Product Details:
Payment & Shipping Terms:
|
The 1794-ID2 counts two channels at up to 100 kHz with A, B, Z and gate inputs per channel, a 2 ms minimum pulse width, and a 304.8 m cable allowance on Belden 8761.
It sits between the frequency module and the very high speed counter: faster than a digital input with a timer, slower than a registration card, and with the gate input a batch application expects.
| 1794-IJ2 | 2-channel frequency input module, 1...32 kHz | IN STOCK |
| 1794-IJ2XT | 2-channel frequency input module, extended temperature | IN STOCK |
| 1794-VHSC | 2-axis very high speed counter, 1 MHz, 8 compare windows | IN STOCK |
| 1794-ID2 | 2-channel counter with A, B, Z and gate inputs | IN STOCK |
| 1794-IP4 | 4-channel counter module, 100 kHz | IN STOCK |
Application |
FLEX I/O counter, 1794 terminal base |
Cat Num |
1794-ID2 |
Brand Name |
Rockwell |
Channels |
2 counter channels |
Inputs per channel |
A, B, Z and gate |
Frequency |
100 kHz |
Minimum pulse width |
2 ms |
Cable |
Belden 8761 or equivalent, 304.8 m maximum |
Sensor current |
3 mA at 6V, 9 mA at 12V, 15 mA at 24V |
External supply current |
150 mA at 12V DC, 75 mA at 24V DC |
Power dissipation |
5.0 W (17.1 BTU/hr) |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Two counter channels, each with A, B, Z and gate inputs, which supports quadrature, index reset and a hardware gate.
100 kHz maximum count rate with a 2 ms minimum pulse width.
304.8 m of Belden 8761, the published cable allowance, is what makes a remote meter or encoder run practical.
Sensor current of 3 mA at 6V, 9 mA at 12V and 15 mA at 24V sets the load a field device has to drive.
150 mA at 12V DC or 75 mA at 24V DC is the module consumption at the two published supply points.
5.0 W (17.1 BTU/hr) is the dissipation, the same class as the very high speed counter.
0...55 deg C operating range — the card is for a heated cabinet.
The gate input is a hardware enable, so a batch stops at the count without a program instruction racing the pulse train.
Quadrature with Z reset lets the counter re-zero once per revolution rather than on a program command.
The 2 ms pulse width excludes fast encoders; above roughly 250 pulses per second per channel this is the wrong card.
Cable length is an electrical limit, not a suggestion: beyond 304.8 m the pulse edges arrive too slowly for the input filter.
That 304.8 m figure assumes Belden 8761, a shielded twisted pair; an unshielded cable of the same length will count induced noise as pulses.
Shielded twisted pair, shield at the panel, and A/B on separate pairs from the Z index.
One 24V sensor supply per channel group keeps a faulty sensor from taking the second channel down.
Gate wired to a maintained contact is the simple batch enable; a momentary button will pass a burst of counts.
Count verification against a mechanical register at commissioning is the quickest proof that the input filter and the pulse width are right.
Field power removed before insertion, following the FlexBus sequence in the publication.
Batch counting with a hardware gate at up to 100 kHz.
Remote encoder or meter runs up to 304.8 m on Belden 8761.
Not for registration at machine speed; the 1794-VHSC counts to 1 MHz with eight compare windows.
Not for 1...32 kHz analogue pickups; the 1794-IJ2 handles sine wave and wire-off detection.
How many channels has the 1794-ID2?
Two counter channels, each with A, B, Z and gate inputs.
What is the maximum count rate?
100 kHz, with a 2 ms minimum pulse width.
How long can the encoder cable be?
304.8 m on Belden 8761 or equivalent.
What current does the module draw?
150 mA at 12V DC or 75 mA at 24V DC.
What sensor current does it provide?
3 mA at 6V, 9 mA at 12V and 15 mA at 24V.
What is the operating temperature?
0...55 deg C.
