Product Details:
Payment & Shipping Terms:
|
The 1794-TB3K is the conformally coated cage-clamp terminal base: 16 I/O terminals, 18 common and 18 +V, rated 10 A and -20...70 deg C.
The K suffix is the coating, and it is what pairs this base with the -XT extended-temperature modules on the same rail.
| 1794-TB2 | 16-terminal cage clamp base, 2-wire, up to 132V AC | IN STOCK |
| 1794-TB3 | 16-terminal cage clamp base, 3-wire devices | IN STOCK |
| 1794-TB3S | 16-terminal spring clamp base, 3-wire devices | IN STOCK |
| 1794-TB32 | 32-terminal cage clamp base for 32-point modules | IN STOCK |
| 1794-TB32S | 32-terminal spring clamp base for 32-point modules | IN STOCK |
| 1794-TB3T | temperature base with two cold junction compensation sets | IN STOCK |
| 1794-TB3TS | spring clamp temperature base with CJC sets | IN STOCK |
| 1794-TB3G | grounded screw clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TB3GS | grounded spring clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TBKD | cage clamp base with 16 knife disconnects | IN STOCK |
| 1794-TBN | NEMA-style screw clamp base, up to 264V AC/DC | IN STOCK |
| 1794-TBNF | fused NEMA-style base, eight 5 x 20 mm fuses | IN STOCK |
| 1794-TB37DS | 37-pin D-shell termination for digital and analog modules | IN STOCK |
| 1794-TB62DS | 62-pin D-shell termination for digital and analog modules | IN STOCK |
Application |
FLEX I/O terminal base, 1794 backplane |
Cat Num |
1794-TB3K |
Brand Name |
Rockwell |
Termination |
Cage clamp, 16 I/O, 18 common, 18 +V |
Wire size |
0.34...3.3 mm2 (22...12 AWG), 75 deg C or greater, 1.2 mm insulation max |
Current capacity |
10 A maximum |
Voltage |
Up to 132V AC / 156V DC |
Wiring category |
2 |
Dimensions |
94 x 94 x 69 mm |
Operating temperature |
-20...70 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
16 I/O, 18 common and 18 +V terminals in a cage clamp, so each field wire is held by a screw-driven clamp rather than a spring.
10 A maximum current capacity across the base, which is the number to check against a 16-point output card's total load.
24...12 AWG accepted, with 1.2 mm maximum insulation diameter.
Up to 132V AC / 156V DC on the terminals, and wiring category 2 for the routing plan.
Conformal coating is the only difference between the 1794-TB3K and the 1794-TB3.
-20...70 deg C operating range matches the XT modules, so a cold panel keeps one temperature statement across the base and the card.
94 x 94 x 69 mm is identical to the uncoated base, so the rail length and enclosure depth do not change.
The base plugs to the next base and forms the backplane; no separate wiring between bases is required.
The general-purpose 1794 base, described in the selection guide as intended for 3-wire input proximity switches and usable with output modules.
Three-wire sensors use the +V and common terminals, which is why the base carries 18 of each rather than a single pair.
Not the choice for temperature modules, which need the CJC sets of the 1794-TB3T.
Not the choice for 32-point cards, which need the 1794-TB32 terminal count.
35 x 7.5 mm DIN rail (Allen-Bradley 199-DR1, DIN 46277-3) with at least 25 mm of air space around the system.
A zinc-plated, yellow-chromated steel rail is required for grounding through the rail; aluminium or plastic rail gives intermittent grounding.
1794-NM1 panel-mount kit with 18 screws replaces the rail where direct mounting is needed.
1492-EA35 DIN rail locks are recommended in high-vibration or vertical installations.
Extended-temperature islands where every base should match the -XT cards.
Panels with condensation that the coating is specified for.
Not for thermocouples; the 1794-TB3T provides the two CJC sets.
Not for 32-point modules; use the 1794-TB32 or 1794-TB32S.
What does the K suffix mean on the 1794-TB3K?
It is the conformally coated version of the 1794-TB3 base.
How many terminals has it?
16 I/O, 18 common and 18 +V, in a cage clamp.
What current can it carry?
10 A maximum, with 24...12 AWG wire.
What is the operating temperature?
-20...70 deg C.
Does it need separate backplane wiring?
No, bases plug together to form the backplane.
What rail does it mount on?
35 x 7.5 mm DIN rail, or panel mount with the 1794-NM1 kit.
1794-TB3K is a FLEX I/O terminal base unit, not an I/O module. It is the part that carries the field terminals, plugs into the adjacent base to form the backplane, and holds the module on top. The termination type here is Cage clamp with 16 I/O, 18 common, 18 +V.
| Attribute | Value |
| Catalog number | 1794-TB3K |
| Termination type | Cage clamp |
| Connections | 16 I/O, 18 common, 18 +V |
| Current capacity, maximum | 10 A |
| Wiring category | module dependent |
| Field voltage | Same field range as the 1794-TB3 |
| Operating temperature | -20...+70 C |
| Purpose in the range | The 1794-TB3 supplied with a conformal coating for corrosive or condensation-prone locations. |
The conductor range for this base is 0.34 to 3.3 mm2 (22 to 12 AWG) solid or stranded copper rated 75 C or greater, with 1.2 mm maximum insulation, with a maximum current capacity of 10 A across the base. Those figures are the base rating and not the module rating: a 16 point module on a 10 A base is still limited by the module output current per channel.
Selecting a base is a compatibility step, not a preference step. The module data sheet names the bases that are permitted for it, and a base outside that list may key differently, may not carry the required common and voltage terminals, or may not be rated for the field voltage of the module.
The wiring category matters as much as the gauge: category 2 bases are the general field wiring class, while grounded bases in the 1794-TB3G family carry 10 chassis ground terminals for analog and temperature modules where a separate signal common is needed.
For a retrofit into an existing slice, the addressing is decided by position rather than by catalog number: FLEX I/O assigns the module its place in the rack by the order of the bases on the rail, so inserting a module in the middle shifts the addresses of everything to its right and requires the program to be re-checked.
FLEX I/O bases and modules are separate line items on a purchase order, and the price of getting that wrong is a second shipment: a module without its base cannot be installed, and a base of the wrong termination type cannot be reworked in the field because the module keys to the base family.
The 22 to 12 AWG acceptance range on the standard bases is wider than the field device terminals in most panels, so the practical constraint is usually the device end, not the base end. Where a 24V DC sensor cable is 18 AWG and the base accepts 12 AWG, the conductor still has to be torqued to the published value rather than to feel.
Conformal coating on a K suffix base is applied to the assembled board and not to the terminals, so the coating protects the electronics against condensation while the field terminals remain serviceable. That is the point of ordering the coated base instead of sealing the whole enclosure.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.