Product Details:
Payment & Shipping Terms:
|
The 1794-CJC2 supplies two cold junction compensation parts, the replaceable element on a FLEX I/O temperature base.
The temperature bases carry two CJC sets for the 1794-IT8 and 1794-IRT8, so this kit is a one-base replacement or a spares line for a maintenance crib.
| 1794-PS3 | 120/220V AC power supply, 24V DC 3.0 A | IN STOCK |
| 1794-PS13 | 120/220V AC power supply, 24V DC 1.3 A | IN STOCK |
| 1794-CE1 | 0.3 m (1 ft) extender cable for FLEX I/O | IN STOCK |
| 1794-CE3 | 0.9 m (3 ft) extender cable for FLEX I/O | IN STOCK |
| 1794-NM1 | panel mounting kit with 18 screws | IN STOCK |
| 1794-N2 | empty slot filler module, no electronics | IN STOCK |
| 1794-CJC2 | cold junction compensation kit, two parts | IN STOCK |
| 1794-LBL | label kit with die-cut sheet and five labels | IN STOCK |
Application |
Replacement cold junction compensation for FLEX I/O temperature bases |
Cat Num |
1794-CJC2 |
Brand Name |
Rockwell |
Contents |
Two cold junction compensation parts |
Fits |
1794-TB3T, 1794-TB3TK, 1794-TB3TS, 1794-TB3TSK |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Two cold junction compensation parts, the sensing element at the terminal block where the thermocouple wire lands.
Fits the temperature bases: 1794-TB3T, TB3TK, TB3TS and TB3TSK, each of which carries two sets.
Replaceable rather than soldered, so a drifted junction is a part swap.
The K suffix denotes the coated variant of the metal parts.
Cold junction compensation corrects for the terminal temperature, which is where the thermocouple actually terminates.
A drifted CJC reads as a temperature offset across every channel on the card, not as a random error.
Replacing both sets at once keeps the two halves of the base matched.
No recalibration of the module is implied by the accessory listing.
Spare parts for thermocouple islands, where a CJC failure stops a loop.
Base refurbishment when a coated base is reused.
Not a thermocouple; it does not include sensors or wire.
Not for the IR8; that module uses the ground terminals, not CJC sets.
One kit covers one base at two parts.
Count bases, not channels, when stocking spares.
1794-TB3T and 1794-TB3TK are cage clamp; the TS versions are spring.
Publication 1794-SG002 lists the kit in the accessory section.
Thermocouple and RTD islands with IT8 or IRT8 cards.
Maintenance cribs for plants with several temperature bases.
Not for analog voltage or current inputs; they do not use CJC.
Not for -XT upgrades on their own; the base and module coatings still matter.
What is in the 1794-CJC2 kit?
Two cold junction compensation parts.
Which bases does it fit?
1794-TB3T, 1794-TB3TK, 1794-TB3TS and 1794-TB3TSK.
How many sets does a temperature base carry?
Two.
Why replace a CJC?
A drifted junction offsets every channel on the card.
Is it used with the 1794-IR8?
No; the IR8 relies on the base ground terminals instead.
How many kits per base?
One kit, containing both parts.
1794-CJC2 is a cold junction compensator kit with two compensators per kit in the FLEX I/O range, rated for thermocouple mode cold junction compensation. It mounts on the 1794-TB3T, 1794-TB3TK, 1794-TB3TS or 1794-TB3TSK terminal base unit, which is ordered separately and is the part that actually carries the field terminals.
| Attribute | Value |
| Catalog number | 1794-CJC2 |
| Module type | cold junction compensator kit |
| Points | two compensators per kit |
| Electrical range | thermocouple mode cold junction compensation |
| Terminal base unit | 1794-TB3T, 1794-TB3TK, 1794-TB3TS or 1794-TB3TSK |
| Contents | A kit holds two compensators |
| Supply | One kit is shipped with the 1794-IT8 and with the 1794-IRT8, additional ones are ordered separately as 1794-CJC2 |
| Why it matters | Thermocouple readings are referenced to the cold junction at the terminal base, and the compensator is what makes that reference a measured value rather than the module terminal temperature |
Conformal coated variants carry a K suffix and exist because the same base can be asked to survive washdown, condensate, or corrosive atmosphere. Ordering the uncoated base and treating it in the field is not equivalent and does not carry the same published rating.
Temperature class is written per module and per base, and the lower of the two governs the slice. A 70 C base carrying a 55 C module is a 55 C slice, which is why the extended temperature modules exist as a matched set rather than as an upgrade to one part of the pair.
One point about the 24V DC digital slices that catches panel builders: the adapter supplies the field power for the modules on its own 24V output, and that output is current limited. On a 1794-ADN the supply output is 450 mA at 24V, so a slice of 16 point DC modules can exhaust the adapter before the cabinet is half filled, and a separate field supply has to be introduced rather than assumed.
On the 32 point bases the common and voltage terminals are grouped in eight pairs rather than eighteen, which is why the 32 point digital modules can mix sinking and sourcing groups in one slice and why the terminal numbering on the drawing does not follow the 16 point pattern.
Any FLEX I/O position is a pair on the purchase order: one base, one module. Stocking modules without bases, or bases without the matching modules, produces a slice that cannot be commissioned, and the two part numbers are never interchangeable across the 8, 16 and 32 point families.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
Related models, options and spare parts for this range are listed in the Allen-Bradley Flex I/O 1794 modules category.