Allen Bradley PLC 1794-IC16 / 1794IC16

China Allen Bradley PLC 1794-IC16 / 1794IC16 supplier
Allen Bradley PLC 1794-IC16 / 1794IC16 supplier Allen Bradley PLC 1794-IC16 / 1794IC16 supplier Allen Bradley PLC 1794-IC16 / 1794IC16 supplier Allen Bradley PLC 1794-IC16 / 1794IC16 supplier Allen Bradley PLC 1794-IC16 / 1794IC16 supplier

Large Image :  Allen Bradley PLC 1794-IC16 / 1794IC16

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-IC16 / 1794IC16

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $149.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1794-IC16 technical data PDF download FLEX I/O 1794-IC16 / 1794IC16 16-Point 48V DC Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-IC16 reads 16 sinking 48V DC inputs — the 48V DC variant of the 1794-IB16, for panels that run a 48V control rail instead of 24V.

One module covers a full 16-point group at 5 mA per point, so the field supply carries about 82 mA at nominal voltage on top of the device currents.

1794-IB8 8-point 24V DC sinking input module IN STOCK
1794-IB16 16-point 24V DC sinking input module IN STOCK
1794-IB32 32-point 24V DC sinking input module IN STOCK
1794-IB10XOB6 10 inputs / 6 sourcing outputs, 24V DC combo module IN STOCK
1794-IB16XOB16P 16 inputs / 16 protected sourcing outputs combo module IN STOCK
1794-IB16D 16-point diagnostic sinking input module IN STOCK
1794-IB16XT 16-point 24V DC sinking input, extended temperature IN STOCK
1794-IB10XOB6XT 10 inputs / 6 sourcing outputs, extended temperature IN STOCK
1794-IA8 8-point 120V AC input module IN STOCK
1794-IA16 16-point 120V AC input module IN STOCK
1794-IC16 16-point 48V DC sinking input module IN STOCK
1794-IG16 16-point 5V DC TTL input module IN STOCK
1794-IH16 16-point 125V DC sinking input module IN STOCK
1794-IM8 8-point 240V AC input module IN STOCK
1794-IM16 16-point 240V AC input module IN STOCK
1794-IV16 16-point 24V DC sourcing input module IN STOCK
1794-IV32 32-point 24V DC sourcing input module IN STOCK

Product Specifications 1794-IC16 (PDF)
 Application
 FLEX I/O digital input, 48V DC
 Cat Num
 1794-IC16
 Brand Name
 Rockwell
 Number of inputs
 16, nonisolated, sinking
 On-state voltage
 30V DC min, 48V DC nom, 60V DC max
 On-state current
 2.0 mA @ 30V, 5.0 mA @ 48V, 7.0 mA @ 60V
 Off-state voltage, max
 10V DC
 Input impedance
 11 k ohm nominal
 External supply
 48V DC nominal, 30...60V DC range
 Supply current
 51 mA @ 30V, 82 mA @ 48V, 107 mA @ 60V
 Terminal base
 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK
 Operating temperature
 0...55 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-IC16 original product photograph, wide view 1794-IC16 original product photograph, wide view 1794-IC16 original product photograph, wide view

Input characteristics

On-state 30...60V DC, 5.0 mA at 48V nominal, with 2.0 mA at the 30V threshold and 7.0 mA at 60V.

Off-state below 10V DC, 11 k ohm nominal input impedance, which sets the leakage a two-wire device may pass without being read as On.

16 sinking inputs, nonisolated, one group, with 16 yellow status indicators on the field side.

Keyswitch position 1 on the terminal base, as set out in publication 1794-IN105.

Wiring

Inputs land on terminals A-0...A-15, with the 48V supply on C-35...C-50 and commons on B-17...B-32.

C-34...C-51 are internally connected, so the supply can be brought in once and distributed across the base.

3-wire devices also need the common terminal, 2-wire devices use input and supply only.

Daisy chain to the next base by jumpering C-51 to C-34 and B-33 to B-16.

Supply budget

51 mA at 30V, 82 mA at 48V, 107 mA at 60V is the module's own draw from the field supply.

The field devices add to that, and the base is limited to 10 A total through its terminals.

The 48V rail is not generated by the adapter, so a 48V supply is part of the panel design.

Fusing is external; the module has none.

Application

48V DC control circuits carried over from older machine designs.

Longer cable runs where 48V tolerates more voltage drop than 24V.

Not a substitute for 125V DC; the 1794-IH16 covers that range.

Not isolated; the 1794-IA8I style isolated AC parts are a different family.

Where it fits

Retrofit panels with an existing 48V rail.

Machines mixing 24V logic and 48V field devices.

Not for 24V islands; the 1794-IB16 is the equivalent at 24V.

Not for extended temperature; 0...55 deg C only.

FAQ — 1794-IC16

How many inputs has the 1794-IC16?

16 nonisolated sinking inputs.

What voltage range does it accept?

30...60V DC, with 48V DC nominal.

What is the on-state current?

5.0 mA at 48V DC, 2.0 mA at 30V and 7.0 mA at 60V.

Which terminal bases are used?

1794-TB3, 1794-TB3S, 1794-TB3K and 1794-TB3SK.

What is the operating temperature?

0...55 deg C.

Does the module supply the 48V rail?

No; a separate 48V supply feeds C-34 and the module draws 51 to 107 mA from it.


Data sources. Technical values on this page come from Rockwell publication 1794-IN105 (FLEX I/O 48V DC Digital Input and Output Modules). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

Where the 1794-IC16 sits in the FLEX I/O range

1794-IC16 is a digital DC input with 16 inputs in the FLEX I/O range, rated for 125V DC, sinking. It mounts on the 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK terminal base unit, which is ordered separately and is the part that actually carries the field terminals.

AttributeValue
Catalog number1794-IC16
Module typedigital DC input
Points16 inputs
Electrical range125V DC, sinking
Terminal base unit1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK
On-state input90V DC minimum, 125V DC nominal, 146V DC maximum, sinking
Off-state input20V DC maximum
On-state current2 mA at 125V DC, 3 mA maximum
Input impedance60 kOhm maximum
Power dissipation6 W at 146V DC
Operating temperature-20 to +55 C

Conformal coated variants carry a K suffix and exist because the same base can be asked to survive washdown, condensate, or corrosive atmosphere. Ordering the uncoated base and treating it in the field is not equivalent and does not carry the same published rating.

For a retrofit into an existing slice, the addressing is decided by position rather than by catalog number: FLEX I/O assigns the module its place in the rack by the order of the bases on the rail, so inserting a module in the middle shifts the addresses of everything to its right and requires the program to be re-checked.

FLEX I/O bases and modules are separate line items on a purchase order, and the price of getting that wrong is a second shipment: a module without its base cannot be installed, and a base of the wrong termination type cannot be reworked in the field because the module keys to the base family.

On the 32 point bases the common and voltage terminals are grouped in eight pairs rather than eighteen, which is why the 32 point digital modules can mix sinking and sourcing groups in one slice and why the terminal numbering on the drawing does not follow the 16 point pattern.

Any FLEX I/O position is a pair on the purchase order: one base, one module. Stocking modules without bases, or bases without the matching modules, produces a slice that cannot be commissioned, and the two part numbers are never interchangeable across the 8, 16 and 32 point families.

Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.