with 16 knife disconnects | IN STOCK |
| 1794-TBN | NEMA-style screw clamp base, up to 264V AC/DC | IN STOCK |
| 1794-TBNF | fused NEMA-style base, eight 5 x 20 mm fuses | IN STOCK |
| 1794-TB37DS | 37-pin D-shell termination for digital and analog modules | IN STOCK |
| 1794-TB62DS | 62-pin D-shell termination for digital and analog modules | IN STOCK |
Application |
FLEX I/O 3-wire terminal base |
Cat Num |
1794-TB3SK |
Brand Name |
Rockwell |
Termination |
Spring clamp, 16 I/O, 18 common, 18 +V |
Wire size |
0.34...3.3 mm2 (22...12 AWG), 75 deg C or greater |
Current capacity |
10 A maximum |
Voltage |
Module dependent |
Wiring category |
1 |
Dimensions |
94 x 94 x 69 mm |
Operating temperature |
-20...70 deg C |
Coating |
Conformal |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
16 I/O, 18 common, 18 +V — the full 3-wire pattern, so every point can source a proximity switch.
Spring clamp termination gives the faster, simpler wire installation the guide describes for the TB3S.
10 A current capacity with the 22...12 AWG wire window of the spring family.
-20...70 deg C operating range on a 94 x 94 x 69 mm base.
The K suffix marks the conformally coated catalog in the selection guide, used with -XT modules.
Coating protects the base, the modules need their own -XT versions — a coated base under an uncoated module is a partial fix.
Rail layout does not change; the footprint matches the uncoated 1794-TB3S.
Field wiring practice is unchanged; the coating covers the assembly, not the terminals.
3-wire input proximity switches in a cold or condensing cabinet.
High-vibration mounting where spring termination holds better than a screw.
Not for 2-wire devices without spare +V — the 1794-TB2 is the narrower, cheaper choice.
Not a temperature base; thermocouple islands need the 1794-TB3TSK.
35 x 7.5 mm DIN rail with at least 25 mm of air space around the system.
Zinc-plated, yellow-chromated steel rail for grounding through the rail.
1794-NM1 panel kit where no rail is used, with star-washer screws.
1492-EA35 rail locks for vertical or high-vibration installs.
Coated digital islands built with -XT input modules.
Outdoor cabinets where condensation forms at start-up.
Not a general purpose base; the uncoated 1794-TB3S costs less indoors.
Not for 32-point cards; the 1794-TB32SK is the coated 32-point spring base.
What does the 1794-TB3SK add over the 1794-TB3S?
Conformal coating; terminals and ratings are the same.
How many +V terminals does it have?
18, the full 3-wire pattern.
What is the current capacity?
10 A maximum.
What wire size does it accept?
0.34...3.3 mm2 (22...12 AWG), 75 deg C or greater.
What is the operating temperature?
-20...70 deg C.
Which modules pair with it?
The -XT module family; a coated base alone does not make an uncoated module suited to the environment.