logo
Home ProductsAB FlexLogix I/O 1794

Allen Bradley PLC 1794-ID2 / 1794ID2

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1794-ID2 / 1794ID2

China Allen Bradley PLC 1794-ID2 / 1794ID2 supplier
Allen Bradley PLC 1794-ID2 / 1794ID2 supplier Allen Bradley PLC 1794-ID2 / 1794ID2 supplier Allen Bradley PLC 1794-ID2 / 1794ID2 supplier Allen Bradley PLC 1794-ID2 / 1794ID2 supplier Allen Bradley PLC 1794-ID2 / 1794ID2 supplier

Large Image :  Allen Bradley PLC 1794-ID2 / 1794ID2

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-ID2 / 1794ID2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $418.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-ID2 technical data PDF download FLEX I/O 1794-ID2 / 1794ID2 2-Channel Counter Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-ID2 counts two channels at up to 100 kHz with A, B, Z and gate inputs per channel, a 2 ms minimum pulse width, and a 304.8 m cable allowance on Belden 8761.

It sits between the frequency module and the very high speed counter: faster than a digital input with a timer, slower than a registration card, and with the gate input a batch application expects.

1794-IJ2 2-channel frequency input module, 1...32 kHz IN STOCK
1794-IJ2XT 2-channel frequency input module, extended temperature IN STOCK
1794-VHSC 2-axis very high speed counter, 1 MHz, 8 compare windows IN STOCK
1794-ID2 2-channel counter with A, B, Z and gate inputs IN STOCK
1794-IP4 4-channel counter module, 100 kHz IN STOCK

Product Specifications 1794-ID2 (PDF)
 Application
 FLEX I/O counter, 1794 terminal base
 Cat Num
 1794-ID2
 Brand Name
 Rockwell
 Channels
 2 counter channels
 Inputs per channel
 A, B, Z and gate
 Frequency
 100 kHz
 Minimum pulse width
 2 ms
 Cable
 Belden 8761 or equivalent, 304.8 m maximum
 Sensor current
 3 mA at 6V, 9 mA at 12V, 15 mA at 24V
 External supply current
 150 mA at 12V DC, 75 mA at 24V DC
 Power dissipation
 5.0 W (17.1 BTU/hr)
 Operating temperature
 0...55 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-ID2 original product photograph, wide view 1794-ID2 original product photograph, wide view 1794-ID2 original product photograph, wide view

Counting and inputs

Two counter channels, each with A, B, Z and gate inputs, which supports quadrature, index reset and a hardware gate.

100 kHz maximum count rate with a 2 ms minimum pulse width.

304.8 m of Belden 8761, the published cable allowance, is what makes a remote meter or encoder run practical.

Sensor current of 3 mA at 6V, 9 mA at 12V and 15 mA at 24V sets the load a field device has to drive.

Supply and heat

150 mA at 12V DC or 75 mA at 24V DC is the module consumption at the two published supply points.

5.0 W (17.1 BTU/hr) is the dissipation, the same class as the very high speed counter.

0...55 deg C operating range — the card is for a heated cabinet.

The gate input is a hardware enable, so a batch stops at the count without a program instruction racing the pulse train.

Application notes

Quadrature with Z reset lets the counter re-zero once per revolution rather than on a program command.

The 2 ms pulse width excludes fast encoders; above roughly 250 pulses per second per channel this is the wrong card.

Cable length is an electrical limit, not a suggestion: beyond 304.8 m the pulse edges arrive too slowly for the input filter.

That 304.8 m figure assumes Belden 8761, a shielded twisted pair; an unshielded cable of the same length will count induced noise as pulses.

Shielded twisted pair, shield at the panel, and A/B on separate pairs from the Z index.

Wiring practice

One 24V sensor supply per channel group keeps a faulty sensor from taking the second channel down.

Gate wired to a maintained contact is the simple batch enable; a momentary button will pass a burst of counts.

Count verification against a mechanical register at commissioning is the quickest proof that the input filter and the pulse width are right.

Field power removed before insertion, following the FlexBus sequence in the publication.

Where it fits

Batch counting with a hardware gate at up to 100 kHz.

Remote encoder or meter runs up to 304.8 m on Belden 8761.

Not for registration at machine speed; the 1794-VHSC counts to 1 MHz with eight compare windows.

Not for 1...32 kHz analogue pickups; the 1794-IJ2 handles sine wave and wire-off detection.

FAQ — 1794-ID2

How many channels has the 1794-ID2?

Two counter channels, each with A, B, Z and gate inputs.

What is the maximum count rate?

100 kHz, with a 2 ms minimum pulse width.

How long can the encoder cable be?

304.8 m on Belden 8761 or equivalent.

What current does the module draw?

150 mA at 12V DC or 75 mA at 24V DC.

What sensor current does it provide?

3 mA at 6V, 9 mA at 12V and 15 mA at 24V.

What is the operating temperature?

0...55 deg C.


Data sources. Technical values on this page come from Rockwell publication 1794-SG002 (FLEX I/O Selection Guide, Table 39) and 1794-IN093. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.