Product Details:
Payment & Shipping Terms:
|
The 1794-IC16 reads 16 sinking 48V DC inputs — the 48V DC variant of the 1794-IB16, for panels that run a 48V control rail instead of 24V.
One module covers a full 16-point group at 5 mA per point, so the field supply carries about 82 mA at nominal voltage on top of the device currents.
| 1794-IB8 | 8-point 24V DC sinking input module | IN STOCK |
| 1794-IB16 | 16-point 24V DC sinking input module | IN STOCK |
| 1794-IB32 | 32-point 24V DC sinking input module | IN STOCK |
| 1794-IB10XOB6 | 10 inputs / 6 sourcing outputs, 24V DC combo module | IN STOCK |
| 1794-IB16XOB16P | 16 inputs / 16 protected sourcing outputs combo module | IN STOCK |
| 1794-IB16D | 16-point diagnostic sinking input module | IN STOCK |
| 1794-IB16XT | 16-point 24V DC sinking input, extended temperature | IN STOCK |
| 1794-IB10XOB6XT | 10 inputs / 6 sourcing outputs, extended temperature | IN STOCK |
| 1794-IA8 | 8-point 120V AC input module | IN STOCK |
| 1794-IA16 | 16-point 120V AC input module | IN STOCK |
| 1794-IC16 | 16-point 48V DC sinking input module | IN STOCK |
| 1794-IG16 | 16-point 5V DC TTL input module | IN STOCK |
| 1794-IH16 | 16-point 125V DC sinking input module | IN STOCK |
| 1794-IM8 | 8-point 240V AC input module | IN STOCK |
| 1794-IM16 | 16-point 240V AC input module | IN STOCK |
| 1794-IV16 | 16-point 24V DC sourcing input module | IN STOCK |
| 1794-IV32 | 32-point 24V DC sourcing input module | IN STOCK |
Application |
FLEX I/O digital input, 48V DC |
Cat Num |
1794-IC16 |
Brand Name |
Rockwell |
Number of inputs |
16, nonisolated, sinking |
On-state voltage |
30V DC min, 48V DC nom, 60V DC max |
On-state current |
2.0 mA @ 30V, 5.0 mA @ 48V, 7.0 mA @ 60V |
Off-state voltage, max |
10V DC |
Input impedance |
11 k ohm nominal |
External supply |
48V DC nominal, 30...60V DC range |
Supply current |
51 mA @ 30V, 82 mA @ 48V, 107 mA @ 60V |
Terminal base |
1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
On-state 30...60V DC, 5.0 mA at 48V nominal, with 2.0 mA at the 30V threshold and 7.0 mA at 60V.
Off-state below 10V DC, 11 k ohm nominal input impedance, which sets the leakage a two-wire device may pass without being read as On.
16 sinking inputs, nonisolated, one group, with 16 yellow status indicators on the field side.
Keyswitch position 1 on the terminal base, as set out in publication 1794-IN105.
Inputs land on terminals A-0...A-15, with the 48V supply on C-35...C-50 and commons on B-17...B-32.
C-34...C-51 are internally connected, so the supply can be brought in once and distributed across the base.
3-wire devices also need the common terminal, 2-wire devices use input and supply only.
Daisy chain to the next base by jumpering C-51 to C-34 and B-33 to B-16.
51 mA at 30V, 82 mA at 48V, 107 mA at 60V is the module's own draw from the field supply.
The field devices add to that, and the base is limited to 10 A total through its terminals.
The 48V rail is not generated by the adapter, so a 48V supply is part of the panel design.
Fusing is external; the module has none.
48V DC control circuits carried over from older machine designs.
Longer cable runs where 48V tolerates more voltage drop than 24V.
Not a substitute for 125V DC; the 1794-IH16 covers that range.
Not isolated; the 1794-IA8I style isolated AC parts are a different family.
Retrofit panels with an existing 48V rail.
Machines mixing 24V logic and 48V field devices.
Not for 24V islands; the 1794-IB16 is the equivalent at 24V.
Not for extended temperature; 0...55 deg C only.
How many inputs has the 1794-IC16?
16 nonisolated sinking inputs.
What voltage range does it accept?
30...60V DC, with 48V DC nominal.
What is the on-state current?
5.0 mA at 48V DC, 2.0 mA at 30V and 7.0 mA at 60V.
Which terminal bases are used?
1794-TB3, 1794-TB3S, 1794-TB3K and 1794-TB3SK.
What is the operating temperature?
0...55 deg C.
Does the module supply the 48V rail?
No; a separate 48V supply feeds C-34 and the module draws 51 to 107 mA from it.
1794-IC16 is a digital DC input with 16 inputs in the FLEX I/O range, rated for 125V DC, sinking. It mounts on the 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK terminal base unit, which is ordered separately and is the part that actually carries the field terminals.
| Attribute | Value |
| Catalog number | 1794-IC16 |
| Module type | digital DC input |
| Points | 16 inputs |
| Electrical range | 125V DC, sinking |
| Terminal base unit | 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK |
| On-state input | 90V DC minimum, 125V DC nominal, 146V DC maximum, sinking |
| Off-state input | 20V DC maximum |
| On-state current | 2 mA at 125V DC, 3 mA maximum |
| Input impedance | 60 kOhm maximum |
| Power dissipation | 6 W at 146V DC |
| Operating temperature | -20 to +55 C |
Conformal coated variants carry a K suffix and exist because the same base can be asked to survive washdown, condensate, or corrosive atmosphere. Ordering the uncoated base and treating it in the field is not equivalent and does not carry the same published rating.
For a retrofit into an existing slice, the addressing is decided by position rather than by catalog number: FLEX I/O assigns the module its place in the rack by the order of the bases on the rail, so inserting a module in the middle shifts the addresses of everything to its right and requires the program to be re-checked.
FLEX I/O bases and modules are separate line items on a purchase order, and the price of getting that wrong is a second shipment: a module without its base cannot be installed, and a base of the wrong termination type cannot be reworked in the field because the module keys to the base family.
On the 32 point bases the common and voltage terminals are grouped in eight pairs rather than eighteen, which is why the 32 point digital modules can mix sinking and sourcing groups in one slice and why the terminal numbering on the drawing does not follow the 16 point pattern.
Any FLEX I/O position is a pair on the purchase order: one base, one module. Stocking modules without bases, or bases without the matching modules, produces a slice that cannot be commissioned, and the two part numbers are never interchangeable across the 8, 16 and 32 point families.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
Related models, options and spare parts for this range are listed in the Allen-Bradley Flex I/O 1794 modules category.