Product Details:
Payment & Shipping Terms:
|
The 1794-ID2 counts two channels at up to 100 kHz with A, B, Z and gate inputs per channel, a 2 ms minimum pulse width, and a 304.8 m cable allowance on Belden 8761.
It sits between the frequency module and the very high speed counter: faster than a digital input with a timer, slower than a registration card, and with the gate input a batch application expects.
| 1794-IJ2 | 2-channel frequency input module, 1...32 kHz | IN STOCK |
| 1794-IJ2XT | 2-channel frequency input module, extended temperature | IN STOCK |
| 1794-VHSC | 2-axis very high speed counter, 1 MHz, 8 compare windows | IN STOCK |
| 1794-ID2 | 2-channel counter with A, B, Z and gate inputs | IN STOCK |
| 1794-IP4 | 4-channel counter module, 100 kHz | IN STOCK |
Application |
FLEX I/O counter, 1794 terminal base |
Cat Num |
1794-ID2 |
Brand Name |
Rockwell |
Channels |
2 counter channels |
Inputs per channel |
A, B, Z and gate |
Frequency |
100 kHz |
Minimum pulse width |
2 ms |
Cable |
Belden 8761 or equivalent, 304.8 m maximum |
Sensor current |
3 mA at 6V, 9 mA at 12V, 15 mA at 24V |
External supply current |
150 mA at 12V DC, 75 mA at 24V DC |
Power dissipation |
5.0 W (17.1 BTU/hr) |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Two counter channels, each with A, B, Z and gate inputs, which supports quadrature, index reset and a hardware gate.
100 kHz maximum count rate with a 2 ms minimum pulse width.
304.8 m of Belden 8761, the published cable allowance, is what makes a remote meter or encoder run practical.
Sensor current of 3 mA at 6V, 9 mA at 12V and 15 mA at 24V sets the load a field device has to drive.
150 mA at 12V DC or 75 mA at 24V DC is the module consumption at the two published supply points.
5.0 W (17.1 BTU/hr) is the dissipation, the same class as the very high speed counter.
0...55 deg C operating range — the card is for a heated cabinet.
The gate input is a hardware enable, so a batch stops at the count without a program instruction racing the pulse train.
Quadrature with Z reset lets the counter re-zero once per revolution rather than on a program command.
The 2 ms pulse width excludes fast encoders; above roughly 250 pulses per second per channel this is the wrong card.
Cable length is an electrical limit, not a suggestion: beyond 304.8 m the pulse edges arrive too slowly for the input filter.
That 304.8 m figure assumes Belden 8761, a shielded twisted pair; an unshielded cable of the same length will count induced noise as pulses.
Shielded twisted pair, shield at the panel, and A/B on separate pairs from the Z index.
One 24V sensor supply per channel group keeps a faulty sensor from taking the second channel down.
Gate wired to a maintained contact is the simple batch enable; a momentary button will pass a burst of counts.
Count verification against a mechanical register at commissioning is the quickest proof that the input filter and the pulse width are right.
Field power removed before insertion, following the FlexBus sequence in the publication.
Batch counting with a hardware gate at up to 100 kHz.
Remote encoder or meter runs up to 304.8 m on Belden 8761.
Not for registration at machine speed; the 1794-VHSC counts to 1 MHz with eight compare windows.
Not for 1...32 kHz analogue pickups; the 1794-IJ2 handles sine wave and wire-off detection.
How many channels has the 1794-ID2?
Two counter channels, each with A, B, Z and gate inputs.
What is the maximum count rate?
100 kHz, with a 2 ms minimum pulse width.
How long can the encoder cable be?
304.8 m on Belden 8761 or equivalent.
What current does the module draw?
150 mA at 12V DC or 75 mA at 24V DC.
What sensor current does it provide?
3 mA at 6V, 9 mA at 12V and 15 mA at 24V.
What is the operating temperature?
0...55 deg C.