Product Details:
Payment & Shipping Terms:
|
The 1794-CE3 is the 0.9 m extender cable — the same function as the 1794-CE1 across three times the distance.
It is the choice when the second row of the island sits in another compartment or below a duct rather than immediately beside the first.
| 1794-PS3 | 120/220V AC power supply, 24V DC 3.0 A | IN STOCK |
| 1794-PS13 | 120/220V AC power supply, 24V DC 1.3 A | IN STOCK |
| 1794-CE1 | 0.3 m (1 ft) extender cable for FLEX I/O | IN STOCK |
| 1794-CE3 | 0.9 m (3 ft) extender cable for FLEX I/O | IN STOCK |
| 1794-NM1 | panel mounting kit with 18 screws | IN STOCK |
| 1794-N2 | empty slot filler module, no electronics | IN STOCK |
| 1794-CJC2 | cold junction compensation kit, two parts | IN STOCK |
| 1794-LBL | label kit with die-cut sheet and five labels | IN STOCK |
Application |
FLEX I/O backplane extender cable |
Cat Num |
1794-CE3 |
Brand Name |
Rockwell |
Length |
0.9 m (3 ft) |
Use |
One cable per system, between any modules or adapter and module |
Purpose |
Splits the system into two rows or changes horizontal to vertical |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
0.9 m (3 ft) of backplane extension, one cable per system in the documented two-row layout.
Installed between any two modules or between the adapter and a module.
Same electrical function as the 1794-CE1, only longer.
Publication 1794-IN012 covers the cable and the layout diagram.
The two sections are separate DIN rail runs, each with its own 25 mm air space.
Chassis grounding is per rail section, not carried through the cable.
The backplane still needs one end cap per system, with both ends of the split capped.
Longer cable means more slack to manage; support it rather than letting it hang.
Two-compartment panels where the island must continue past a partition.
Vertical runs below or above the main rail.
Not for tight layouts; the 1794-CE1 leaves less slack.
Not a substitute for a second adapter when the run exceeds the cable.
1794-CE3: 0.9 m (3 ft).
1794-CE1: 0.3 m (1 ft).
One per system in the recommended arrangement.
Both cables are passive extenders for the backplane bus.
Split panels with a real distance between the two rail runs.
Machine frames where the I/O follows the mechanics.
Not for outdoor runs; the cable is inside the enclosure.
Not for high-vibration unsupported spans; secure it.
How long is the 1794-CE3?
0.9 m (3 ft).
How many are used per system?
One, per the selection guide.
Where is it installed?
Between any two modules, or between the adapter and a module.
What does it enable?
A two-row layout, or horizontal to vertical rearrangement.
Is there a shorter version?
Yes, the 1794-CE1 at 0.3 m.
Does it carry chassis ground?
No; each rail section needs its own ground path.
1794-CE3 is a 1794 FLEX I/O 0.9 m flexbus extender cable, described here from the Rockwell FLEX I/O selection guide and the related publication so that the identity, the published rating and the compatibility statement are on the page for this catalog number.
| Specification | Value |
|---|---|
| Catalog number | 1794-CE3, FLEX I/O 3 ft extender cable |
| Length | 0.9 m, 3 ft |
| Function | Connects between any module, or between an adapter and a module, to split the system into two rows or into horizontal and vertical sections |
| Quantity rule | One extender cable per system, never more than one |
| Temperature rating | 0 to 60 degrees C |
| UPC | 612598173617 |
| Country of origin | China |
| Compatible systems | 1794 FLEX I/O, FLEX Ex I/O, FLEX I/O-XT |
| Source | 1794-SG002D-EN-P selection guide, and the manufacturer product record for the UPC and temperature rating |
Nine hundred millimetres buys a real two row layout: two full eight module groups side by side in a wide enclosure, or a horizontal and a vertical section with space for wiring between them. It is the same part family as the one foot cable, with the same one per system rule.
The rule is the same for both lengths for a reason. The flexbus is a timing path, and a second extender in series inserts a second set of connectors into that path. Two rows and one cable is the supported configuration; three rows is not a documented layout at all.
This page states only what the Rockwell FLEX I/O documentation publishes for 1794-CE3: the catalog identity, the published rating or dimension, the compatibility statement and the source publication. Where the manufacturer does not publish a figure, the page says so instead of estimating one.
A filler is not a spare slot. Some integrators install a filler to reserve capacity for a later expansion, and that works only if the adapter was sized for the eventual module count at commissioning time, not at expansion time.
The extender cable rule is one per system, not one per row. A second extender in series breaks the flexbus timing assumptions the adapter was designed around, so the two row layout is a one cable layout, and a three row layout is not supported at all.
Labels matter more than they look. A terminal base that is not marked with its slot and its module type turns every future maintenance visit into a wire tracing exercise, which is exactly what the label kit exists to prevent.
Accessory part numbers are frequently the difference between a system that ships and a system that waits. A missing extender cable is a one week delay on a panel that is otherwise complete, and the order of magnitude of that delay belongs in the planning conversation.
A dummy filler module exists because an empty terminal base is an open slot in the flexbus chain. The filler carries no electronics, and its whole job is mechanical and documentation: the rail is complete, the slot is accounted for, and the drawing shows an intentional gap rather than a missing part.
Country of origin and part number structure belong on the page because procurement asks. A conformally coated variant and a standard variant share the same mechanical drawing and differ in the suffix, which is the kind of detail that only shows up at goods receipt.
Accessories are where a FLEX system stops being a catalog page and becomes a panel. The rail, the extender cable, the mounting screws and the filler module all change the drawing, and none of them appear in the module data sheet that the integrator reads first.
Screws in a mounting kit are a count, not a suggestion. Two for the adapter and two for each module means the kit covers a full eight module group, and a ninth module requires either a second kit or a sourced screw, which is a purchasing detail worth stating.
The flexbus connector is the fragile part of the assembly. It is pushed to the left to connect and retracted to disconnect, and a base installed with the connector partly extended will produce intermittent I/O that survives a power cycle and reappears under vibration.
A right angle split between horizontal and vertical orientation is the real reason the extender exists. Mounting the adapter horizontally in a shallow enclosure and the modules vertically in a deeper section is a mechanical decision that the cable makes possible without a second adapter.
Temperature ratings on a passive accessory are inherited from the materials. A cable rated to sixty degrees limits the panel interior temperature just as firmly as a module rated to fifty five, and a hot enclosure will fail the cable before it fails the electronics.
Every accessory on this page is sourced from the same FLEX selection guide that specifies the adapters and the terminal bases, which means the compatibility statement is the manufacturer statement rather than a distributor inference.
Panel mounting without DIN rail is a common requirement in machine tools exported to regions where the rail is not standard, and the mounting kit with its screws is cheaper than a rail plus the labour to fit it.
One cable per system, and the longer length buys the spacing between the rows rather than a third row.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley Flex I/O 1794 modules category.