1794-ID2 is a FLEX I/O specialty module for the 1794 system, documented here from the Rockwell specialty module technical data so that the input thresholds, the counting limits, the output ratings and the terminal base requirement are stated for this catalog number.
| Specification | Value |
|---|---|
| Catalog number | 1794-ID2, FLEX I/O 2 input pulse counter |
| Inputs | 2 counters, 4 inputs per counter: A, B, Z and G |
| Counting frequency | 100 kHz |
| Input pulse width | Each signal condition must be stable for at least 2 microseconds to be recognised |
| Supply voltage | 12 to 24V DC plus or minus 10 percent, 150 mA at 12V DC and 75 mA at 24V DC |
| On-state input | 26.4V DC maximum, 3 mA minimum at 6V DC, 9 mA nominal at 12V DC, 15 mA maximum at 24V DC |
| Off-state input | 3V DC maximum, minus 26.4V DC minimum |
| Flexbus current | 5 mA at 5V DC |
| Operating temperature | 0 to 55 degrees C |
| Source | 1794-TD017-EN-E FLEX I/O specialty modules |
Four inputs per counter, A, B, Z and G, on a two channel part is the detail that defines the wiring effort. A quadrature encoder with a marker pulse uses A, B and Z, and the gate input handles direction or an enable, so a two channel module with this input count is really a two axis counting card.
A hundred kilohertz of counting rate with a two microsecond minimum pulse is a modest specification by modern standards, and it is enough for most contact protected or proximity counting tasks where the signal conditioning in front of the module is the slow element.
These modules are judged on four figures: the maximum rate or count, the minimum pulse width or processing time, the input threshold with its sensing current, and the output rating with its protection behaviour. The table carries all four, and the notes explain where each of them limits the machine rather than the module.
Pulse width is the real bandwidth limit. A minimum pulse of a few microseconds defines how fast an input can toggle regardless of the nominal frequency, and an encoder with a fine line count at high speed will violate that before it violates the frequency rating.
Accuracy and resolution are quoted separately for a reason. A resolution of a hundredth of a percent with an accuracy of a few tenths of a percent means the display can show digits that the measurement does not justify, and a control loop tuned to those digits will chase noise.
The terminal base is part of the specification on these modules. The counter and frequency parts are documented on the TB3G family with the keyswitch at position one, and a base that lacks the sensing terminations will not provide the low level inputs the module is specified against.
Isolated output groups are a safety and noise measure rather than an electrical feature. Two isolated groups of one or two outputs allow separate field supplies and separate returns, which is what a counter module needs when it drives a valve on one circuit and a lamp on another.
Wire off detection is the diagnostic that saves a commissioning day. A small detect current through a shunt resistor proves the field circuit is closed before the machine runs, and losing that function by wiring without the shunt is a silent trade.
Sensing threshold and sensing level are two different engineering questions. One asks whether a 5 volt or a 24 volt signal crosses the threshold reliably, the other asks how much current the front end draws and whether a two wire sensor can supply it, and both appear in the same table for that reason.
Short circuit protection that latches off until power is cycled is a behaviour a maintenance team has to know. It protects the module, and it also means a field short stops the output until someone opens the panel, which is a commissioning note rather than a datasheet footnote.
A counter module counts edges, so mechanical contact bounce becomes counts. Debounce is either a filter setting or a hardware answer, and a panel that uses a dry contact on a fast counter without either will report counts that do not exist.
Filter selections are the answer to electrical noise, and they cost resolution. Off, ten microseconds, a hundred microseconds, a millisecond and ten milliseconds per channel group is a menu, and choosing a heavy filter to clean up a noisy encoder also caps the maximum frequency the channel can count.
Compare windows turn a counter into a cam controller. Eight windows tied to two physical outputs is a small motion controller built from a counter module, and the resolution of the windows is the resolution of the machine, not the resolution of the counter.
These modules draw only a few milliamps from the flexbus, and their field supplies are separate. A rail budget that charges them like discrete outputs will over provision the adapter, while a rail that forgets the field supply will find the module dead but the indicators healthy.
The maximum count value is a range statement, not a memory statement. A twenty four bit counter wraps at over sixteen million counts, and a machine that counts a fast pulse train for a week has to know exactly when that wrap happens and how the program handles it.
A frequency input module with gate channels measures direction as well as rate. The gate input establishes direction while the frequency input provides the pulse train, and that pairing is what allows a flow meter or an encoder to report signed rate rather than speed alone.
Allow for four field inputs per counter channel on the drawing, provide the separate field supply, and check the pulse width against the counting rate before the encoder is ordered.
The Allen-Bradley Flex I/O 1794 modules category groups the other catalog numbers, options and spare parts in the same range.